Covid-19 manifestation on Tl-201 myocardial perfusion SPECT/CT

Authors

  • Elham Kalantari Department of Pulmonology, Isfahan University of Medical Science, Isfahan, Iran
  • Forough Kalantari Department of Nuclear Medicine, Jam Hospital, Tehran, Iran|Department of Nuclear Medicine, Rasoul Akaram Hospital, Iran University of Medical Sciences, Tehran, Iran
  • Mohsen Beheshti Department of Nuclear Medicine, Jam Hospital, Tehran, Iran|Department of Nuclear Medicine, University Hospital RWTH, Aachen, Germany
  • Nahid Yaghoobi Department of Nuclear Medicine, Rajaie Cardiovascular Medical and Research Center, Iran University of Medical sciences, Tehran, Iran
Abstract:

A 67 years old woman was referred to nuclear medicine center for myocardial perfusion imaging (MPI) for assessment of ischemic heart dieses (IHD).She had a history of atypical chest pain and dyspnea since about 10 days before admission. The MPI SPECT/CT was performed by stress/redistribution Tl-201 protocol. MPI was interpreted as relatively good coronary flow with no appreciable stress induced ischemia. SPECT-CT images revealed multifocal, bilateral and peripheral ground-glass opacities in lungs with subtle background uptake of Tl-201. Considering Covid-19 outbreak, the first diagnosis based on chest CT was Covid-19. This case emphasizing importance of attention to non-cardiac findings in patients undergoing myocardial perfusion imaging, especially review of lung window images in SPECT/CT protocols in the era of covid-19.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Serum caffeine levels after 24-hour abstention: clinical implications on dipyridamole (201)Tl myocardial perfusion imaging.

BACKGROUND Caffeine binds to the A2 receptors and inhibits adenosine's action of vasodilation or dipyridamole-induced vasodilation. Patients scheduled for (201)Tl myocardial perfusion using pharmacologic stress with dipyridamole or adenosine are advised to abstain from caffeine for 24 h before the test. This article reports on the residual serum caffeine levels of 36 patients after 24-h caffein...

full text

Thallium-201 Myocardial Perfusion Imaging

The sensitivity of myocardial perfusion imaging (MPI) using thallium-201 injected both at rest and during peak exercise was compared to simultaneously recorded 12 lead electrocardiography (ECG) for the detection of transient ischemia in 20 normal subjects and 63 patients with coronary artery disease (CAD). No significant perfusion defects or ECG changes were seen on either the rest or exercise ...

full text

Twenty four hour imaging delay improves viability detection by Tl - 201 myocardial perfusion

Objective: Since twenty-four-hour imaging by Tl-201 myocardial perfusion scintigraphy has been introduced as an effective additional procedure, the aim of this study was to compare this method’s result with only rest redistribution procedure in the diagnosis of myocardial viability. Methods: Thirty patients (Seven female, 23 male; mean: 59.8 ± 10.7, 55.8-63.8 years old) with diagnosis of corona...

full text

Twenty four hour imaging delay improves viability detection by Tl-201 myocardial perfusion scintigraphy

OBJECTIVE Since twenty-four-hour imaging by Tl-201 myocardial perfusion scintigraphy has been introduced as an effective additional procedure, the aim of this study was to compare this method's result with only rest redistribution procedure in the diagnosis of myocardial viability. METHODS Thirty patients (Seven female, 23 male; mean: 59.8 ± 10.7, 55.8-63.8 years old) with diagnosis of corona...

full text

Thallium-201 for myocardial imaging. Relation of thallium-201 to regional myocardial perfusion.

Following intravenous administration, the myocardial concentration of tracer thallium-201, potassium-43, and rubidium-81 were determined in mice; thallium was present in the greatest concentration in the myocardium (2.08% compared 1.25% for potassium and 1.15% for rubidium at 10 minutes). The regional myocardial distribution of thallium-201 was determined in dogs under conditions of normal flow...

full text

Myocardial perfusion SPECT: Perfusion quantification

Different software tools for quantification of myocardial perfusion SPECT (MPS) studies are routinely used. Several perfusion parameters can be computed automatically.  Interpretation of the MPS should start with visual inspection of the rotating planar images, visual analysis of reconstructed SPECT slices and then quantitative analysis to confirm the visual impression. Quantification should be...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 29  issue 1

pages  32- 34

publication date 2021-01-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023