Comparison of Working Length Determination Using Apex Locator and Conventional Radiography in Curved Canals-an In Vitro Study
Authors
Abstract:
Introduction: The exact measurement of the root canal length is of great importance in root canal therapy. Although, determination of the root canal length through radiography is the most common method, recently electronic apex locators are being used to determine working length and decrease the number of radiographs. The purpose of this study was to compare the accuracy of an electronic apex locator (Root ZX) with conventional radiography to determine the working length of curved mandibular molars. Materials and methods: 35 intact mandibular first molars with rote curve above 10° were selected. The access cavity was prepared and the root canal length was measured using apex locator (Root ZX) and conventional radiography. Data was analyzed by using the paired-sample t-test.(P<0.05) Results: The working lengths measured by apex locater were equal to the actual working lengths in 42.86%, 0.5-1 mm shorter in 31.43%, and 0.5 mm longer in 25.71%. The working lengths measured by radiography were equal to the actual working length in 51.14%, 0.5-1mm shorter in 39.99% and 0.5mm longer in 2.86%. There was no significant difference between these two methods in the measurement of the working length (p=0.951). Conclusion: The apex Locator and conventional radiography were equally effective in determining of the working length of the curved canals.
similar resources
comparison of working length determination using apex locator and conventional radiography in curved canals-an in vitro study
introduction: the exact measurement of the root canal length is of great importance in root canal therapy. although, determination of the root canal length through radiography is the most common method, recently electronic apex locators are being used to determine working length and decrease the number of radiographs. the purpose of this study was to compare the accuracy of an electronic apex l...
full textComparison of working length determination using apex locator, conventional radiography and radiovisiography: an in vitro study.
AIM The purpose of this study was to compare the working length determination done using three methods, namely, apex locator (Foramatron D-10, Parkell), radiovisiography (Planmeca) and conventional radiography (Prostyle intra, Planmeca). MATERIALS AND METHODS In this experiment, to determine the working length, 35 single-rooted teeth were selected and each tooth was subjected to all the three...
full textIn Vitro Comparative Study of the Working Length Determination with Radiovisiography and Conventional Radiography in Dilacerated Canals
Introduction: The aim of this study was to compare digital and conventional radiography in determining the working length of dilacerated canals.Methods: Thirty nine human extracted single-rooted teeth with root curvature more than 35 degrees were included in this study. After access preparation, a file was inserted into the canal and advanced until the file tip was visualized at the foramen. Wi...
full texta comparison between the raypex5 apex locator and conventional radiography for determining working length of straight and curved canals
introduction: the purpose of this in vitro study was to compare the accuracy of the new electronic apex locator raypex5 with radiography for working length determination of straight and curved root canals. materials and methods: twenty straight and single canals of maxillary central teeth and twenty curved mesiobuccal canals of mandibular molar teeth were used. access cavities were prepared and...
full textevaluation of conventional radiography and an electronic apex locator in determining the working length in c-shaped canals
introduction: the purpose of this in vitro study was to compare the accuracy of working length determination using the apex locator versus conventional radiography in c-shaped canals. methods and materials: after confirming the actual c-shaped anatomy using cone-beam computed tomography (cbct), 22 extracted c-shaped mandibular second molars were selected and decoronated at the cemento-enamel ju...
full textEvaluation of Conventional Radiography and an Electronic Apex Locator in Determining the Working Length in C-shaped Canals
INTRODUCTION The purpose of this in vitro study was to compare the accuracy of working length determination using the apex locator versus conventional radiography in C-shaped canals. METHODS AND MATERIALS After confirming the actual C-shaped anatomy using cone-beam computed tomography (CBCT), 22 extracted C-shaped mandibular second molars were selected and decoronated at the cemento-enamel ju...