Chemiluminescence Determination of Atropine using Luminol-Hemin-H2O2 System
Authors
Abstract:
A sensitive and fast chemiluminescence (CL) method has been described for the direct determination of atropine. The method is based on the quenching effect of atropine on the CL signals of the luminol– H2O2 reaction catalyzed by hemin in an alkaline medium. Hemin could strongly enhance the chemiluminescence of the luminol–H2O2 system. The luminophor of the luminol–H2O2–hemin CL system was identified as the excited state 3-aminophthalate anion. The CL from luminol–H2O2–hemin system is strongly inhibited by the presence of atropine. Under the optimum conditions, the CL intensity is proportional to the concentration of the atropine in solution over the range 0.1-29 µg/ml. Detection limit and relative standard were 0/045 µg/ml and less than 4%, respectively. The proposed method has been utilized for the determination of atropine in injection and urine samples (The urine samples were collected from different healthy volunteers) withsatisfactory results. Recovery tests were also carried out by adding a known amount of atropine in samples.
similar resources
chemiluminescence determination of atropine using luminol-hemin-h2o2 system
a sensitive and fast chemiluminescence (cl) method has been described for the direct determination of atropine. the method is based on the quenching effect of atropine on the cl signals of the luminol– h2o2 reaction catalyzed by hemin in an alkaline medium. hemin could strongly enhance the chemiluminescence of the luminol–h2o2 system. the luminophor of the luminol–h2o2–hemin cl system was ident...
full textChemiluminescence Determination of Some Fluoroquinolones Using NBS-Luminol System
A new, simple, rapid and sensitive batch chemiluminescence (CL) method for determination of six fluoroquinolones (ciprofloxacin, gatifloxacin, levofloxacin, lomefloxacin HCl, ofloxacin and sparfloxacin) is proposd. The method is based on the CL generated during the oxidation of luminol by N-bromosuccinimide (NBS) in alkaline medium. The determination of the studied drugs is based on their inhib...
full textChemiluminescence determination of melamine with Luminol-K3Fe(CN)6 system
A sensitive chemiluminescence (CL) method was developed for determining melamine in urine and plasma samples based on the fact that melamine can remarkably enhance the chemiluminescence of Luminol-K3 Fe(CN)6 system in alkaline medium. The determination conditions were optimized. Under optimum conditions, the chemiluminescence intensity had a good linear relationship with melamine in the range o...
full textChemiluminescence Determination of Mezlocillin by the Luminol-Potassium Periodate System
Um método novo, simples e sensível foi proposto para a determinação de mezlocilina. Baseia-se na amplificação da emissão de quimiluminescência (CL) gerada a partir da oxidação do luminol em meio alcalino pelo periodato de potássio. A otimização das variáveis experimentais e instrumentais que afetam o efeito da amplificação de CL foi realizada usando-se sistema de injeção em fluxo. Em condições ...
full textFlow-injection electrogenerated chemiluminescence determination of isoniazid using luminol.
Based on a new electrogenerated chemiluminescence (ECL) analytical idea, this paper explains a sensitive and selective flow-injection ECL method using luminol for the determination of isoniazid, based on the sensitizing effect of isoniazid for the weak ECL emission of electrochemically oxidized luminol. Under the optimum experimental conditions, the relative ECL intensity was linear with isonia...
full textCetyltrimethylammonium bromide-enhanced chemiluminescence determination of uric acid using a luminol-hexacyanoferrate(III)-hexacyanoferrate(II) system.
A chemiluminescence (CL) method using flow injection (FI) was developed for the determination of uric acid based on the enhancement chemiluminescence intensity of luminol-hexacyanoferrate(III)-hexacyanoferrate(II) in the presence of cetyltrimethylammonium bromide and the uric acid species. The linear range was 7.0 x 10(-10) - 9.0 x 10(-7) M with a detection limit (3sigma) of 2.58 x 10(-10) M, w...
full textMy Resources
Journal title
volume 3 issue 1
pages 7- 13
publication date 2014-10-01
By following a journal you will be notified via email when a new issue of this journal is published.
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023