Comparison of 6 PET scanners, a simulation study [Persian]

Authors

  • Ahmad Bitarafan Rajabi Department of Medical Physics, Tarbiat Modarres University, Tehran, Iran
  • Ebrahim Hajizadeh Department of Biostatistics, Tarbiat Modarres University, Tehran, Iran
  • Habib Zaidi Division of Nuclear Medicine, Geneva University Hospital, Geneva, Switzerland
  • Hamid Reza Ghiasi Department of Medical Physics, Tarbiat Modarres University, Tehran, Iran
  • Hossein Rajabi Department of Medical Physics, Tarbiat Modarres University, Tehran, Iran
  • Kourosh Ebrahimnezhad Gorji Department of Medical Physics, Tarbiat Modarres University, Tehran, Iran
Abstract:

Introduction: Due to the large number of PET systems available in the market, it is not very easy to decide about the scanner of choice. Conducting a research in order to compare all different PET scanners is very time consuming and expensive and practically impossible. However, such comparison may be conducted using PET simulators. In this study, the performance of 6 different PET scanners in cardiology is evaluated using a dedicated PET simulator. In this study only the design of the system were evaluated. Methods: Activity and attenuation phantoms were produced using 4D-NCAT phantom. ECAT EXACT HR+, ECAT 953B, ECAT 966, ECAT ART, GE Advance and 16HI-REZ scanners were simulated using Eidolon PET simulator and the output sinograms were reconstructed using STIR software. The reconstructed images were processed using Interview software installed on the Mediso cardiac imaging system. Counts of pixels determined by ROI were used to drawn curves and then the correlations of these curves calculated using SPSS. Results: True coincidences 2D was 4651791±5900 for ECAT 966, 4651965±5660 for ECAT ART, 4742731±5328 for ECAT EXACT HR+, 6018435±5167 for ECAT 953B, 6566769±4734 for GE Advance and 6846339±51850 for 16HI-REZ. Resulted correlations calculated for these scanners were 0.806, 0.795, 0.718, 0.858, 0.726 and 0.896 respectively. Conclusion: There was a considerable different in scatter fractions of different scanners. Curves drawn using count of pixels determined by ROI and correlations of these curves showed differences in performances of scanners in cardiology. The results showed that the 16HI-REZ scanner is the best scanner of the six scanners for simulating of cardiac PET images.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

comparison of 6 pet scanners, a simulation study [persian]

introduction: due to the large number of pet systems available in the market, it is not very easy to decide about the scanner of choice. conducting a research in order to compare all different pet scanners is very time consuming and expensive and practically impossible. however, such comparison may be conducted using pet simulators. in this study, the performance of 6 different pet scanners in ...

full text

a study of translation of english litrary terms into persian

چکیده هدف از پژوهش حاضر بررسی ترجمه ی واژه های تخصصی حوزه ی ادبیات به منظور کاوش در زمینه ی ترجمه پذیری آنها و نیز راهکار های به کار رفته توسط سه مترجم فارسی زبان :سیامک بابایی(1386)، سیما داد(1378)،و سعید سبزیان(1384) است. هدف دیگر این مطالعه تحقیق در مورد روش های واژه سازی به کار رفته در ارائه معادل های فارسی واژه های ادبی می باشد. در راستای این اهداف،چارچوب نظری این پژوهش راهکارهای ترجمه ار...

15 صفحه اول

Performance comparison of four commercial GE discovery PET/CT scanners: A monte carlo study using GATE

  Combined PET/CT scanners now play a major role in medicine for in vivo imaging in oncology, cardiology, neurology, and psychiatry. As the performance of a scanner depends not only on the scintillating material but also on the scanner design, with regards to the advent of newer scanners, there is a need to optimize acquisition protocols as well as to compare scanner ...

full text

Attenuation correction for hybrid MR/PET scanners: a comparison study.

Forschungszentrum Jülich GmbH, Jülich, Germany Attenuation correction of PET data acquired in hybrid MR/PET scanners is still a challenge. Different methods have been adopted by several groups to obtain reliable attenuation maps (mu-maps). In this study we compare three methods: MGH, UCL, Neural-Network. The MGH method is based on an MR/CT template obtained with the SPM8 software. The UCL metho...

full text

Comparison of TOF-PET and Bremsstrahlung SPECT images of Yttrium-90: A Monte Carlo Simulation Study

Objective(s): Yttrium-90 (90Y) is a beta particle nuclide used in targeted radionuclide therapy which is available to both single-photon emission computed tomography (SPECT) and time-of-flight (TOF) positron emission tomography (PET) imaging. The purpose of this study was to assess the image quality of PET and Bremsstrahlung SPECT by simulating PET and SPECT images of 90Y using Monte Carlo simu...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 15  issue 1

pages  24- 35

publication date 2007-01-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023