Comparison of dosimetric radiotherapy of whole left- breast cancer using conventional tangential wedge-based techniques (CTT) and three intensity modulation techniques (IMRT)

Authors

  • Ahmad Shanei Medical Physics Department, Isfahan University of Medical Sciences, Isfahan, Iran.
  • Alireza Amoheidari Radiation Oncology Department, Isfahan Milad General Hospital, Isfahan, Iran.
  • Amir Jafari Medical Physics Department, Isfahan University of Medical Sciences, Isfahan, Iran.
  • Iraj Abedi Medical Physics Department, Isfahan University of Medical Sciences, Isfahan, Iran.
Abstract:

Introduction: Whole breast radiotherapy after breast-conserving surgery decrease the risk of local recurrence. this study investigates the dosimetric aspects of intensity modulated radiotherapy (IMRT) compared to conventional tangential wedge-based beams techniques (CTT) of the whole breast in early stages breast cancer patients.   Materials and Methods: Computed tomography images of 35 patients with left sided breast cancer used for whole breast radiotherapy planning were examined. They were planned using four different radiotherapy technique, 1) conventional tangential wedge-based beams techniques (CTT); 2) six beams intensity modulated radiotherapy (IMRT-6F); 3) seven beams intensity modulated radiotherapy (IMRT-7F); and 4) nine beams intensity modulated radiotherapy (IMRT-9F). The PTV dose prescribed was 50 Gy in 25 fractions and V47.5 ≥ 95%. Dose distribution of PTV and OARs, the homogeneity index (HI), and conformity index (CI) were measured and compared to each other.   Results: All of the IMRT plans improved CI (CTT: 0.93 ± 0.019; IMRT-6F: 0.95 ± 0.016; IMRT-7F: 0.96 ± 0.014; IMRT-9F: 0.97 ± 0.010), HI (CTT: 0.21 ± 0.021; IMRT-6F: 0.17 ± 0.013; IMRT-7F: 0.16 ± 0.014; IMRT-9F: 0.15 ± 0.018), mean dose PTV (CTT: 50.88 ± 0.48Gy; IMRT-6F: 51.93 ± 0.37Gy; IMRT-7F: 51.99 ± 0.38Gy; IMRT-9F: 52.14 ± 0.33Gy) and significantly increase volume of ipsilateral lung receiving more than 5Gy and 20Gy (V5Gy - V20Gy) (CTT: 20.05 – 12.69; IMRT-6F:41.69 -16.59; IMRT-7F: 42.13 – 16.74; IMRT- 9F: 48.284 - 17.26) too increase mean dose of Heart (CTT: 6.61 ± 1.47Gy; IMRT-6F: 6.33 ± 1.55Gy; IMRT- 7F: 7.35 ± 2.83Gy; IMRT-9F: 8.35 ± 3.64Gy) compared to CTT. Mean dose of contralateral Breast and contralateral Lung too increase than CTT.   Conclusion: From the dosimetric point of view, the IMRT plans were not significantly advantageous over the 3DCRT plans. IMRT produces better the homogeneity and conformity index of the PTV, but increase low doses to OARs.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Dosimetric comparison of whole breast radiotherapy using field in field and conformal radiotherapy techniques in early stage breast cancer

Background: We aimed to compare field-in-field technique (FIF) with conformal tangential field radiotherapy (CRT) in terms of dosimetric benefits for early stage breast cancer radiotherapy. Materials and Methods: Twenty consecutive left-side breast cancer patients who underwent breast-conserving surgery were included to the study. For each patient, two different treatment plans were cr...

full text

Dosimetric comparison of conventional and field-in-field techniques in early stage breast cancer radiotherapy

Introduction: Breast conserving surgery followed by adjuvant radiotherapy (RT) of the whole breast is accepted as the treatment of choice in early stage breast cancer. Due to breast irregularities, it is difficult to access homogenous dose distribution with conventional techniques. Currently, it is possible to use varied breast irradiation techniques, such as field- in-field (F...

full text

Comparison of forward intensity modulated radiation therapy and two field tangential wedged beam techniques in radiotherapy of breast cancer: dosimetric and radiobiologic study

Introduction: This study aims to compare the dose delivery parameters and radiobiologic model prediction of Tumor Control Probability (TCP) of the FIMRT technique compared with rectangular two tangential wedged fields (2FW) in the treatment of breast cancer. Furthermore, reduction of the heart and lung dose in the FIMRT was studied via dosimetric parameters and radiobiologic mo...

full text

dosimetric comparison of whole breast radiotherapy using field in field and conformal radiotherapy techniques in early stage breast cancer

background: we aimed to compare field-in-field technique (fif) with conformal tangential field radiotherapy (crt) in terms of dosimetric benefits for early stage breast cancer radiotherapy. materials and methods: twenty consecutive left-side breast cancer patients who underwent breast-conserving surgery were included to the study. for each patient, two different treatment plans were created for...

full text

Dosimetric comparison of whole breast radiotherapy using field in field and conformal radiotherapy techniques in early stage breast cancer

*Corresponding author: Dr. Guler Yavas, Selcuk University, Faculty of Medicine Department of Radiation Oncology, Konya, Turkey. Fax: +90 332 241 60 65 E-mail: [email protected] Background: We aimed to compare field-in-field technique (FIF) with conformal tangential field radiotherapy (CRT) in terms of dosimetric benefits for early stage breast cancer radiotherapy. Materials and Methods...

full text

A comparative dosimetric study for treating left-sided breast cancer for small breast size using five different radiotherapy techniques: conventional tangential field, filed-in-filed, Tangential-IMRT, Multi-beam IMRT and VMAT

BACKGROUND AND PURPOSES To compare the dosimetry for the left-sided breast cancer treatment using five different radiotherapy techniques. MATERIALS AND METHODS Twenty patients with left sided breast cancer were treated with conservative surgery followed by radiotherapy. They were planned using five different radiotherapy techniques, including: 1) conventional tangential wedge-based fields (TW...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 15  issue Special Issue-12th. Iranian Congress of Medical Physics

pages  247- 247

publication date 2018-12-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com