Comparison and evaluation of dosimetric and radiobiological parameters in two different treatment plans in stomach cancer by use of 3D CRT

Authors

  • Farid Nezhad Dadgar Assistance Prof. of Radiation Oncology, Sina Radiotherapy Oncology Department, Bu Ali Hospital, Islamic Azad University, Medical College, Tehran, Iran.
  • Hassan Ali Nedaie Assistant Prof. of Medical Physics, Radiotherapy Oncology Department, Tehran University of Medical Sciences, Tehran, Iran.
  • Kaveh Shirani Tak Abi Medical Physicist of Sina Radiotherapy Oncology Department, Bu Ali Hospital, Tehran, Iran.
  • Malihe Rezaie Yazdi Medical physicist of Iran Mehr Radiotherapy Oncology Department, Iran Mehr Hospital, Birjand, Iran.
  • Maryam Rezaie Yazdi Medical physicist of Iran Mehr Radiotherapy Oncology Department, Iran Mehr Hospital, Birjand, Iran.
  • Narges Kheirollahi Medical physicist of Imam Reza Radiotherapy Oncology Department, Imam Reza Hospital, Mashhad, Iran.
  • Payam Izadpanahi Radiation Oncologist of Iran Mehr Radiotherapy Oncology Department, Iran Mehr Hospital, Birjand, Iran.
  • Reza KhodaBakhshi Radiation Oncologist, Consultant and Executive Director of Sina Radiotherapy Oncology Department, Bu Ali Hospital, Tehran, Iran.
Abstract:

Introduction: In 3DCRT the number of therapeutic fields has dramatic impact on treatment results especially in stomach cancer. Traditionally, for radiotherapy of stomach cancer the therapeutic procedure was using two fields (AP- PA or AP Lateral with wedge) to achieve smooth and homogeneous dose distribution in tumor. But nowadays, adding lateral or oblique fields to aforementioned techniques lead to reducing dose to organ at risks (OARs) like spinal cord, liver, both kidneys and better dose distribution in tumor. Moreover, there are a several ways to evaluate traditional and novel techniques in 3DCRT for stomach cancer. for example, Tumor Control Probability (TCP) and Normal Tissue Complication Probability (NTCP) from radiobiological point of view and Homogeneity Index (HI), Conformity Index (CI) as a dosimetric parameters. Thus, the aim of this study is to assess and compare two different plans in stomach cancer by using homogeneity Index, conformity index, TCP and NTCP as guidance criteria in 3DCRT.   Materials and Methods: In this study, 10 patients with stomach cancer were chosen. Two different of treatment plans; three fields (AP, PA, and lateral) and four fields (AP, PA and two laterals) were prepared. A photon beam of 6MV quality was used for both treatment plans in PCRT 3D as treatment planning system. Prescribed dose was 5o.4 Gy for tumor. Therapeutic aim for all treatment plans was to deliver at least 95% of prescribed dose to 97% of target volume while sparing organ at risks. The normalization of each plan followed the recommendation of ICRU report 50. The tumor volume selected for calculating the HI, CI and TCP and OARs for NTCP.   Results:Average ratio of the calculated parameters in treatment plans of four fields over three fields with standard deviation (Mean /SD) was 1.05±0.13 for CI and 0.99±0.01 for HI. In addition, Treatment ratio for four fields over three fields was 1±0.02. Damage ratio to spinal cord and liver was 0.57±0.18 and 2.09±0.93 respectively for treatment plans with four fields in comparison of treatment plans by using of three therapeutic fields.   Conclusion: Results show that, HI and CI parameters are approximately equal in two treatment plans. Therefore, both of the treatment plans are acceptable for clinical use. Assessment TCP and NTCP radiobiology parameter determined that, tumor control probability for both treatment plans are same but, damage probability of liver in three field treatment plan is less than over four fields while damage probability of spinal cord in four field treatment plan is lower than three fields treatment planning.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

assessment of deep word knowledge in elementary and advanced iranian efl learners: a comparison of selective and productive wat tasks

testing plays a vital role in any language teaching program. it allows teachers and stakeholders, including program administrators, parents, admissions officers and prospective employers to be assured that the learners are progressing according to an accepted standard (douglas, 2010). the problems currently facing language testers have both practical and theoretical implications but the first i...

Dosimetric comparison of treatment of left breast cancer using two different dose schedules Dosimetric comparison of treatment of left breast cancer using two different dose schedules

Background: To date, different kinds of treatment methods have been proposed for radiotherapy of cancer patients. Choosing the kind of treatment method affects the quality of the patient's treatment. This study aims to investigate the effect of the number of radiation treatment sessions on the dose received by the patient and the distribution of tumor dose and dose received by organs at risk in...

full text

investigation of single-user and multi-user detection methods in mc-cdma systems and comparison of their performances

در این پایان نامه به بررسی روش های آشکارسازی در سیستم های mc-cdma می پردازیم. با توجه به ماهیت آشکارسازی در این سیستم ها، تکنیک های آشکارسازی را می توان به دو دسته ی اصلی تقسیم نمود: آشکارسازی سیگنال ارسالی یک کاربر مطلوب بدون در نظر گرفتن اطلاعاتی در مورد سایر کاربران تداخل کننده که از آن ها به عنوان آشکارساز های تک کاربره یاد می شود و همچنین آشکارسازی سیگنال ارسالی همه ی کاربران فعال موجود در...

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 15  issue Special Issue-12th. Iranian Congress of Medical Physics

pages  34- 34

publication date 2018-12-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023