Characterization of Am-Be neutron source based PGNAA setup using aqueous solutions of Chlorine and Boron

Authors

  • D. Meena Department of Physics, University of Rajasthan, 302004 Jaipur, India
  • H.S. Palsania Department of Physics, University of Rajasthan, 302004 Jaipur, India
  • N. Chejara Department of Physics, University of Rajasthan, 302004 Jaipur, India
  • N. Jakhar Department of Physics, University of Rajasthan, 302004 Jaipur, India
  • P. Meena Department of Zoology, University of Rajasthan, 302004 Jaipur, India
  • S.K. Gupta Department of Physics, University of Rajasthan, 302004 Jaipur, India
Abstract:

Background: A 5 Ci 241Am-Be radio isotopic neutron source-based prompt gamma neutron activation analysis (PGNAA) setup was designed for estimation of minimum detectable concentration (MDC) of elements in aqueous solutions. Materials and Methods: Performance variables related to PGNAA setup (source to sample distance, sample to detector distance and volume of water) were optimized experimentally. Characterization of the setup was done by chlorine and boron elements using sodium chloride (NaCl) and boric acid (H3BO3) compounds respectively. Results: PGNAA setup was calibrated for different concentrations of Cl and B in aqueous solution. The chlorine concentration was varied over 1.2 g/L, 2.4 g/L, 3.6 g/L, 4.8 g/L, 6.0 g/L and 7.2 g/L in water samples while boron concentration was varied over 0.1 g/L, 0.2 g/L, 0.3 g/L, 0.4 g/L and 0.5 g/L. The MDC of chlorine and boron were calculated for various characteristic prompt gamma energies. Estimated MDC of chlorine and boron are 175 ± 53 ppm at prompt gamma energy 6110 keV and 3 ± 0.95 ppm at prompt gamma energy 478 keV respectively. Conclusion: In the present work, PGNAA setup was developed and characterized for the in-situ analysis of aqueous solutions using a 5 Ci Am-Be neutron source. The chlorine concentration was varied from 1.2 to 7.2 g/L and boron concentrations were varied from 0.1 to 0.5 g/L. The setup shows linear response for both chlorine and boron for wide energy range. The obtained results were also compared with other previous published work. It shows good agreement with present results.   

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Utilization of Am-Be Neutron Source in PGNAA Setup Used in Cement Raw Material Analysis

Hundreds of cement factories use online bulk material analyzers to improve their quality control for both raw material and kiln feed, and reduce their variability. The most used technology for online analysis is Prompt Gamma Neutron Activation Analysis (PGNAA), with Cf as the neutron source. Cost and short half-life of the Cf neutron sources are the main problems in cement industry. Therefore, ...

full text

Designing an Am-Be miniature neutron source

Background: Miniature neutron sources with high neutron flux have abundant applications in medicine, industry and researches. The most important general characteristic of miniature neutron sources is their diameter which is 3mm in average. In this research, we have surveyed and designed an Am-Be miniature neutron source fabrication. Materials and Methods: This investigation resulted in creation...

full text

designing an am-be miniature neutron source

background: miniature neutron sources with high neutron flux have abundant applications in medicine, industry and researches. the most important general characteristic of miniature neutron sources is their diameter which is 3mm in average. in this research, we have surveyed and designed an am-be miniature neutron source fabrication. materials and methods: this investigation resulted in creation...

full text

Use of 7Li(p,n) reaction as a neutron source in a PGNAA setup.

The performance of a 7Li(p,n) reaction-based Prompt Gamma Ray Neutron Activation Analysis (PGNAA) setup has been determined for analysis of Portland cement samples using Monte Carlo study. The calculations were carried out for a 7Li(p,n) reaction-based PGNAA setup with an external moderator similar to the one used in a previous 2.8 MeV neutrons-based PGNAA setup. The optimum values of geometry ...

full text

synthesis and characterization of some macrocyclic schiff bases

ماکروسیکلهای شیف باز از اهمیت زیادی در شیمی آلی و دارویی برخوردار می باشند. این ماکروسیکلها با دارابودن گروه های مناسب در مکانهای مناسب می توانند فلزاتی مثل مس، نیکل و ... را در حفره های خود به دام انداخته، کمپلکسهای پایدار تولید نمایند. در این پایان نامه ابتدا یک دی آلدئید آروماتیک از گلیسیرین تهیه می شود و در مرحله بعدی واکنش با دی آمینهای آروماتیک و یا آلیفاتیک در رقتهای بسیار زیاد منجر به ت...

15 صفحه اول

Design and Simulation of Photoneutron Source by MCNPX Monte Carlo Code for Boron Neutron Capture Therapy

Introduction Electron linear accelerator (LINAC) can be used for neutron production in Boron Neutron Capture Therapy (BNCT). BNCT is an external radiotherapeutic method for the treatment of some cancers. In this study, Varian 2300 C/D LINAC was simulated as an electron accelerator-based photoneutron source to provide a suitable neutron flux for BNCT. Materials and Methods Photoneutron sources w...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 17  issue 2

pages  301- 308

publication date 2019-04

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023