Application of Differential Kinetic Method Using ANN with a New Synthetic Reagent for Simultaneous Spectrophotometric Determination of Mercury and Palladium
Authors
Abstract:
A new selective reagent was used for simultaneous determination of mercury and palladium in real samples with their different kinetic spectrophotometric properties. The method is based on the difference in the rate of the oxidation reaction of the recently synthesized reagent, nitro benzoyl diphenylmethylen phosphorane (N-BDMP), with Hg2+ and Pd2+. The kinetic profiles were monitored and recorded at maximum wavelength of reagent, and the data obtained from the experiments were processed by a chemometric approach (principal component analysis-artificial neural network models (PCFFNNs)). Performances of the proposed method were tested with regard to relative standard error (RSE), using synthetic solutions. Under the working conditions, the proposed method was successfully applied to the simultaneous determination of Hg2+ and Pd2+ in water, waste water and urine samples. The results showed that mercury and palladium could be determined simultaneously in the range of 4.00×10-7 to 1.00×10-4 mol L-1(0.08 to 20.06 μg mL-1) and 1.00×10-6 to 1.00×10-4 mol L-1 (0.11 to 10.64μg mL-1), respectively. Investigation of the effect of other metals on the system shows that this reagent is very selective for these two analytes and other metal ions do not show any interference.
similar resources
application of differential kinetic method using ann with a new synthetic reagent for simultaneous spectrophotometric determination of mercury and palladium
full text
Kinetic Spectrophotometric Method for Determination of S032- Using Methylen blue
The present work reports a kinetic spectrophotometric method for the determination of traceamounts of sulphite that is based on inhibitory effect of sulphite on the oxidation of Methyleneblue (MB) in acidic media. The reaction is followed spectrophotometrically by monitoring thedecrease in absorbance of MB at 664 nm with a fixed time of 0.5-4.5 minutes. It was found thatsulphite exert a strong ...
full textSpectrophotometric Simultaneous Kinetic Determination of Iodide and Iodate Using Partial Least-Squares Calibration Method in a Single Kinetic Run
A rapid, sensitive and versatile kinetic method is presented for the simultaneous spectrophotometric determination of iodide and iodate by partial least-squares regression (PLS) using original and derivate data named as absorbance and rate data. The method is based on the catalytic effect of the cited anions on the reaction rate between Ce(IV) and As(III) in 2 mol l?1 sulfuric acid medium. The ...
full textmultiwavelength pectrophotometric determination of stability constants of 4-(2– thiazolylazo) resorcinol (tar) with la3+, y3+ and th4+ in organic-water mixed solvents by chemometrics method & simultaneous spectrophotometric determination of lead, copper and nickel using xylenol orange by partial least squares calibration method
تشکیل کمپلکس های tarبا یون های لانتانیم, ایتریم و توریم در دمای 25 درجه، قدرت یونی ثابت 0.1 مولار و در ph ثابت در مخلوط حلال های اتانول – آب و استونیتریل – آب با استفاده از روش های اسپکتروفوتومتری مورد بحث و بررسی قرار گرفت. داده های اسپکتروفوتومتری با استفاده از نرم افزار squad پردازش شدند تا ثابت های تشکیل کمپلکس اندیکاتور – فلز را محاسبه کند. نتایج نشان می دهد که درصد حلال آلی در مخلوط حلال ...
15 صفحه اولapplication and construction of carbon paste modified electrodes developed for determination of metal ions in some real samples
ساخت الکترودهاِی اصلاح شده ِیکِی از چالشهاِی همِیشگِی در دانش شیمِی بوِیژه شیمِی تجزیه مِی باشد ،که با در نظر گرفتن سادگِی ساخت، کاربردی بودن و ارزان بودن روش مِی توان به باارزش بودن چنِین سنسورهاِی پِی برد.آنچه که در ادامه آورده شده به ساخت و کاربرد الکترودهاِی اصلاح شده با استفاده از نانو ذرات در اندازه گِیرِی ولتامترِی آهن وکادمِیم اشاره دارد. کار اول اختصاص دارد به ساخت الکترود خمِیر کربن اصلاح شده با لِیگاند داِ...
15 صفحه اولdevelopment of different optical methods for determination of glucose using cadmium telluride quantum dots and silver nanoparticles
a simple, rapid and low-cost scanner spectroscopy method for the glucose determination by utilizing glucose oxidase and cdte/tga quantum dots as chromoionophore has been described. the detection was based on the combination of the glucose enzymatic reaction and the quenching effect of h2o2 on the cdte quantum dots (qds) photoluminescence.in this study glucose was determined by utilizing glucose...
My Resources
Journal title
volume 7 issue 2
pages 75- 87
publication date 2013-11-01
By following a journal you will be notified via email when a new issue of this journal is published.
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023