Calculation of Positron Distribution in the Presence of a Uniform Magnetic Field for the Improvement of Positron Emission Tomography (PET) Imaging Using GEANT4 Toolkit

Authors

  • Ali Asghar Mowlavi Physics Department, Hakim Sabzevari University, Sabzevar, Iran. International Centre for Theoretical Physics (ICTP), Associate and Federation Schemes, Medical Physics Field, Trieste, Italy.
  • Mohsen Mashayekhi Physics Department, Hakim Sabzevari University, Sabzevar, Iran.
Abstract:

Introduction Range and diffusion of positron-emitting radiopharmaceuticals are important parameters for image resolution in positron emission tomography (PET). In this study, GEANT4 toolkit was applied to study positron diffusion in soft tissues with and without a magnetic field for six commonly used isotopes in PET imaging including 11C, 13N, 15O, 18F, 68Ga, and 82Rb. Materials and Methods GEANT4 toolkit was used to simulate the transport and interactions of positrons. Calculations were performed for the soft tissue phantom (8 mm ×8 mm × 8 mm). Positrons were emitted isotropically from the center of the phantom. By the application of a magnetic field perpendicular to the path of positrons, lateral scattering of positrons could be prevented due to Lorentz force. When the positron energy was below the cut-off threshold (0.001 MeV), the simulation was terminated. Results The findings showed that the presence of a magnetic field increased the rate of positron annihilation. At magnetic field strengths of 3, 7, and 10 Tesla, 18F with the lowest decay energy showed improvements in the ratio of full width at half maximum (FWHM) resolution to the peak of curve by 3.64%, 3.89%, and 5.96%, respectively. In addition, at magnetic field strengths of 3, 7 and 10 Tesla, 82Rb with the highest decay energy showed improvements in resolution by 33%, 85%, and 99%, respectively. Conclusion Application of a magnetic field perpendicular to the positron diffusion plane prevented the scattering of positrons, and consequently, improved the intrinsic spatial resolution of PET imaging, caused by positron range effects.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

calculation of positron distribution in the presence of a uniform magnetic field for the improvement of positron emission tomography (pet) imaging using geant4 toolkit

introduction range and diffusion of positron-emitting radiopharmaceuticals are important parameters for image resolution in positron emission tomography (pet). in this study, geant4 toolkit was applied to study positron diffusion in soft tissues with and without a magnetic field for six commonly used isotopes in pet imaging including 11c, 13n, 15o, 18f, 68ga, and 82rb. materials and methods gea...

full text

The effect of fasting on Positron Emission Tomography (PET) imaging

As a nuclear approach, Positron Emission Tomography (PET) is a functional imaging technique which is based on the detection of gamma ray pairs emitted by a positron-emitting radionuclide. There are certain limitations to this technique such as normal tissue uptake. Therefore, it has been recommended that patients prepare before scanning. Fasting for a short while before PET imaging is an exampl...

full text

the effect of fasting on positron emission tomography (pet) imaging

as a nuclear approach, positron emission tomography (pet) is a functional imaging technique which is based on the detection of gamma ray pairs emitted by a positron-emitting radionuclide. there are certain limitations to this technique such as normal tissue uptake. therefore, it has been recommended that patients prepare before scanning. fasting for a short while before pet imaging is an exampl...

full text

the effect of using critical discourse analytical tools on the improvement of the learners level of critical thinking in reading comprehension

?it is of utmost priority for an experienced teacher to train the mind of the students, and enable them to think critically and correctly. the most important question here is that how to develop such a crucial ability? this study examines a new way to the development of critical thinking utilizing critical discourse analytical tools. to attain this goal, two classes of senior english la...

the use of appropriate madm model for ranking the vendors of mci equipments using fuzzy approach

abstract nowadays, the science of decision making has been paid to more attention due to the complexity of the problems of suppliers selection. as known, one of the efficient tools in economic and human resources development is the extension of communication networks in developing countries. so, the proper selection of suppliers of tc equipments is of concern very much. in this study, a ...

15 صفحه اول

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 12  issue 1

pages  7- 13

publication date 2015-03-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023