A novel isolated dual perfusion/superfusion heart model for physiological and pharmacological evaluation of mammalian heart preparations
Authors
Abstract:
Abstract Introduction: Isolated perfused heart models such as perfusion and superfusion are commonly used for mammalian heart research. However, there are several fundamental limitations in the current techniques. In perfusion model, a suitable cannula is connected to the aorta and the perfusion is retrogradely performed. But, electrode displacement is a potential unwanted event resulted from heart contractions. In superfusion model, atrioventricular node (AV) node area is completely visible and fixed in the tissue bath after appropriate preparation, but tissue ischemia is inevitable due to the absence of cell to cell nutrition. The aim of the present study was to create a novel isolated dual perfusion/superfusion model to be used in heart physiological and pharmacological studies. Methods: The rabbit hearts (n=10) were excised. After preparation of proper sections, the electrodes were attached till the steady state appeared. The stimulation protocols consisting Wenckebach and recovery were then carried out during the isolated dual perfusion/superfusion as well as perfusion and superfusion models. Results: The AV node conduction time was increased from 33±4 ms in the isolated dual perfusion/superfusion heart model to 43±5 and 52±5 ms in perfusion and superfusion models, respectively (P<0.05). In addition, Wenckebach cycle length, effective and functional refractory periods were increased in perfusion and superfusion models compared to the isolated dual perfusion/superfusion model (P<0.05). Conclusion: This study shows the superiority of the isolated dual perfusion/superfusion heart model in tissue nutrition compared to the other common methods of mammalian heart studies.
similar resources
effect of low temperature on isolated mammalian heart
effect of perfusion with low temperature locke solution on the isolated hearts of adult rabbits and mongrel puppies was studied. the study showed no arrhythmias or myocardial fibrillation at low temperatures in the isolated mammalian heart.
full textA Novel Fuzzy Based Method for Heart Rate Variability Prediction
Abstract In this paper, a novel technique based on fuzzy method is presented for chaotic nonlinear time series prediction. Fuzzy approach with the gradient learning algorithm and methods constitutes the main components of this method. This learning process in this method is similar to conventional gradient descent learning process, except that the input patterns and parameters are stored in mem...
full textthe innovation of a statistical model to estimate dependable rainfall (dr) and develop it for determination and classification of drought and wet years of iran
آب حاصل از بارش منبع تأمین نیازهای بی شمار جانداران به ویژه انسان است و هرگونه کاهش در کم و کیف آن مستقیماً حیات موجودات زنده را تحت تأثیر منفی قرار می دهد. نوسان سال به سال بارش از ویژگی های اساسی و بسیار مهم بارش های سالانه ایران محسوب می شود که آثار زیان بار آن در تمام عرصه های اقتصادی، اجتماعی و حتی سیاسی- امنیتی به نحوی منعکس می شود. چون میزان آب ناشی از بارش یکی از مولفه های اصلی برنامه ...
15 صفحه اولNew manifestations of electrophysiological remodeling of heart during experimental model of atrial fibrillation in cirrhotic rat isolated heart
Introduction: The present study is aimed to evaluate electrophysiological remodeling of atrioventricular (AV) node and ventricular conduction during experimental atrial fibrillation (AF) model in isolated heart of cirrhotic rats. Methods: Cirrhosis-induced electrophysiological remodeling was evaluated in 24 isolated retrogradely perfused rat hearts in 2 groups (control and cirrhotic). Cirrho...
full textPerformance Evaluation of a Novel Potentiometric Membrane Sensor for Determination of Atorvastatin in Pharmaceutical Preparations
A novel potentiometric ion-selective PVC membrane sensor for analysis of atorvastatin (AT) in pharmaceutical preparations based on atorvastatin-(tetraphenyl borate), (AT-(TPB)2) as sensing element, tetraphenyl borate as additive and tris-2-ethyl-hexyl phosphate (TOP) as plasticizer solvent was prepared. The electrode shows a good Nernestian response over the concentration range of 0.09–5586 µ...
full textA Hybrid Model of Heart Anomalies Detection by Processing Heart Sounds
Introduction: Different factors are effective in detecting heart abnormalities. The greater the number of these factors, the greater the uncertainty in the detection of heart abnormalities. In the uncertainty condition in response of prediction model, the fuzzy systems are one of the most effective methods for generating an acceptable response. Method: In this applied study, 3240 records rela...
full textMy Resources
Journal title
volume 16 issue None
pages 340- 349
publication date 2013-01
By following a journal you will be notified via email when a new issue of this journal is published.
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023