Accuracy and precision of measurements obtained from conventional cephalograms and CBCT scan in orthodontics linear diagnostic measurements

Authors

  • Faegheh Gholinia Dental Sciences Research Center, Department of Orthodontics, School of Dentistry, Guilan University of Medical Sciences, Rasht, Iran
  • Mahsa Pourgholi Dentist
Abstract:

Background and Purpose:  Due to the important role of imaging in the diagnosis and treatment plan in orthodontics, CBCT (Cone Beam Computed Tomography) images because of their three-dimensional nature, can minimize the disadvantages of two-dimensional images such as magnification, distortion, or superimposition. The purpose of this study was to evaluate the accuracy of conventional cephalograms and CBCT scan measurements in linear orthodontic diagnostic measurements. Materials and methods: In the first part, the distances between the 14 anatomical landmarks on the 5 dried human skulls (reference models) identified by metal spheres were measured by a digital caliper. In the next step, CBCT images were scanned from the same reference models. In the second part, radiographic images were taken from 26 patients enrolled according to inclusion and exclusion criteria in three stages, scanning CBCT images, digital LC (Lateral Cephalometric) images from the same CBCT images, manual tracing of digital LC images. Finally, using the obtained data, the accuracy of measurements performed directly on the reference models with CBCT images as well as the CBCT images, digital LC and traced digital LC images of the patients were evaluated together. Results: The mean of direct measurements on the reference models was not significantly different from the measured values on CBCT images (ρ-value> 0.05). In other words, the measurement of the CBCT images was the same as the reference models. Also, in most cases, linear measurements between the traced LC image with digital LC images and the CBCT of patients were different (ρ-value > 0.05). Meaning traced LC images and digital LC in 8 cases, CBCT and digital LC in 4 cases and finally traced digital LC and CBCT in 5 cases were different. Conclusion: The present study showed that the accuracy of CBCT image measurements was similar to the direct measurements obtained from the reference models. Also, the accuracy of linear measurements of CBCT images is higher and more reliable than that of digital LC images as well as traced digital LC images.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Accuracy of Linear Cephalometric Measurements with Scanned Lateral Cephalograms

Digital Cephalometry needs to be as accurate as conventional cephalometry in order to be taken as a standard of care in contemporary orthodontics. Objective of this study was to compare the accuracy of linear cephalometric measurements on scanned cephalograms with manual tracing as the gold standard. Cephalometric analysis of specified linear measurements was performed on cephalometric radiogra...

full text

Analysis of the accuracy of linear measurements obtained by cone beam computed tomography (CBCT-NewTom).

OBJECTIVES The conical beam computed tomography (CBCT) technique presents an innovation of tomographic imaging systems and subsequent volumetric image reconstruction for dentistry. When compared with other methods of tomographic imaging CBCT is characterized by rapid volumetric image acquisition from a single low radiation dose scan of the patient. The NewTom (NewTom 9000; Quantitative Radiolog...

full text

Investigation of the effect of slice thickness and Kvp changes on the accuracy of linear measurements in CBCT: In vitro study

Background and Aim: The accuracy of linear measurements in CBCT images is one of the critical parameters in treatment planning. Slice thickness and exposure parameters seem to affect the accuracy of linear measurements. In this study, we investigated the impact of the above factors on the accuracy of linear measurements in CBCT. Materials and Methods: For the in vitro experiment, three dry huma...

full text

synthesis of sulfides from alcohols and thiols in solvent-freeconditions and deoxygenation of sulfoxides

کاتالیست یک سنتز جدید برای تیواترها توصیف شده است. واکنش الکل ها با آریل، هتروآریل و آلکیل تیو ل ها درحضور 1،3،5- تری آزو- 2،4،6- تری فسفرین-2،2،4،4،6،6 هگزاکلراید ((tapc به عنوان یک کاتالیست موُثر، بازده های خوب تا عالی از تیواترها را حاصل می کند. علاوه براین، واکنش تحت شرایط بدون فلز و بدون حلال پیش می رود، بنابراین یک مکمل جالب برای روش های شناخته شده سنتز تیواترها ارائه می دهد. یک مکانیسم ا...

15 صفحه اول

Evaluation of diagnostic accuracy and dimensional measurements by using CBCT in mandibular first molars

BACKGROUND This study aimed to assess the diagnostic accuracy of cone beam computed tomography (CBCT) and quantitatively evaluate the morphology of mandibular first molars using CBCT. MATERIAL AND METHODS Twenty-four double-rooted mandibular first molars were evaluated by NewTom VGi CBCT. The distance from the furcation and apex to the cementoenamel junction (CEJ), diameter and thickness of c...

full text

Dental measurements and Bolton index reliability and accuracy obtained from 2D digital, 3D segmented CBCT, and 3d intraoral laser scanner

Background To compare the reliability and accuracy of direct and indirect dental measurements derived from two types of 3D virtual models: generated by intraoral laser scanning (ILS) and segmented cone beam computed tomography (CBCT), comparing these with a 2D digital model. Material and Methods One hundred patients were selected. All patients' records included initial plaster models, an intr...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 9  issue 1

pages  0- 0

publication date 2020-02

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023