Chromium(III) ion selective electrode based on 2H-1,4-benzothioazine-2,3(4H)dione dioxime as a neutral carrier
Authors
Abstract:
A poly(vinyl chloride) membrane based on a new a-dioxime derivative as membrane carrier was prepared andinvestigated as a Cr(III) selective electrode. The electrode exhibits a good potentiometric response for Cr(III)over a wide concentration range 1.0 x 10-6 to 1.0 x 10-1 M with a slope 19.5+0.5 mV/decade and low detectionlimit of 8.9 x 10-7 M. It has a fast response time < 15 s. The best performance was observed with the membrancehaving the PVC-ligand-acetophenone-oleic acid composition 6:1:13:1. The proposed electrode works well in awide p1-1 range 1.5-5.5. The proposed sensor was successfuly used for the determination of Cr(III) ions insamples and real samples and as indicator electrode in potentiometric titration of Cr(III) ion. The application ofthis electrode for Cr(III) determination in real samples is described. The results obtained with this procedure arein close agreement with those obtained using AA spectrophotometry.
similar resources
chromium(iii) ion selective electrode based on 2h-1,4-benzothioazine-2,3(4h)dione dioxime as a neutral carrier
a poly(vinyl chloride) membrane based on a new a-dioxime derivative as membrane carrier was prepared andinvestigated as a cr(iii) selective electrode. the electrode exhibits a good potentiometric response for cr(iii)over a wide concentration range 1.0 x 10-6 to 1.0 x 10-1 m with a slope 19.5+0.5 mv/decade and low detectionlimit of 8.9 x 10-7 m. it has a fast response time < 15 s. the best perfo...
full textA mercury(II) ion-selective electrode based on N,N-dimethylformamide-salicylacylhydrazone as a neutral carrier.
A new PVC membrane mercury(II) ion electrode based on N,N-dimethylformamide-salicylacylhydrazone (DMFAS) as an ionophore is described, which shows excellent potentiometric response characteristics and displays a linear log[Hg(2+)] versus EMF response over a wide concentration range between 6.2 x 10(-7) and 8.0 x 10(-2) M with a Nerstian slope of 29.6 mV per decade and a detection limit of 5.0 x...
full textDetermination of Mn2+ in Pharmaceutical Supplements by a Novel Coated Graphite Electrode Based on Zolpidem as a Neutral Ion Carrier
Manganese plays a key role in the health of human beings therefore, its determination is very important in medical fields. In this regards, a novel coated graphite electrode was constructed for determination of manganese (II) by using zolpidem as an ionophore, for the first time. The best performance was obtained of the membrane composition of PVC (32%), Potassium tetrakis (4-chlorophenyl) bora...
full textSelective Membrane Electrode for Bromide Ion Based on Aza Pyrilium Ion Derivative as a new Ionophore.
A highly selective electrode for Bromide ion based on aza pyrilium derivative as an excellentionophore is described.The sensor exhibits a good linear response with a slope of ( 60±1 ) mV per decadeover the concentration range of ( 1×10-3 – 9×10-6 M ) , and a detection limit of ( 3×10-6 M ) of Bromideions .The electrode response is independent of pH in the range of(4.0 –9.5).Selectivity coeffici...
full textLanthanum(III) Ion Selective Electrode Based on a New Ionophore
A PVC membrane electrode based on 1-[({[(butylsulfunyl)carbothioyl]disulfanyl} carbothioyl)sulfanyl]butane as a suitable ion carrier for determination of lanthanum(III) ion was prepared. This electrode revealedsuch a good selectivity toward La3+ ion over a wide variety of other metal ions. Some experimental parametersuch as membrane composition, nature, and amount of plasticizer, the amount of ...
full textNovel ZrO2 ion-selective electrode based on 4,7,13,16,21,24-hexa oxa- 1,10- diazabicyc1o[8,8,8]-hexa cosane as neutral carrier in PVC matrix
In this work, a novel Zr02+ PVC-based membrane sensor based on 4,7,13,16,21,24-hexa oxa-1,10- diazabicyclo[8,8,8]- hexa cosane (HODBHC) as a new ionophore is presented. The sensor displays a linear dynamic rangebetween 1.0x 10-1 and 1.0x10 6 M, with a near Nernstian slope of 29.9 ± 0.4 mV per decade in an acidic solution(pH=1). The limit of detection is 8.0 x 1 0 7 M. The electrodes possess adv...
full textMy Resources
Journal title
volume 8 issue 1
pages 17- 22
publication date 2011-05-01
By following a journal you will be notified via email when a new issue of this journal is published.
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023