DC Voltage Control and Power-Sharing of Multi-Terminal DC Grids Based on Optimal DC Power Flow and Flexible Voltage Droop Strategy

Authors

Abstract:

This paper develops an effective control framework for DC voltage control and power-sharing of multi-terminal DC (MTDC) grids based on an optimal power flow (OPF) procedure and the voltage-droop control. In the proposed approach, an OPF algorithm is executed at the secondary level to find optimal reference of DC voltages and active powers of all voltage-regulating converters. Then, the voltage droop characteristics of voltage-regulating converters, at the primary level, are tuned based on the OPF results such that the operating point of the MTDC grid lies on the voltage droop characteristics. Consequently, the optimally-tuned voltage droop controller leads to the optimal operation of the MTDC grid. In case of variation in load or generation of the grid, a new stable operating point is achieved based on the voltage droop characteristics. By execution of a new OPF, the voltage droop characteristics are re-tuned for optimal operation of the MTDC grid after the occurrence of the load or generation variations. The results of simulation on a grid inspired by CIGRE B4 DC grid test system demonstrate efficient grid performance under the proposed control strategy.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Flexible Control of Power Flow in Multiterminal DC Grids Using DC-DC Converter

This paper proposes an efficient control framework that utilizes de-de converters to achieve flexible power flow control in multiterminal de (MTDC) grids. The de-de converter employed in this paper is connected in cascade with the de transmission line, and is therefore named cascaded power flow controller (CPFC). In this paper, a two-layer control strategy is developed for the operation and con...

full text

A DC Voltage Control Strategy for Active Power Filter

Abstract: Active Power Filter (APF) is capable of changing the size and frequency of harmonics as well as changes in reactive power compensation. It is important to control the stability of the DC-link capacitor voltage stability for it. For DC voltage controls of APF, there are two important achievements. First, it is indicated that the control of DC voltage directly affects the compensation p...

full text

Voltage Control and Load Sharing in a DC Islanded Microgrid Based on Disturbance Observer

Increasing DC loads along with DC nature of distributed energy resources (DERs) raises interest to DC microgrids. Conventional droop/non-droop power-sharing in microgrids suffers from load dependent voltage deviation, slow transient response, and requires the parameters of the loads, system and DERs connection status. In this paper, a new nonlinear decentralized back-stepping control strategy f...

full text

High-Frequency Soft-Switching DC-DC Converters for Voltage and Current DC Power Sources

The paper presents soft switching PWM DC-DC converters using power MOSFETs and IGBTs. The attention is focused mainly on the full-bridge converters suitable for high power applications. The properties of the PWM converters are described in comparison to other categories of soft switching converters. An overview of the switching techniques using in the DC-DC converters is included. Consideration...

full text

Mathematical Study of Very High Voltage Power Networks I: The Optimal DC Power Flow Problem

The optimal power ow problem consists in setting the voltage and power delivered at the nodes of an electrical network, in order to minimize the loss of power over the lines. This paper is the rst of a series dedicated to the mathematical study of this problem, based on an asymptotic analysis, in which the small parameter is the inverse of the reference voltage of the network. We call this sche...

full text

High voltage gain DC-DC resonant converter

In this paper, a DC-DC resonant converter with high voltage gain and small size is studied. To reduce the size and weight of this converter, the operating frequency should be as high as possible. In this research, the frequency changes from 120 to 200 kHz. Due to the high operating frequency, it is necessary to reduce the switching losses using soft switching methods. Resonant converters are su...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 11  issue 2

pages  137- 144

publication date 2015-06

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023