Analysis of Hip Joint Dose in Prostate Cancer Radiation Therapy: A Dosimetric Comparison of Treatment Plans

Authors

  • Pourfallah, Tayyeb 1Associate Professor, Department of Biochemistry, Biophysics and Genetics, Faculty of Medicine, Mazandaran University of Medical Sciences, Sari, Iran,
  • Ahmadi, Amirhossein Medical Student, Faculty of Medicine, Mazandaran University of Medical Sciences, Sari, Iran
  • Davodian, Saeed Radiation Oncologyst, Imam Khomeini Hospital, Mazandaran University of Medical Sciences, Sari, Iran
  • Seifi Makrani, Danial Phd Student in Medical Physics, Faculty of Medicine, Tehran University of Medical Sciences, Tehran, Iran
Abstract:

Background and purpose: Radiation therapy as a part of cancer treatment is used in almost 50-60% of involved cases. In prostate cancer radiation therapy, a large volume of pelvis is irradiated, so, it is necessary to preserve sensitive organs around the treatment area, especially rectum and bladder. In this study, some dosimetric parameters such as minimum dose (Dmin), maximum dose (Dmax), mean dose (Dmean) to target (PTV) and organs at risk (OAR), Integral dose, Homogeneity Index and Conformity Index were compared between two techniques. Materials and methods: In this analytical study, computed tomography scans of 50 patients (mean age: 52 years) attending Sari Imam Khomeini Hospital were acquired and transferred to the 3D treatment planning system (TPS). For each patient, a conventional plan (Box Fields) and modified oblique four-field (MOFF) plan were prepared using TPS for 15 MV photon energy. A total dose of 7200 cGy was prescribed for each patient. Data analysis was carried out in SPSS applying paired-t-test. Results: In current study, 15-MV energies for radiation of pelvis and bladder using box radiation fields (routine plan) lead to maximum uniformity and homogeneity of dose in irradiated tumor tissue. The results also showed that 15-MV energies for radiation of pelvis and bladder and the new plan could decrease the average integrated dose in femur heads. Conclusion: We observed a significant effect of the geometrics of radiation fields on distribution of dose in tumor tissue and also the amount of dose received by organs at risk in radiotherapy of patients with prostate cancer.  

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Radiation treatment planning for prostate cancer: A new dosimetric comparison of five and seven fields IMRT plans

Background: To compare the dosimetric coverage of the planning target volume (PTV) and the dose delivered to the main Organs at Risk (OARs) in 5 and 7-field techniques of Intensity Modulated Radiation Therapy (IMRT) in patients with local prostate cancer. Materials and Methods: Twelve patients with local prostate cancer underwent 5 and 7-field IMRT planning. The delivery of IMRT was carried out...

full text

Dosimetric Comparison of Various Radiotherapeutic Treatment Plans Using Cobalt-60 and Linac for Prostate Cancer

Introduction: This study was designed to evaluate dosimetric parameters such as rectal dose, bladder dose, integral dose (ID), homogeneity index (HI) and conformity index (CI) in various treatment plans for prostate cancer. Materials and Methods: Pelvic computed tomography (CT) scans of 27 patients were acquired and transferred to the RTDosePLAN treatment planning system. For each patient, 8 co...

full text

Comparison of Radiobiological Models for Radiation Therapy Plans of Prostate Cancer: Three-dimensional Conformal versus Intensity Modulated Radiation Therapy

Purpose: In the current study, using different radiobiological models, tumor control probability (TCP) and normal tissue complication probability (NTCP) of radiotherapy plans were calculated for three-dimensional conformal radiation therapy (3D-CRT) and intensity modulated radiation therapy (IMRT) of prostate cancer.Methods and Materials: 10 prostate plans were randomly selected among patients ...

full text

Dosimetric comparison of treatment of left breast cancer using two different dose schedules Dosimetric comparison of treatment of left breast cancer using two different dose schedules

Background: To date, different kinds of treatment methods have been proposed for radiotherapy of cancer patients. Choosing the kind of treatment method affects the quality of the patient's treatment. This study aims to investigate the effect of the number of radiation treatment sessions on the dose received by the patient and the distribution of tumor dose and dose received by organs at risk in...

full text

Dosimetric comparison of TomoDirect and TomoHelical plans in post-mastectomy chest wall radiation therapy

Background: The purpose of this study was to evaluate the characteristics of TomoDirect (TD) plans compared to conventional TomoHelical (TH) plans in chest wall irradiation in patients with breast cancer. Materials and Methods: TD and TH plans for only chest wall were retrospectively created for 30 patients previously treated with TH technique in our clinic. The beam angles were arranged to cov...

full text

dosimetric comparison of various radiotherapeutic treatment plans using cobalt-60 and linac for prostate cancer

introduction: this study was designed to evaluate dosimetric parameters such as rectal dose, bladder dose, integral dose (id), homogeneity index (hi) and conformity index (ci) in various treatment plans for prostate cancer. materials and methods: pelvic computed tomography (ct) scans of 27 patients were acquired and transferred to the rtdoseplan treatment planning system. for each patient, 8 co...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 31  issue 197

pages  123- 131

publication date 2021-05

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

No Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023