فراوانی لژیونلا پنوموفیلا در شیر آب سرد و گرم و مخزن آب انکوباتورهای بخش نوزادان بیمارستانهای گیلان
Authors
Abstract:
Background and purpose: Nosocomial outbreaks of legionnaires’ diseases are usually related to contamination of water sources. This survey investigated the frequency of mip gene in cold and warm water taps and water containers of infant incubators containing legionella pneumophila in hospitals of Guilan province, Iran. Materials and methods: This cross-sectional study used 140 samples. They were collected directly from sterile containers and were concentrated by centrifuge, then transferred to buffered charcoal yeast extract including both L-cyctein, Fe2+ ,glycin, and vancomycin and were incubated for 2-4 days. DNA was extracted using boiling method and PCR was performed to investigate legionella, mip gene and bacterial contamination using different primers. Results: About 8.5% of the samples contained legionella pneumophila that 11.1% were isolated from infant incubators and 5.8% were found in hot and cold tap waters. Mip gene was found in 2.8% of the samples. One third of incubator’s legionella pneumophila and half of the legionella pneumophila in hot water taps contained mip gene while the samples from cold taps were not found with mip gene. About 87.2% of negative samples showed bacterial contamination. Conclusion: Today sterile water is used in incubators, however, legionella and bacterial contaminations are considerably high. This may be due to long-term storage of water in incubator container that is a predisposing factor for biofilm formation. In this study high temperature of hot water system and high rate of free residual chlorine in tap water system were the main causes of low rate legionella contamination which did not influence the contamination rate with other bacteria.
similar resources
کاربرد فرآیند ازن زنی در حذف لژیونلا پنوموفیلا از آب
زمینه: ابتلا و مرگ و میر ناشی از لژیونلا پنوموفیلا یک مشکل بهداشتی در سراسر جهان است. با توجه به نقش آب در انتقال لژیونلا روش های مختلفی برای گندزدایی آب استفاده شده است. هدف مطالعه بررسی کارایی فرآیند ازن زنی و تأثیر تراکم باکتریایی، زمان تماس و ph در حذف لژیونلا پنوموفیلا از آب بود. روش ها: لژیونلا پنوموفیلا جداشده از آب بیمارستان با تراکم 300، 700 و cfu/ml1000 به آب شهری استریل شده اضافه گرد...
full textبررسی میزان آلودگی منابع آبی بیمارستانهای شهرخرم آباد به باکتری لژیونلا پنوموفیلا در سال 1387
Background: Legionella is a negative aquatic bacterium and one of the most common nosocomial pathogen. Hospital environment in case of growth, aerosol transmission system and endangered individuals are the high potential location for growth and prevalence of this agent. The suitable temperature in water reservoirs and water distribution system empowered the growth of this bactria. The purpose...
full textمقایسه تأثیر وضعیت طاق باز و دمر بر وضعیت تنفسی نوزادان نارس مبتلا به سندرم دیسترس تنفسی حاد تحت درمان با پروتکل Insure
کچ ی هد پ ی ش مز ی هن ه و فد : ساسا د مردنس رد نامرد ي سفنت سرتس ي ظنت نادازون داح ي سکا لدابت م ي و نژ د ي سکا ي د هدوب نبرک تسا طسوت هک کبس اـه ي ناـمرد ي فلتخم ي هلمجزا لکتورپ INSURE ماجنا م ي دوش ا اذل . ي هعلاطم ن فدهاب اقم ي هس عضو ي ت اه ي ندب ي عضو رب رمد و زاب قاط ي سفنت ت ي هـب لاتـبم سراـن نادازون ردنس د م ي سفنت سرتس ي لکتورپ اب نامرد تحت داح INSURE ماجنا درگ ...
full textفراوانی آلودگی آب مصرفی بیمارستانهای تهران با لژیونلا
زمینه: لژیونلا میکروارگانیسم آبزی همه جایی است که توانایی بقاء در آب با درجه حرارت های مختلف را دارد. از 49 گونه شناسایی شده، 20 گونه باعث عفونت در انسان می شوند.آلودگی با لژیونلا در سیستم های توزیع آب بیمارستان ها دارای اهمیت می باشد. سیستمهای تولید کننده آئروسل مانند لوله کشی آب، سردوش های حمام، برج های خنک کننده و نبولایزرها در انتقال این باکتری به بیماران بستری و دارای ضعف ایمنی نقش دارند....
full textبررسی حضور باکتری لژیونلا پنوموفیلا و عوامل محیطی مؤثر بر رشد آن در سیستم آبرسانیبیمارستان آیت ا... طالقانی
سابقه و هدف:باکتری لژیونلا پنوموفیلا یکی از عوامل شایع بروز عفونتهای بیمارستانی است. این باکتری فلور آب بوده و توانایی بقا در آبهایی با درجه حرارت و pH مختلف، مواد مغذی و اکسیژن را دارد؛ سیستمهای آب گرم نیز محیطی ایدهآل برای رشد این باکتری را فراهم میکنند. هدف از این مطالعه شناسایی لژیونلا پنوموفیلا و عوامل مؤثر بر رشد آن در سیستمهای آب بیمارستان طالقانی است. مواد و روشها:در این تحقیق توصیف...
full textMy Resources
Journal title
volume 23 issue 98
pages 312- 321
publication date 2013-03
By following a journal you will be notified via email when a new issue of this journal is published.
No Keywords
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023