Cardiac and Hepatic T2*-Weighted Magnetic Resonance Imaging
Authors
Abstract:
Abstract Background Iron overload is the main transfusion related side effects in patients with transfusion dependent hemoglobinopathies. Severe iron deposition in tissues leads to organ dysfunction. Many organs can be affected such as heart, liver, and endocrine organs. Cardiac failure and liver fibrosis are the consequent of Iron overload in transfusion dependent hemoglobinopathy. Magnetic Resonance Imaging (MRI) is a safe, noninvasive, and accurate method for the assessment of iron deposition in different tissues. This study assessed iron levels in liver and heart of the patients with transfusion dependent hemoglobinopathies. Materials and Methods The studied population consisted of 12 patients (7 male and 5 female) with transfusion dependent hemoglobinopathies, aged between 10-18 years old. Then, Cardiac and liver T2*-weighted magnetic resonance imaging (MRI) were obtained. Results In current study, 1patient (8.33%) had severe, 2 patients (16.66%) had moderate and 2(16.66%) had mild cardiac iron deposition. Out of 12 patients, 1 had severe iron deposition in liver (8.33%), 5(41.66%) and 4(33.33%) had moderate and mild hepatic iron deposition, respectively. Differences between Hepatic and cardiac iron levels were not significant between males and females (p>0.05). Conclusion Since cardiac and liver iron levels were higher than normal in most of the study group, checking ferritin level and liver function test and also echocardiography in shorter intervals (each 3 months) in involved group is suggested instead of checking routinely in 6 month intervals in patients with transfusion dependent hemoglobinopathies.
similar resources
cardiac and hepatic t2*-weighted magnetic resonance imaging
abstract background iron overload is the main transfusion related side effects in patients with transfusion dependent hemoglobinopathies. severe iron deposition in tissues leads to organ dysfunction. many organs can be affected such as heart, liver, and endocrine organs. cardiac failure and liver fibrosis are the consequent of iron overload in transfusion dependent hemoglobinopathy. magnetic re...
full textCardiac and Hepatic T2*-Weighted Magnetic Resonance Imaging in Transfusion Dependent Hemoglobinopathy in North West of Iran
BACKGROUND Iron overload is the main transfusion related side effects in patients with transfusion dependent hemoglobinopathies. Severe iron deposition in tissues leads to organ dysfunction. Many organs can be affected such as heart, liver, and endocrine organs. Cardiac failure and liver fibrosis are the consequent of Iron overload in transfusion dependent hemoglobinopathy. Magnetic Resonance I...
full textT2-weighted cardiovascular magnetic resonance in acute cardiac disease
Cardiovascular magnetic resonance (CMR) using T2-weighted sequences can visualize myocardial edema. When compared to previous protocols, newer pulse sequences with substantially improved image quality have increased its clinical utility. The assessment of myocardial edema provides useful incremental diagnostic and prognostic information in a variety of clinical settings associated with acute my...
full textassessment of cerebral venous sinus thrombosis using t2*-weighted gradient echo magnetic resonance imaging sequences
background: the purpose of this study is to demonstrate the advantages of gradient echo (gre) sequences in the detection and characterization of cerebral venous sinus thrombosis compared to conventional magnetic resonance sequences. methods: a total of 17 patients with cerebral venous thrombosis (cvt) were evaluated using different magnetic resonance imaging (mri) sequences. the mri sequences i...
full textDNA Damages on Blood Cells After Cardiac Magnetic Resonance Imaging
Introduction: Along with the increased use of cardiac imaging at clinics there is increased attention to the potential risks related to the methods used like magnetic resonance (MR) and it cannot be ruled out that MR can alter DNA structure. The aim of this review is to assess the impact of routine cardiac magnetic resonance (CMR) scanning on DNA damages in human T lymphocytes....
full textMy Resources
Journal title
volume 5 issue 4
pages 206- 210
publication date 2015-12
By following a journal you will be notified via email when a new issue of this journal is published.
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023