Application of FFT Cyclic Voltammetry for Monitoring Removal of Mercury Ions from Aqueous Environment using New Adsorbent based Modified Mesoporous Silica (SBA–15)

Authors

  • Gholam Reza Nabei School of Environment, College of Engineering, University of Tehran, P. O. Box 14155-6135, Tehran, Iran
  • Hamid Rashedi School of Chemical Engineering, College of Engineering, University of Tehran, Tehran, Iran
  • Mehdi Esmaeili Bidhendi School of Environment, College of Engineering, University of Tehran, P. O. Box 14155-6135, Tehran, Iran
  • Naser Mehrdad School of Environment, College of Engineering, University of Tehran, P. O. Box 14155-6135, Tehran, Iran
Abstract:

As the electrochemical method, the Fast Fourier Transform (FFT) Stripping Cyclic Voltammetry detection method was designed for measurement and monitoring of adsorbed mercury ions by new modified adsorbent based on mesoporous silica as a new adsorbent. In this respect, SBA-15 as mesoporous silica and 1, 3, 5 Trithiane as effective modifier ligand were chosen, and the modification process was carried out physically. Continuing research application of modified mesoporous silica for the removal of mercury ions (Hg2+) from the aquatic environment in different pH, the weight of adsorbent and, stirring time as the major parameters were investigated and analysis of flow-injection was used as the major method for determination of adsorbed mercury ions by modified SBA-15. Also, a special computer numerical technique is used to calculate Hg response based on the total charge exchange at the electrode surface, where the currents were integrated into the range of reduction of Hg. The time for stripping was less than 300 ms. The results showed that the best Hg2+ ions removal conditions were achieved at the 15.0 mg of modified adsorbent, pH 5.0 and stirring time 15 min; Also the maximum percentage removal of Hg2+ ions and the capacity of the adsorbent were found to be 85% and 10.6 mg of Hg2+ ions /g modified SBA-15, respectively.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Modified Mesoporous Silica (SBA–15) with Trithiane as a new effective adsorbent for mercury ions removal from aqueous environment

BACKGROUND Removal of mercury from aqueous environment has been highly regarded in recent years and different methods have been tested for this purpose. One of the most effective ways for mercury ions (Hg(+2)) removal is the use of modified nano porous compounds. Hence, in this work a new physical modification of mesoporous silica (SBA-15) with 1, 3, 5 (Trithiane) as modifier ligand and its app...

full text

Synthesis of Ethylenediamine-modified Ordered Mesoporous Carbon as a New Nanoporous Adsorbent for Removal of Cu(II) and Pb(II) Ions from Aqueous Media

The mesoporous carbon (CMK-3) functionalized with ethylenediamine (EDA) has been synthesized (CMK-3-EDA) and applied as a new mesoporous adsorbent for removal of Cu(II) and Pb(II) cations from aqueous solutions. Nitrogen adsorption–desorption measurements (BET) show that surface area, pore size and pore volume of CMK-3 were significantly changed after amine modification. The BET surface area an...

full text

application and construction of carbon paste modified electrodes developed for determination of metal ions in some real samples

ساخت الکترودهاِی اصلاح شده ِیکِی از چالشهاِی همِیشگِی در دانش شیمِی بوِیژه شیمِی تجزیه مِی باشد ،که با در نظر گرفتن سادگِی ساخت، کاربردی بودن و ارزان بودن روش مِی توان به باارزش بودن چنِین سنسورهاِی پِی برد.آنچه که در ادامه آورده شده به ساخت و کاربرد الکترودهاِی اصلاح شده با استفاده از نانو ذرات در اندازه گِیرِی ولتامترِی آهن وکادمِیم اشاره دارد. کار اول اختصاص دارد به ساخت الکترود خمِیر کربن اصلاح شده با لِیگاند داِ...

15 صفحه اول

Mercury removal from aqueous solutions by palm leaves adsorbent

Mercury is a carcinogenic and teratogenic compound that tends to accumulate in water solutions. In this research, the removal of mercury from an aqueous solution was evaluated by using palm leaves. Experiments were performed to study the adsorption efficiency, the effect of the adsorbent amount, the balance time, the adsorbate concentration, and the pH on mercury removal. The experimental appar...

full text

Application of modified bentonite using sulfuric acid for the removal of hexavalent chromium from aqueous solutions

Background: Environmental contamination by chromium (Cr) has become an important issue due to its adverse effects on human health and environment. This study was done to evaluate the application of modified bentonite using sulfuric acid as an adsorbent in the removal of hexavalent Cr from aqueous solution. Methods: Adsorbent features were determined using x-ray diffraction (XRD), fourier transf...

full text

application of upfc based on svpwm for power quality improvement

در سالهای اخیر،اختلالات کیفیت توان مهمترین موضوع می باشد که محققان زیادی را برای پیدا کردن راه حلی برای حل آن علاقه مند ساخته است.امروزه کیفیت توان در سیستم قدرت برای مراکز صنعتی،تجاری وکاربردهای بیمارستانی مسئله مهمی می باشد.مشکل ولتاژمثل شرایط افت ولتاژواضافه جریان ناشی از اتصال کوتاه مدار یا وقوع خطا در سیستم بیشتر مورد توجه می باشد. برای مطالعه افت ولتاژ واضافه جریان،محققان زیادی کار کرده ...

15 صفحه اول

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 12  issue 7

pages  1002- 1013

publication date 2020-07-31

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023