Assessment of Patient Absorbed Radiation Dose during Hysterosalpingography: A Pilot Study in Southwest Nigeria

Authors

  • C A Aborisade PhD, Department of Physics and Engineering Physics, Obafemi Awolowo University, Ile-Ife, Osun State, Nigeria
  • J A Achuka PhD, Department of Physics, Covenant University Ota, Ogun State, Nigeria
  • M A Aweda PhD, Department of Radiation Biology, Radiotherapy and Radiodiagnosis, College of Medicine, Lagos University Teaching Hospital, Idi-Araba, Lagos, Nigeria
  • M R Usikalu PhD, Department of Physics, Covenant University Ota, Ogun State, Nigeria
Abstract:

Background: Hysterosalpingography (HSG) is an indispensable tool for diagnosing infertility in females. The procedure exposes female reproductive organs to ionizing radiation as the genitals are irradiated during the process. Investigating patient absorbed dose during the procedures is essential for effective radiological protection of the patient. Objective: This study aims to investigate the radiation dose received by patient during HSG examination in the study environment in order to enhance optimization of procedures and the associated dose, thereby minimizing radiation risks. Material and Methods: The prospective pilot study, was conducted in four tertiary healthcare institutions in Southwest Nigeria. Thermoluminescence dosimeter (TLD 100) was used to determine the Entrance Surface Dose (ESD) of 80 patients presented for HSG investigation. The corresponding effective dose, ovary, uterus and urinary bladder doses were evaluated using PCXMC software. Results: The mean entrance surface doses (ESD) obtained from the four centers were 18.58±6.31 mGy, 15.18±2.27 mGy, 17.44±3.43 mGy and 34.24±11.98 mGy for SW1, SW2, SW3 and SW4 centers, respectively. The corresponding mean of effective doses were 1.54±0.63 mSv, 1.24±0.28 mSv, 1.41±0.30 mSv and 2.53±0.94 mSv for SW1, SW2, SW3 and SW4 centers, respectively. The resulting mean doses to the ovary, urinary bladder and uterus were also presented. Conclusion: The results obtained in general are comparable with international standards. It was, however, recommended that study centers with high doses should conduct dose audit in order to enhance patient safety.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Patient-Specific Radiation Dose and Cancer Risk in Computed Tomography Examinations in Ondo, Nigeria

Introduction: The dose in computed tomography (CT) often approach or exceed the optimum levels, thereby increasing the probability of cancer induction. With wide application of this diagnostic test, it is expedient to determine the effective dose (ED) for each patient to estimate their cancer risk. This study was conducted to investigate the patient-specific dose (PSD) and cancer risk in CT exa...

full text

Assessment of Patient Radiation Dose in Interventional Procedures at Shahid Madani Heart Center in Khorramabad, Iran

Introduction: Coronary angiography is the most common angiographic procedure for diagnosis and treatment of the heart diseases. Herein, we aimed to evaluate the entrance surface dose (ESD), dose area product (DAP), as well as cancer risk in interventional cardiology procedures. Materials and Methods: This study was conducted during July-December 2015 at Shahid Madani Heart Center in Khorramabad...

full text

Absorbed dose to peripheral organs during different methods of dental radiology using radiation estimation models

Introduction: Dental radiography as one of the most frequent type of radiological examinations is accepted for medical investigations due to their significant benefits nevertheless using ionizing radiation. It has lower radiation dose compared to another radiological examination but because of its high application for children, radiation dose needs attention. Based on affectin...

full text

a study of baudrillards ideas in brian moores fiction

پیدایش مرحله ی جدیدی از نظام سرمایه داری بعد از جنگ جهانی دوم همزمان است با ظهور عصر اطلاعات و رسانه جمعی. در چنین جامعه ای سیر آزادانه ی نشانه ها در فضای بی اساس مجازی بر سرعت فرسایش واقعیت می افزاید. به اعتقاد بودریار، فقدان واقعیت به واسطه ی شبیه سازی آن و تولید حاد واقعیت (hyperreality) پنهان خواهد ماند. این پژوهش بر آن است که جامعه فرانوین توصیف شده در سه رمان بریان مور را با توجه به نظر...

15 صفحه اول

Estimation of radiation dose of emergency exposure during the hospitalized 131I therapy patient

Background:  The aim of the study was to estimate the radiation dose during emergency exposure to patients treated with iodine-131 during the isolation period. Materials and Methods: The dose rate from a sample of 192 patients administrated by three different radioactivity of 131I (3.7, 5.55 and 7.4 GBq) was measured, at 1 meter after 1, 24 and 48 hours post dose administration, at three d...

full text

Monte Carlo radiography simulation for assessment of absorbed radiation dose in femur bone marrow during X-ray radiography for constant mAs and AEC techniques

Background: The purpose of this study was to find the accurate absorbed dose in the femur bone marrow during the X-ray radiography for constant mAs and AEC techniques. Materials and Methods: The DOSXYZnrc was used to simulate radiation doses in two human femurs during diagnostic radiography. EGSnrc phantoms produced from actual CT images of human femurs were modified by adding seven micrometre ...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 10  issue 2

pages  131- 140

publication date 2020-04-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023