A novel sensor based on a heterocyclic ionophore for cerium (III) analysis in real samples
Authors
Abstract:
A new polyvinyl choloride (PVC) membrane sensor for cerium(III) was prepared based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane (kryptofix22DD) as an ionophore. The sensorexhibites a linear concentration range of 1.0×10-6 to 1.0×10-1 M, with aNernstian slope of 18.0±1.0 mV/decade, and a detection limit of 9.7×10-7M. It has a fast response time (5 s) and can be used for two monthswithout any considerable divergence in its potential. The proposedsensor revealed high selectivity toward Ce3+ ion with respect to somealkali, alkaline earth and transition metal cations. It could be used in awide pH range of 2.0-11.0. The sensor was successfully used as anindicator electrode in potentiometric titration of Ce3+ ion withethylenediaminetetraacetic acid (EDTA) and sodium iodide (NaI)solutions, and in determination of Ce (III) concentration in real samples.
similar resources
Lanthanum(III) Ion Selective Electrode Based on a New Ionophore
A PVC membrane electrode based on 1-[({[(butylsulfunyl)carbothioyl]disulfanyl} carbothioyl)sulfanyl]butane as a suitable ion carrier for determination of lanthanum(III) ion was prepared. This electrode revealedsuch a good selectivity toward La3+ ion over a wide variety of other metal ions. Some experimental parametersuch as membrane composition, nature, and amount of plasticizer, the amount of ...
full textHighly selective and sensitive sensor based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane as a heterocyclic ionophore
A new polyvinyl choloride (PVC) membrane sensor for cerium (III) was prepared based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane (kryptofix22DD) as an ionophore. The sensor exhibites a linear concentration range of 1.0×10-6to 1.0×10-1M, with a Nernstian slope of 18.0±1.0 mV/decade, and a detection limit of 9.7×10-7M. It has a fast response time (5 s) and can be used for two mont...
full textDetermination of trace amounts of Ag (I) in waste water samples by a novel potentiometric sensor based on perphenazine as an ionophore
Background and Objective: Silver is a toxic heavy metal that is used in various industries and has adverse effects on both human health and the environment. In this respect its determination with sensitive and economic analytical methods is of great importance. Materials and Methods: In this research, a novel ion selective electrode based on perphenazine as an ionophore was developed for deter...
full textlanthanum(iii) ion selective electrode based on a new ionophore
a pvc membrane electrode based on 1-[({[(butylsulfunyl)carbothioyl]disulfanyl} carbothioyl)sulfanyl]butane as a suitable ion carrier for determination of lanthanum(iii) ion was prepared. this electrode revealedsuch a good selectivity toward la3+ ion over a wide variety of other metal ions. some experimental parametersuch as membrane composition, nature, and amount of plasticizer, the amount of ...
full texta time-series analysis of the demand for life insurance in iran
با توجه به تجزیه و تحلیل داده ها ما دریافتیم که سطح درامد و تعداد نمایندگیها باتقاضای بیمه عمر رابطه مستقیم دارند و نرخ بهره و بار تکفل با تقاضای بیمه عمر رابطه عکس دارند
My Resources
Journal title
volume 3 issue 2
pages 18- 28
publication date 2013-06-01
By following a journal you will be notified via email when a new issue of this journal is published.
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023