Assessment and Comparison of Homogeneity and Conformity Indexes in Step-and-Shoot, Compensator-Based Intensity Modulated Radiation Therapy (IMRT) and Three-Dimensional Conformal Radiation Therapy (3D CRT) in Prostate Cancer

Authors

  • Farid Nezhad Dadgar Farid Nezhad Dadgar, Assistance Prof. of Radiation Oncology, Sina Radiotherapy Oncology Department, Bu Ali Hospital, Islamic Azad University, Medical College, Tehran, Iran.
  • Hassan Ali Nedaie Hassan Ali Nedaie, Assistant Prof. of Medical Physics, Radiotherapy Oncology Department, Tehran University of Medical Sciences, Tehran, Iran.
  • Hossein Hassani Hossein Hassani, M. Sc of Medical Radiation Engineering, Department of Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran.
  • Hussain Gharaati Hussain Gharaati, Prof. of Medical Physics, Radiotherapy Oncology Department, Tehran University of Medical Sciences, Tehran, Iran.
  • Kaveh Shirani Tak Abi Kaveh Shirani Tak Abi, Medical Physicist of Sina Radiotherapy Oncology Department, Bu Ali Hospital, Tehran, Iran.
  • Malihe Rezaie Yazdi Malihe Rezaie Yazdi, Medical physicist of Iran Mehr Radiotherapy Oncology Department, Iran Mehr Hospital, Birjand, Iran.
  • Maryam Rezaie Yazdi Maryam Rezaie Yazdi, Medical physicist of Iran Mehr Radiotherapy Oncology Department, Iran Mehr Hospital, Birjand, Iran.
  • Marzieh Salimi Marzieh Salimi, PhD. Candidate of Medical Physics, Medical Physics and Engineering Department, Tehran University of Medical Sciences, Tehran, Iran.
  • Reza KhodaBakhshi Reza KhodaBakhshi, Radiation Oncologist, Consultant and Executive Director of Sina Radiotherapy Oncology Department, Bu Ali Hospital, Tehran, Iran.
Abstract:

Introduction: Intensity modulated radiation therapy (IMRT) and three-dimensional conformal radiation therapy (3D CRT) are two treatment modalities in prostate cancer, which provide acceptable dose distribution in tumor region with sparing the surrounding normal tissues. IMRT is based on inverse planning optimization; in which, intensity of beams is modified by using multileaf collimators and also compensators with optimum shapes in step and shoot (SAS) and compensator-based method, respectively. Materials and Methods: Prescribed dose was 80 Gy for both IMRT procedures and 70 Gy for 3D CRT. Treatment plans of 15 prostate cancer candidates were compared to target the minimum dose, maximum dose, V 76 Gy (for IMRT plans) V 66.5 Gy (for 3D CRT), mean dose, conformity index (CI), and homogeneity index (HI). Results: Dose conformity in compensators-based IMRT was better than SAS and 3D CRT. The same outcome was also achieved for homogeneity index. The target coverage was achieved 95% of prescribed dose to 95% of planning target volume (PTV) in 3D CRT and 95% of prescribed dose to 98% of PTV in IMRT methods. IMRT increases maximum dose of tumor region, improves CI and HI of target volume, and also reduces dose of organs at risks. Conclusion: Results of this study showed that both IMRT methods provide better target coverage in comparison of 3D CRT. In SAS technique, maximum dose reduced compared with compensator-based IMRT while, in the later method, CI and HI improved; it must be mentioned that 3D CRT also had the acceptable HI and CI results. IMRT approaches represented better homogeneity and conformity over 3D CRT and in comparison of two IMRT methods, all acceptable results can be achieved in compensator IMRT.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Assessment and Comparison of Homogeneity and Conformity Indexes in Step-and-Shoot and Compensator-Based Intensity Modulated Radiation Therapy (IMRT) and Three-Dimensional Conformal Radiation Therapy (3D CRT) in Prostate Cancer

Intensity modulated radiation therapy (IMRT) and three-dimensional conformal radiation therapy (3D CRT) are two treatment modalities in prostate cancer, which provide acceptable dose distribution in tumor region with sparing the surrounding normal tissues. IMRT is based on inverse planning optimization; in which, intensity of beams is modified by using multileaf collimators and also compensator...

full text

Comparison of Radiobiological Models for Radiation Therapy Plans of Prostate Cancer: Three-dimensional Conformal versus Intensity Modulated Radiation Therapy

Purpose: In the current study, using different radiobiological models, tumor control probability (TCP) and normal tissue complication probability (NTCP) of radiotherapy plans were calculated for three-dimensional conformal radiation therapy (3D-CRT) and intensity modulated radiation therapy (IMRT) of prostate cancer.Methods and Materials: 10 prostate plans were randomly selected among patients ...

full text

Radiobiological Model-Based Comparison of Three-Dimensional Conformal and Intensity-Modulated Radiation Therapy Plans for Nasopharyngeal Carcinoma

Introduction: Radiobiological modeling of radiotherapy plans are used for treatment plan comparisons. The current study aimed to compare the three-dimensional conformal radiation therapy (3DCRT) and intensity-modulated radiation therapy (IMRT) plans for nasopharyngeal cancer using radiobiological modeling. Materials and Methods: This study was conducted on 10 patients with nasopharyngeal carci...

full text

3D-Conformal Radiation Therapy and Intensity-Modulated Radiation Therapy Techniques for Laryngeal Cancer Taking Parotid Glands as Organ at Risk

Background: Three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) techniques are used for the treatment of patients with laryngeal cancer. Objective: This study aimed to investigate the effects of these 2 treatment techniques on the planning target volume (PTV) (laryngeal cancer), dose homogeneity, dose of organs at...

full text

Comparison of three dimensional conformal radiation therapy, intensity modulated radiation therapy and volumetric modulated arc therapy for low radiation exposure of normal tissue in patients with prostate cancer.

Radiotherapy has an important role in the treatment of prostate cancer. Three-dimensional conformal radiation therapy (3D-CRT), intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) techniques are all applied for this purpose. However, the risk of secondary radiation-induced bladder cancer is significantly elevated in irradiated patients compared surgery-only ...

full text

Respiratory motion effect on tumor and normal tissue doses in patients with lung cancer, treated with Intensity Modulation Radiation Therapy and Three Dimensional Conformal Radiation Therapy.

Introduction:   The aim of this study is to investigate the effect of respiratory motion during radiation therapy in patient with lung cancer and comparison of dosimetric parameters between Intensity modulation radiation therapy and three-dimensional conformal radiotherapy in lung cancer.   Materials and Methods:   Two CT scan was performred for each pati...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 15  issue Special Issue-12th. Iranian Congress of Medical Physics

pages  406- 406

publication date 2018-12-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023