Aortic Valve replacement with Reduction Aortoplasty with Mesh Prosthesis in 75 years old with Sever aortic Regurgitation with Aortic Aneurysm

Authors

  • Aliasghar Moeinipour Cardiac Surgeon, Department of Cardiac Surgery, Faculty of Medical Science. Mashhad University of Medical Sciences, Mashhad, Iran.
  • Hamid Hoseinikhah Cardiac Surgeon, Department of Cardiac Surgery, Faculty of Medical Science. Mashhad University of Medical Sciences, Mashhad, Iran.
  • Mohammad Abbassi Teshnisi Cardiac Surgeon, Department of Cardiac Surgery, Faculty of Medical Science. Mashhad University of Medical Sciences, Iran.
  • Omid Javdanfar Resident of Cardiac Surgery, Department of Cardiac Surgery, Faculty of Medical Science, Mashhad University of Medical Sciences, Mashhad, Iran
Abstract:

Although classic and standard procedure for patients with ascending Aorta aneurysm with Sever aortic Regurgitation is Bentall surgery but in some selected cases this complex surgery was not performed with different reason like advanced age and coexisting comorbidity involving renal and hepatic and lung Function. In our cases 75 years old man with chronic renal failure ( Cr= 3.2 ) who was known case of sever aortic Regurgitation and Ascending Aortic Aneurysm with 5.5 diameter.replacement of Aortic Valve with Biologic Prosthesis Aortic Valve and Reduction Aortoplasty with Mesh prosthesis was done successfully with good result with early follow up.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Successful use of reduction aortoplasty in patients undergoing aortic valve replacement with ascending aortic dilatation.

Results We identified 26 patients who underwent aortoplasty during aortic valve replacement. Age (66 ± 13 years), sex (male: female, 15:11), euroscore (5 ± 3), bypass time (95 ± 18 min), xclamp time (68 ± 13 min). Native valve pathology (stenosis: regurgitation: mixed, 13:4:9). Type of implant (mechanical: biological, 13:13). Median prosthetic valve size was 25 mm in all patients. Post-operativ...

full text

Aortic root replacement with a freestyle stentless valve for aortitis syndrome with ascending aortic aneurysm and aortic regurgitation.

A 47-year-old woman who had been diagnosed as having aortitis syndrome underwent aortic root replacement for an ascending aortic aneurysm and aortic regurgitation. Because the patient has been treated with steroids for more than 20 years, a Freestyle stentless valve was used to avoid the risk of valve detachment. There were no complications observed during the postoperative course. Although lon...

full text

Quadricuspid aortic valve with aortic regurgitation.

A 51-year-old man presented to the hospital with symptoms suggestive of an embolic stroke, including slurred speech. The patient’s history included mild aortic regurgitation, which was detected by means of transthoracic echocardiography 3 months before presentation. Transesophageal echocardiographic findings confirmed mild aortic regurgitation (panel A) and revealed a quadricuspid aortic valve ...

full text

A rare case of prosthetic aortic valve endocarditis complicated with multiple fistula to peri aortic structure

  Multiple aorto-cardiac cavity communications is very rare but important complication of prosthetic aortic valve endocarditis. The case below illustrates multiple aorto-cardiac cavity fistula formation following prostethic aortic valve endocarditis presented with slowly progressive symptoms of heart failure. A brief review of surgical reconstruction and the existing literature are presented, i...

full text

Reduction aortoplasty with external wrapping associated with aortic valve replacement in high-risk patients.

OBJECTIVE To assess the midterm follow-up of reduction aortoplasty with external wrapping associated with aortic valve replacement in high risk patients. METHODS Six patients with ascending aortic aneurysm and aortic valve disease were included in this study. Four of them were male. The age ranged from 61 to 70 years (mean 65.7 years). One patient presented severe mitral valve insufficiency. ...

full text

Ascending aortic replacement with aortic valve reimplantation.

BACKGROUND Reimplantation of the native, structurally intact aortic valve within a Dacron tube graft in patients with aortic root aneurysms corrects annular ectasia and dilatation of the sinotubular junction. The durability of this valve repair with respect to the increased mechanical stress on valve cusps has been discussed, is quite controversial, and is yet unknown. METHODS AND RESULTS Fro...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 8  issue 3

pages  662- 665

publication date 2020-09-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023