Introduction: Renal dynamic study is a well-established and popular test in routine practice of nuclear medicine. The test is non-invasive, rapid and unique in evaluation of the kidney function. In despite of its clinical values, the parameters derived from renogram are physiologically meaningless. That is due to the fact that renogram is not the true kidney function. From mathematical points of view, renogram is the convolution of kidney function and kidney input function. The real kidney function, which is usually called Impulse Retention Function, could be derived using deconvolution technique. The main parameters that can be derived from IRF are transit times. Methods and Materials: The data collected from 30 normal healthy individual volunteers were used for calculation of transit times. Due to sensitivity of the deconvolution technique to the error and to minimize the error in the raw data, an investigation was launched to determine the most suitable method of noise reduction, background subtraction and numerical method of deconvolution. Based on our finding, a software package was developed on the system and evaluated using software phantom. Results: Our results shows that among different transit time parameters for different parts of the kidney, mean transit time of the parenchymal is statistically the most valuable parameter. Assuming a Gaussian distribution for the parameter and accepting a 95% confidence interval, the normal rage of mean parenchymal transit time was calculated to be “205±70 Sec”. Using the same logic, the abnormal rage of mean parenchymal transit time was calculated to be more than 300 sec. Discussion: During the last decade, skeptical questions have raised about the suitability of renogram for deconvolution and validity of transit time parameters. Our experiences have proved that kidney is approximately a linear and stationary system, therefore suitable for deconvolution. The validity of transit time parameters is extremely depended on the validity of software being used. Commercial software usually don’t have sufficient accuracy for calculation of transit times.
similar resources
calculation of 99mtc-dtpa transit times in normal kidney [persian]
introduction: renal dynamic study is a well-established and popular test in routine practice of nuclear medicine. the test is non-invasive, rapid and unique in evaluation of the kidney function. in despite of its clinical values, the parameters derived from renogram are physiologically meaningless. that is due to the fact that renogram is not the true kidney function. from mathematical points o...
full textApplication of 99mTc-DTPA Radiotracer in Persian Cat’s Renal Scintigraphy
Purpose: To evaluate the suitability of Tc-DTPA as a radiotracer in Persian cat's renal scintigraphy. Methods: twelve adult healthy Persian cats were selected. For scintigraphy, the animals were anesthetized and TC-DTPA was injected via the femoral vein as a bolus at a dose of 1.5 mCi. Immediately after intravenous injection of radiotracer, scintigraphic operation was conducted on the renal org...
full textParenchymal mean transit time analysis of 99mTc-DTPA captopril renography.
UNLABELLED Proposed renal hemodynamic mechanisms of captopril suggest that quantitation of renographic retention parameters should help identify patients suspected of having renovascular disease. The parenchymal mean transit time (MTT) is theoretically superior to other measures of retention, but data supporting its superiority are few. METHODS Two groups of subjects were studied with diethyl...
full textGastrointestinal transit measurements in mice with 99mTc-DTPA-labeled activated charcoal using NanoSPECT-CT
BACKGROUND Gastrointestinal (GI) disorders are commonly associated with chronic conditions such as diabetes, obesity, and hypertension. Direct consequences are obstipation or diarrhea as opposite aspects of the irritable bowel syndrome, and more indirectly, alteration of appetite, feeling of fullness, flatulence, bloatedness, and eventually leading to altered absorption of nutrients. Moreover, ...
full textBochdalek hernia with intrathoracic kidney as one of its contents - Incidentally identified by 99mTc-DTPA renogram
Congenital diaphragmatic hernia (CDH) is a rare anomaly with a reported incidence of 1 in 16,000 populations. It may be associated with herniation of stomach, intestinal loops, spleen, and kidney through a chest wall defect. We report a case of a 1 year old male child who presented with recurrent fever, occasional chills and rigor of 4 months duration. Left kidney was non visualised on ultrasou...
full textEffect of Saffron (Crocus Sativus) Administration on Kidney Function in Normal Cats as Determined by Use of 99mTc-DTPA Renal Scintigraphy
Objective- To evaluate and compare kidney function with and without saffron administration and consider the diuretic and nephroprotective effects of aqueous extract of this substance in normal cats. Design- Descriptive study Animals- 6 female healthy cats (age: 2 to 4 years, average weight: 4 kg) - no clinical sign of renal disorders and prior to presentation Procedures- The scintigraphy of r...