Comparison of Three-Dimensional Double-Echo Steady-State Sequence with Routine Two-Dimensional Sequence in the Depiction of Knee Cartilage

Authors

  • ali abbaszadeh Department of Epidemiology & Biostatistics School of Health, Mashhad University of Medical Sciences , Mashhad, Iran
  • Behzad Aminzadeh Department of radiology, faculty of medicine, Mashhad University of Medical Sciences, Mashhad, Iran
  • Hormoz abedi Medical Physics Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
Abstract:

Introduction: There are some routine two-dimensional sequences, including short tau inversion recovery (STIR), T2-weighted fast-spin echo (T2W-FSE), and proton-density fast spin-echo for diagnosing osteoarthritis and lesions of the knee cartilage. However, these sequences have some disadvantages, such as long scan time, inadequate spatial resolution, and suboptimal tissue contrast which results in loss of image details, as well as missing the visualization of knee cartilage lesions. Three-dimensional (3D) sequences, such as the double-echo steady-state (DESS) sequence can decrease and overcome these problems to the smallest possible amount. Material and Methods: A total of 15 volunteers with knee pain were examined by a 1.5 Tesla magnetic resonance imaging.The contrast-to-noise ratio (CNR) and thickness values of the knee articular cartilage were measured. The CNR and thickness values were comparedby the Friedman test and the Wilcoxon signed-rank test. Results: The obtained results showed significant differences between sequences in CNR and thickness values. The DESS sequence with a flip angle of 40°showed the best CNR values and 3D fast low-angle shot (FLASH) showed the worst results. In addition, the results showed no significant differences between FLASH, 3D DESS 40° and 90° in terms of cartilage thickness. However, thickness values of these sequences were much higher than that of the PD, T2, and STIR sequences. Conclusion: The 3D DESS sequence with two flip angles of 40°and 90° are the best sequences for visualizing the cartilage and the synovial fluid. Because they provide the best contrast between the cartilage and the synovial fluid, it is recommended to use DESS sequences in the evaluation of cartilage defections.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Comparing Relative Contrast in Three-dimensional Double-echo Steady State With Routine Sequences for a Better Diagnosis of Knee Cartilage Anomalies

Aims This study compared relative contrast values in three-dimensional Double Echo Steady State (DESS) sequences with two flip angles of 40 and 90 degrees and other routine sequences. The obtained data could help to prove the effects of this sequence, compared to the other routine sequences; accordingly, it could be applied for better detection of lesions resulting from cartilage abnormalities....

full text

Optimal Pareto Parametric Analysis of Two Dimensional Steady-State Heat Conduction Problems by MLPG Method

Numerical solutions obtained by the Meshless Local Petrov-Galerkin (MLPG) method are presented for two dimensional steady-state heat conduction problems. The MLPG method is a truly meshless approach, and neither the nodal connectivity nor the background mesh is required for solving the initial-boundary-value problem. The penalty method is adopted to efficiently enforce the essential boundary co...

full text

comparison of catalytic activity of heteropoly compounds in the synthesis of bis(indolyl)alkanes.

heteropoly acids (hpa) and their salts have advantages as catalysts which make them both economically and environmentally attractive, strong br?nsted acidity, exhibiting fast reversible multi-electron redox transformations under rather mild conditions, very high solubility in polar solvents, fairly high thermal stability in the solid states, and efficient oxidizing ability, so that they are imp...

15 صفحه اول

MR cisternography of the cerebellopontine angle: comparison of three-dimensional fast asymmetrical spin-echo and three-dimensional constructive interference in the steady-state sequences.

BACKGROUND AND PURPOSE MR cisternography has been used as the noninvasive screening tool of the cerebellopontine angle. The purpose of this study was to directly compare two currently dominant types of sequences for heavily T2-weighted MR cisternography. METHODS Three-dimensional fast asymmetric spin-echo (3D-FASE) sequences, which are 3D half-Fourier rapid acquisition with relaxation enhance...

full text

Magnetic resonance imaging of knee cartilage using a water selective balanced steady-state free precession sequence.

PURPOSE To compare an optimized water selective balanced steady-state free precession sequence (WS-bSSFP) with conventional magnetic resonance (MR) sequences in imaging cartilage of osteoarthritic knees. MATERIALS AND METHODS Flip angles of sagittal and axial WS-bSSFP sequences were optimized in three volunteers. Subsequently, the knees of 10 patients with generalized osteoarthritis were imag...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 17  issue 2

pages  75- 80

publication date 2020-03-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023