Application of Ion - Imprinted Polymer Synthesized as New Sorbent for Preconcentration and Separation of Thallium (I) and Its Determination by Electrothermal Atomic Absorption Spectroscopy
Authors
Abstract:
At this study, thallium (I) ion-imprinted polymer, as a novel sorbent for Tl (I) and comparison with Tl(III) ion-imprinted polymer has been synthesized. This sorbent for preconcentration and solid-phase extraction of Tl(I) ions from aqueous solutions, used. Through preparing the binary complex of Tl(I) ions with 5, 7-dichloroquinoline-8-ol (DCQ) the particles of thallium (I) Ion-Imprinted Polymer (IIP) have synthesized. In the presence of 2-methoxyethanole (porogen) and 2, 2ó-azobisisobutyronitrile (initiator, AIBN) Thermal copolymerization of methyl methacrylate (functional monomer, MMA) and ethyleneglycoldimethacrylate(cross-linkingmonomer, EGDMA) have done. The imprinted ion has removed from the polymer by removing the above particles with 1 mol/L HNO3 to obtain the leached IIP particles. Similarly, Control Polymer (CP) particles, have prepared without thallium (I) ions. The characterization of unleached and leached IIP particles was done by, Fourier-Transform InfraRed (FT-IR) spectroscopy, Brunauer-Emmett-Teller (BET), surface area analysis, and X-Ray Diffraction (XRD). As a function of pH, the preconcentration of thallium (I) has studied during rebinding with the leached IIP particles, for determination of thallium in aqueous solution, the weight of the polymer material, the elution and preconcentration times, the concentration of eluent(nitric acid), the volume of the aqueous phase and the volume of an eluent. ElectroThermal Atomic Absorption Spectrometry (ETAAS) has utilized. The method's Detection limit was 0.1 mg/ mL, while the relative standard deviation for five times repeat was 3.5%.
similar resources
Determination of Cadmium by Electrothermal Atomic Absorption Spectrometry after its Separation and Preconcentration by Syringe to Syringe Dispersive Liquid Phase Microextraction-Solidified Floating Organic Drop
The application of syringe to syringe dispersive liquid phase microextraction-solidified floating organic drop was extended for the separation and preconcentration of trace amounts of cadmium ions from water and cereal samples. The extracted cadmium was quantified by electrothermal atomic absorption spectrometry. Factors affecting the complex formation as well as microextraction efficiency such...
full textAutomated on-line separation–preconcentration system for platinum determination by electrothermal atomic absorption spectrometry
A flow injection on-line sorption preconcentration system for the electrothermal atomic absorption spectrometric determination of platinum has been developed. The method employs on-line preconcentration of platinum on a column packed with silica gel functionalised with 1,5-bis(di-2-pyridyl)methylene thiocarbohydrazide (DPTH-gel) placed in the autosampler arm. The modification of the autosampler...
full textExtraction separation and electrothermal atomic absorption spectrometric determination of thallium in some sulfide minerals.
A method for thallium determination in some sulfide minerals (sphalerite, galena, orpiment and realgar) by electrothermal atomic absorption spectrometry has been proposed. Mineral samples were dissolved in a mixture of HNO3 and HCl. The effect of interfering elements (Zn, Pb and As) on the determination of Tl in the investigated minerals was studied. These investigations show that it is not pos...
full textPreconcentration and Determination of Lead for Trace Levels in Water and Wastewater Samples by Vortex-Assisted Microextraction Using TPAS as a New Synthetic Complexing Agent with Electrothermal Atomic Absorption Spectroscopy Detection
A simple and rapid solidified vortex assisted 1-undecanol based liquid-liquid microextraction technique was proposed for preconcentration of trace levels of lead ions. The extraction solvent (1-undecanol) was dispersed into the aqueous samples by the assistance of vortex agitator. 100 µL of 1-undecanol containing ethyl (2Z)-3-[(5-chloro-7-methyl[1,3]thiazolo[5,4-d]pyrimidi...
full textapplication and construction of carbon paste modified electrodes developed for determination of metal ions in some real samples
ساخت الکترودهاِی اصلاح شده ِیکِی از چالشهاِی همِیشگِی در دانش شیمِی بوِیژه شیمِی تجزیه مِی باشد ،که با در نظر گرفتن سادگِی ساخت، کاربردی بودن و ارزان بودن روش مِی توان به باارزش بودن چنِین سنسورهاِی پِی برد.آنچه که در ادامه آورده شده به ساخت و کاربرد الکترودهاِی اصلاح شده با استفاده از نانو ذرات در اندازه گِیرِی ولتامترِی آهن وکادمِیم اشاره دارد. کار اول اختصاص دارد به ساخت الکترود خمِیر کربن اصلاح شده با لِیگاند داِ...
15 صفحه اولIndirect Determination of Ascorbic Acid by Atomic Absorption Spectroscopy
A new and simple method followed by atomic absorption spectrometry has been developedfor indirect determination of ascorbic acid (AA). The proposed method was based on the oxidationof AA to dehydroascorbic acid with Cu2+cation(200mgL-1)in an ammonium thiocyanatesolution atpH2.4. AA reduces Cu2+to Cu+followed by the precipitation of Cu+ with SCN-. Then, the excess ofCu2+in the solution was measu...
full textMy Resources
Journal title
volume 39 issue 1
pages 59- 66
publication date 2020-02-01
By following a journal you will be notified via email when a new issue of this journal is published.
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023