Comparison of two radiation techniques in breast boost delivery

Authors

  • Danial Seifi Makrani Department of Biochemistry and Biophysics, Faculty of Medicine, Mazandaran University of Medical Sciences, Sari, Iran.
  • Tayyeb Pourfallah Department of Biochemistry and Biophysics, Faculty of Medicine, Mazandaran University of Medical Sciences, Sari, Iran.
Abstract:

Introduction: In the treatment of breast cancer, breast conserving surgery (BCS) and whole breast irradiation is a usual technique. The influence of lumpectomy boost following breast radiotherapy is apparent, but there are different delivery methods. This work intended to compare the dosimetric parameters of electron beams and photon beams for boosting irradiation in breast cancer patients who experienced breast-conserving surgery and whole- breast irradiation.   Materials and Methods: In this study we compared plans for electron beams and photon beams boost irradiation for 32 breast cancer patients who experienced breast-conserving surgery. Each patient was firstly treated by whole breast irradiation (45 Gy in 25 fractions) and then followed by lumpectomy boost (10 Gy in 5 fractions) with either electron beam therapy or with photon, 16 patients in each group. The organs at risk (OAR) involved the coronary arteries, lungs, and skin. For dosimetric comparison, conformity index (CI), homogeneity index (HI), uniformity index (UI) and dose-volume parameters for the planning target volume (PTV), and OAR were studied.   Results: From 2015 to 2017, thirty-two (32) patients enrolled the study. There were 11 patients (35%) with stage IIA, 14 patients (44%) with stage IIB and 7 patients (21%) with stage IIIA. Median age was 52 years (range 42-73). In the case of CI and HI significant differences were found in approval of the photon boost but in the evaluation of UI no major difference was noticed between two techniques. For PTV coverage of V95% and V107% the photon plans was superior to that of electron plans. About OAR sparing, the photon beam reduced the high-dose volume with cost of an increased low-dose volume. The high-dose volumes increased with electron plans.   Conclusion: Data show that photon boost irradiation provides better coverage to the tumor bed and improved dosimetric parameters compared to electron boost, considered the fact that PTV coverage and OAR sparing were superior with photons. It can be conclude that in centers where electron beam therapy is not presented, photon beam can be used efficiently for lumpectomy boost

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Breast Boost: Are We Missing the Target? A Dosimetric Comparison of Two Boost Techniques

Received July 19, 2002; revision received September 16, 2002; accepted September 24, 2002. BACKGROUND. Randomized trials have shown improved local control with the use of a breast boost for patients given breast-conserving treatment for breast carcinoma. Although the use of a breast boost is routine practice, no standard technique has been established. The authors compared the commonly used cli...

full text

Comparison of breast simultaneous integrated boost (SIB) radiotherapy techniques

PURPOSE To dosimetrically evaluate different breast SIB techniques with respect to target coverage and organs at risk (OARs) doses. METHODS Four IMRT techniques were compared in 12 patients. Three techniques employ tangential whole breast irradiation with either two coplanar fields (T-2F), or four non-coplanar fields (T-NC), or one Volumetric Modulated Arc Therapy (T-VMAT) for the boost volum...

full text

Breast conserving treatment for breast cancer: dosimetric comparison of different non-invasive techniques for additional boost delivery

BACKGROUND Today it is unclear which technique for delivery of an additional boost after whole breast radiotherapy for breast conserved patients should be state of the art. We present a dosimetric comparison of different non-invasive treatment techniques for additional boost delivery. METHODS For 10 different tumor bed localizations, 7 different non-invasive treatment plans were made. Dosimet...

full text

Evaluation of two tomotherapy-based techniques for the delivery of whole-breast intensity-modulated radiation therapy.

PURPOSE To evaluate two different techniques for whole-breast treatments delivered using the Hi-ART II tomotherapy device. METHODS AND MATERIALS Tomotherapy uses the standard rotational helical delivery. Topotherapy uses a stationary gantry while delivering intensity-modulated treatments. CT scans from 5 breast cancer patients were used. The prescription dose was 50.4 Gy. RESULTS On average...

full text

Comparison of forward intensity modulated radiation therapy and two field tangential wedged beam techniques in radiotherapy of breast cancer: dosimetric and radiobiologic study

Introduction: This study aims to compare the dose delivery parameters and radiobiologic model prediction of Tumor Control Probability (TCP) of the FIMRT technique compared with rectangular two tangential wedged fields (2FW) in the treatment of breast cancer. Furthermore, reduction of the heart and lung dose in the FIMRT was studied via dosimetric parameters and radiobiologic mo...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 15  issue Special Issue-12th. Iranian Congress of Medical Physics

pages  342- 342

publication date 2018-12-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023