Assessment of Maximum Entrance Skin Dose of Patients Undergoing Cardiac Interventional Procedures and Its Correlation with Other Dosimetric Parameters

Authors

  • Homa Rezaei Moghaddam Medical Physics Department, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
  • Mohammad Mehrpouyan Radiology and Radiotherapy Department, Faculty of Medicine, Sabzevar University of Medical Sciences, Sabzevar, Iran
  • Mohsen Khosroabadi Medical Physics Department, Faculty of Medicine, North Khorasan University of Medical Sciences, Bojnurd, Iran
Abstract:

Introduction: In recent years, the number of complex coronary angiography (CA) is increasing rapidly. These procedures have a significant contribution to medical exposure to the general population. Exposure of patients to high doses of x-rays could cause deterministic effects on the skin. Therefore, the assessment of radiation doses of patients is of great importance. This study aimed to assess maximum entrance skin dose (MESD) of patients who underwent interventional cardiology procedures. Moreover, it was attempted to determine the correlation between MESD and other relevant dosimetric parameters. Material and Methods: The MESDs of 32 patients who underwent CA procedures were measured by an array of thermoluminescence dosimeters (TLDs). In this study, a Perspex tray consisting of 5 rows and 6 columns was used to hold the TLDs. Its long axis was perpendicular to the long axis of the table, and the top edges of the tray were approximately equal to the patient’s shoulders. Results: The results revealed a linear relationship between dose area product (DAP) values and MESDs (R2=0.89; P=0.00). In addition, there was a significant association between MESD and fluoroscopy time (R2=0.89). Moreover, a weak correlation was observed between MESD and the number of frames per second (R2=0.23). Conclusion: According to the results, the recorded DAP values and fluoroscopy time can be used to estimate the MESDs of patients undergoing coronary fluoroscopy procedures.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Assessment of patients’ entrance skin and effective dose in a mathematical human phantom for the most common interventional radiological examinations

Introduction: Nowadays, we are witnessing an exponential use of interventional radiology techniques in different communities. After CT, interventional techniques are the second factor of increasing patients’ doses in different societies. Measuring patient doses from aforementioned methods has been recommended by many radiation protection professional organizations such as ICRP...

full text

Assessment of patients skin dose undergoing coronary angiography and Percutaneous Transluminal Coronary Angioplasty (PTCA)

Background: Practice of interventional cardiology procedures such as Coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA) has largely increased in recent years and is now changing to a matter of routine in many hospitals. The purpose of this study was to measure skin and organ doses in patients undergoing CA and PTCA and to find a probable relation with c...

full text

Assessment of patient entrance skin dose (ESD) and effective dose (ED) for the most common interventional radiological exams at Mazandaran hospital

Introduction:   Nowadays we are witnessing an exponential application of interventional radiology techniques in various communities as well as Iran. Radiological technique is regarded as  the  2nd  contributing  factor in  increasing  the  amount  of  public  doses  in various societies. So that related radiation protection organization has recommended measuring patient d...

full text

Evaluation of Maximum Patient Skin Dose Arising from Interventional Cardiology Using Thermoluminescence Dosimeter in Mashhad, Iran

Introduction The increasing practice of interventional fluoroscopy in diagnosis and treatment of cardiovascular disease has risen attention to improve radiation protection of patients and cardiologists in these relatively high dose techniques. Therefore, nowadays there is an emphasis on the measurement of radiation dose received by patients and cardiologists arising from the relevant procedures...

full text

Assessment of Patient Radiation Dose in Interventional Procedures at Shahid Madani Heart Center in Khorramabad, Iran

Introduction: Coronary angiography is the most common angiographic procedure for diagnosis and treatment of the heart diseases. Herein, we aimed to evaluate the entrance surface dose (ESD), dose area product (DAP), as well as cancer risk in interventional cardiology procedures. Materials and Methods: This study was conducted during July-December 2015 at Shahid Madani Heart Center in Khorramabad...

full text

Assessment of Patients’ Entrance Skin Dose from Diagnostic X-ray Examinations at Public Hospitals of Akwa Ibom State, Nigeria

Introduction High doses of ionizing radiation can lead to adverse health outcomes such as cancer induction in humans. Although the consequences are less evident at very low radiation doses, the associated risks are of societal importance. This study aimed at assessing entrance skin doses (ESDs) in patients undergoing selected diagnostic X-ray examinations at public hospitals of Akwa Ibom State,...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 17  issue 4

pages  235- 246

publication date 2020-07-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com