نتایج کاربرد بالون پمپ داخل آئورت در بیماران جراحی قلبIntra-Aortic Ballon Pump Outcome in Cardiac Surgical Patients
Authors
Abstract:
Background & Aim: Intra-aortic ballon pump(IABP) is a mechanical device that has become an accepted treatment modality for patients with severely compromised hemodynamics. The present retrospective study was undertaken to identify the major survival and nonsurvival determinants of patients who were in need of intra-aortic ballon pump support after cardiac surgery. Patients & Methods: This study was conducted on 46 out of 2200 patients who underwent coronary artery bypass grafting(CABG) during one year in Tehran Shahid Rajaie Hospital and required IABP support. The patients were divided into survival(n=33) and nonsurvival(n=13) groups. Nonsurvival group was divided into 2 subgroups weaned and not weaned from IABP. Variables compared between 2 groups were: sex, age, body surface, smoking, acute myocardial infarction(AMI), diabetes mellitus, previous cardiac surgery, ejection fraction(EF), functional class according to Canadian Cardiovascular Society(CCS), duration of cardiopulmonary bypass(CPB), aortic occlusion, IABP support, mechanical ventilation and intensive care unit(ICU) stay. Differences between 2 groups were analysed via student’s t-test, chi-square test, and frequency analysis. A Pvalue of <0.05 was regarded a significant level. Results: Overall survival and nonsurvival rate was 71.17% and 28.3% respectively. Nonsurvival group had higher rate of Canadian Cardiovascular Society functional class III, IV(P=0.03) and depressed left ventricular ejection fraction(P=0.13). This group had longer duration of cardiopulmonary bypass(P=0.01) and aortic occlusion(P=0.02). No significant difference was seen with other variables. In nonsurvival group, 6 patients weaned and 7 patients were not weaned from IABP, but all died from heart failure(P=0.009), renal failure(P=0.059), or respiratory failure(P=0.3). Conclusion: This data suggest that heart failure was the major cause of death in patients not weaned from IABP, and patients with EF<30% had a poorer outcome. In patients weaned from IABP, renal failure, heart failure and respiratory failure were causes of death.
similar resources
نتایج کاربرد بالون پمپ داخل آئورت در بیماران جراحی قلبintra-aortic ballon pump outcome in cardiac surgical patients
زمینه و هدف: بالون پمپ داخل آئورت(intra aortic ballon pump=iabp) یک دستگاه مکانیکی است که جهت کمک به حفظ جریان خون سیستمیک مورد استفاده قرار می گیرد و یک درمان پذیرفته شده در بیمارانی که علایم همودینامیک آن ها چه قبل و چه بعد از عمل جراحی شدیداً تحت مخاطره قرار گرفته، محسوب می شود. این مطالعه جهت بررسی عوامل تعیین کننده زنده ماندن یا زنده نماندن بیمارانی که بعد از جراحی قلب به بالون پمپ نیاز دار...
full textThe Evaluation of Survival in Patients Who Need Intra Aortic Balloon Pump (IABP) after Cardiac Surgery
Introduction: Insome cases, assist devices are required to ensure an adequate cardiac output after cardiac surgery. Intra-aortic balloon pump (IABP) is the most commonly used cardiac assist device, which provides first-line support for patients with heart failure. The aim of this study was to determine factors affecting the mortality rate of patients receiving IABP. Materials & Methods: In thi...
full textبررسی نتایج جراحی دایسکشن آئورت تیپ A در بیماران
Background and purpose: Type A acute aortic dissection is a serious life-threatening condition that requires emergency surgery. Development of complications and operative management may be affected by various factors. The aim of this study was to evaluate the risk factors and outcomes after surgical treatment of acute type A dissection. Materials and methods: A Cross-sectional descriptive st...
full textنتایج استفاده از بالون داخل آئورتی در اعمال جراحی قلب و عوامل موثر بر موفقیت آن
سابقه و هدف: استفاده از دستگاه های کمکی قلب، بالون داخل آئورتی (IABP) به عنوان یک روش موثر در درمان بیماران دچار نارسایی قلبی پیشرفته در کنار درمان های جراحی و فارماکولوژیک، ذکر شده و هم اکنون هم به طور گسترده ای در کشورمان مورد استفاده قرار می گیرد. در مورد چگونگی، انجام نتایج و عوامل موثر بر آن هنوز در ادبیات پزشکی و به خصوص در ایران به علت فقدان مطالعه علمی و سیستماتیک در این مورد توافق نظر ...
full textبررسی نتایج حاصل از بالون پمپ داخل آئورتی در بیماران بابرون ده قلبی پایین پس از اعمال جراحی قلب از سال 1373 تا پایان پاییز 1378 در کرمانشاه
بالون پمپ داخل آئورتی، در بیمارانی که دچار شوک کاردیوژنیک متعاقب عمل جراحی قلب می شوند، مناسبترین درمان تهاجمی اولیه بشمار می رود. iabp، یک وسیله کمکی است که برون ده قلبی را افزایش می دهد و این کار را با کاهش afterload متعاقب کاهش فشار پایان دیاستولیک و حجم پایان دیاستولیک و افزایش فشار perfusion کرونر متعاقب افزایش فشار دیاستولیک انجام می دهد. بنابراین عمل قلب، بوسیله دو مکانیسم اف...
15 صفحه اولمقایسه نتایج درمانی بالون والوپلاستی و والوتومی جراحی در بیماران مبتلا به تنگی مادرزادی دریچه آئورت در پیگیری 6 ساله در بخش کودکان بیمارستان قلب شهید رجایی تهران
Background: Balloon valvuloplasty is a relatively new technique for relief of obstruction of aortic valve. The primary results of this procedure are similar to surgical valvotomy with fewer complications and mortality. Materials and methods: One hundred fifty-five patients with congenital aortic stenosis were enrolled in this study over a period of 6 years (1991-1997). Participants were all un...
full textMy Resources
Journal title
volume 12 issue 48
pages 55- 61
publication date 2005-09
By following a journal you will be notified via email when a new issue of this journal is published.
No Keywords
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023