دزیمتری in-vivo در پرتودرمانی خارجی تومورهای مغزی تحت درمان با فوتون MV15 با استفاده از فیلم گاف کرومیک EBT3
Authors
Abstract:
Background and purpose: In-vivo dosimetry is used to ensure accurate delivery of dose to tumors during radiotherapy. This study aimed at measuring the entrance doses without the build-up cap for patients undergoing 15MV radiotherapy and determining the percentage errors between doses measured by films and those calculated with a treatment planning system (TPS). Materials and methods: The study was performed on 30 patients with brain tumor undergoing radiotherapy by 15MV photons of a Siemens linac. A novel method was developed for in-vivo dosimetry, without the need to use build-up caps and was used to estimate conversion coeficients in a solid water phantom for various irradiation conditions with and without a 30º wedge for 5×5, 10×10, and 15×15cm2 field sizes and 80, 90 and 100cm SSDs. The conversion coeficients provided ratios of surface doses measured by gafchromic films to those of an ioniztion chamber for various conditions. Results: For 4 patients, more than 5% error was noted in in-vivo doses. The mean and standard deviation of errors between the doses measured and those calculated with TPS for the patients’ skulls were -2.23% and 3.36%, respectively. The conversion coefficients increased by increase in field size and decrease of SSD. The conversion coefficients for all irradiation conditions were greater for the fields with the wedge than those without it. Conclusion: The novel dosimetry method developed for measuring the entrance dose without any need to use build-up caps usual in conventional dosimetry methods, not only makes no disruption in the dose reached to patient’s treatment volume, but also provides an accurate estimation of entrance dose in clinical situations.
similar resources
پیشنهاد یک پروتکل ساده برای دزیمتری in vivo در پرتودرمانی تومورهای سر و گردن با استفاده از تصویربرداری پورتال
زمینه و هدف : لزوم وجود برنامههای دورهای کنترل کیفیت در آنکولوژی تابشی توسط سازمانهای مختلفی نظیر AAPM ، ACR ، ACMP و ESTRO توصیه شده است. یکی از بهترین روشهای انجام کنترل کیفیت انجام دزیمتری in vivo در حین پرتودرمانی میباشد. این مطالعه به منظور طراحی پروتکلی ساده برای دزیمتری in vivo در پرتودرمانی تومورهای سر و گردن با استفاده از تصویربرداری پورتال انجام گردید. روش بررسی : در این مطالعه ...
full textمقایسه تأثیر وضعیت طاق باز و دمر بر وضعیت تنفسی نوزادان نارس مبتلا به سندرم دیسترس تنفسی حاد تحت درمان با پروتکل Insure
کچ ی هد پ ی ش مز ی هن ه و فد : ساسا د مردنس رد نامرد ي سفنت سرتس ي ظنت نادازون داح ي سکا لدابت م ي و نژ د ي سکا ي د هدوب نبرک تسا طسوت هک کبس اـه ي ناـمرد ي فلتخم ي هلمجزا لکتورپ INSURE ماجنا م ي دوش ا اذل . ي هعلاطم ن فدهاب اقم ي هس عضو ي ت اه ي ندب ي عضو رب رمد و زاب قاط ي سفنت ت ي هـب لاتـبم سراـن نادازون ردنس د م ي سفنت سرتس ي لکتورپ اب نامرد تحت داح INSURE ماجنا درگ ...
full textاثر بربرین در تنظیم آستروسیتهای Gfap+ ناحیه هیپوکمپ موشهای صحرایی دیابتی شده با استرپتوزوتوسین
Background: Diabetes mellitus increases the risk of central nervous system (CNS) disorders such as stroke, seizures, dementia, and cognitive impairment. Berberine, a natural isoquinolne alkaloid, is reported to exhibit beneficial effect in various neurodegenerative and neuropsychiatric disorders. Moreover astrocytes are proving critical for normal CNS function, and alterations in their activity...
full textاثر بربرین در تنظیم آستروسیتهای Gfap+ ناحیه هیپوکمپ موشهای صحرایی دیابتی شده با استرپتوزوتوسین
Background: Diabetes mellitus increases the risk of central nervous system (CNS) disorders such as stroke, seizures, dementia, and cognitive impairment. Berberine, a natural isoquinolne alkaloid, is reported to exhibit beneficial effect in various neurodegenerative and neuropsychiatric disorders. Moreover astrocytes are proving critical for normal CNS function, and alterations in their activity...
full textتعیین منحنی کالیبراسیون و ارزیابی دقیق میزان خطا و عدم قطعیت در دزیمتری با فیلم گاف کرومیک EBT2
در پرتودرمانی، میزان دز داده شده به بافت هدف باید صحت بالایی داشته باشد، و عدم دقت در آن میتواند روی نتیجهی درمان اثر بگذارد. با پیدایش فیلمهای جدید رادیوکرومیک، دزیمتری با فیلم به ابزاری قدرتمند برای تأیید و تضمین کیفیت پرتودرمانی بدل شده است. فیلمهای گافکرومیک EBT2 به دلیل داشتن ویژگیهایی مانند محدودهی حساسیت گسترده، قدرت تفکیک مکانی بالا و شرایط بازخوانی و حمل آسان، از جدیدترین و ...
full textپیشنهاد یک پروتکل ساده برای دزیمتری in vivo در پرتودرمانی تومورهای سر و گردن با استفاده از تصویربرداری پورتال
زمینه و هدف : لزوم وجود برنامه های دوره ای کنترل کیفیت در آنکولوژی تابشی توسط سازمان های مختلفی نظیر aapm ، acr ، acmp و estro توصیه شده است. یکی از بهترین روش های انجام کنترل کیفیت انجام دزیمتری in vivo در حین پرتودرمانی می باشد. این مطالعه به منظور طراحی پروتکلی ساده برای دزیمتری in vivo در پرتودرمانی تومورهای سر و گردن با استفاده از تصویربرداری پورتال انجام گردید. روش بررسی : در این مطالعه c...