Comparison of cone beam computed tomography and digital radiography in detection of pulpal exposure in external cervical root resorption

Authors

  • Ghaznavy, Amineh Post-Graduate Student, Department of Periodontics, School of Dentistry, Esfahan University of Medical Sciences, Esfahan, Iran
  • Moshari, Amir Abbas Assistant Professor, Department of Endodontics, School of Dentistry, Islamic Azad University, Tehran, Iran
  • Talaeipour, Ahmad Reza Professor, Department of Oral and Maxillofacial Radiology, School of Dentistry, Islamic Azad University, Tehran, Iran
  • Vatanpour, Mehdi Associated Professor, Department of Endodontics, School of Dentistry, Islamic Azad University, Tehran, Iran
Abstract:

Background and Aims: Pulpal exposures originated from the external cervical root resorptions have major effects on the treatment and prognosis. Therefore, the aim of this study was performed to compare the two different imaging systems-digital radiography with PSP (Photostimulable Phosphor) sensor in three horizontal different views and CBCT (cone beam computed tomography) images to assess the pulpal exposure in simulated cavity of external cervical root resorptions that was performed in 1398 in the School of Dentistry of Azad University. Materials and Methods: 40 intact maxilla anterior teeth with straight roots were included. Teeth were randomly divided to two groups (20 teeth with and 20 without pulpal exposures). Each sample was assessed using PSP digital radiography (in 3 horizontal angles) and CBCT image system, to detect the presence of pulpal exposures. False negative and false positive results in 2 imaging procedures were judged with ratio test. Results: The results showed in CBCT (P.P.V=85.7%) and (N.P.V=89.5%), and in digital intraoral radiography (P.P.V=80%) and (N.P.V=80%) in proximal defects. Ratio test showed that there were no significant differences in the proximal defects (P<0.4). Conclusion: The results showed that there were no significant differences in detection of exposure in the proximal surfaces between two imaging systems.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Accuracy of digital periapical radiography and cone-beam computed tomography in detecting external root resorption

PURPOSE The purpose of this study was to evaluate and compare the efficacy of cone-beam computed tomography (CBCT) and digital intraoral radiography in diagnosing simulated small external root resorption cavities. MATERIALS AND METHODS Cavities were drilled in 159 roots using a small spherical bur at different root levels and on all surfaces. The teeth were imaged both with intraoral digital ...

full text

effect of field of view on detection of external root resorption in cone-beam computed tomography

introduction: conventional methods for diagnosis of external root resorption (err) are based on clinical findings and x-ray observations which are not appropriate for early diagnosis. the present study assessed the effect of different sizes and field of views (fovs) in the diagnosis of simulated external root resorption by cone-beam computed tomography (cbct). methods and materials: in this dia...

full text

Comparison of Diagnostic Accuracy of Cone Beam Computed Tomography and Digital Radiography for Detection of Vertical Root Fractures with and without Gutta Percha

  Objective: Diagnosis of vertical root fractures (VRFs) is critical in endodontics which most of the times occurs in endodontically treated teeth with root canal fillings such as gutta percha. Despite Cone Beam Computed Tomography (CBCT) has significantly enhanced image quality compared to digital radiography (DR) which aid the diagnosis, artifacts has remained as a problem in VRF detection . ...

full text

effect of voxel size on detection of external root resorption defects using cone beam computed tomography

conclusion considering the similar diagnostic efficacy of all voxel sizes, 300 µm voxel size can be used with adequate efficacy for detection of external root resorption defects with minimal patient radiation dose and the shortest scanning time. background selecting a voxel size that yields minimal radiation dose with no significant compromise of the diagnostic accuracy of cone beam computed to...

full text

diagnostic accuracy of cone-beam computed tomography and periapical radiography in internal root resorption

introduction: the aim of this study was to compare the diagnostic value of cone-beam computed tomography (cbct) and periapical (pa) radiography in detecting internal root resorption. methods and materials: eighty single rooted human teeth with visible pulps in pa radiography were split mesiodistally along the coronal plane. internal resorption like lesions were created in three areas (cervical,...

full text

The Effect of Intra-Canal Posts on Diagnostic Accuracy of Cone Beam Computed Tomography and Digital Radiography in Detection of Vertical Root Fractures

Objective: Diagnosis of vertical root fractures (VRFs) is critical in endodontics. Cone Beam Computed Tomography (CBCT)  has significantly enhanced image quality compared to digital radiography (DR) and greatly aids the diagnosis of VRFs but, metal artifacts has remained as a problem in VRF detection.  This study evaluated the effect of intra canal posts on the diagnostic accuracy of CBCT and D...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 33  issue 4

pages  220- 226

publication date 2021-01

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

No Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023