تأثیر توزیع یکنواخت و غیریکنواخت نانوذرات با اعداد اتمی بالا در حجم تومور بر فاکتور افزایش دوز در براکی تراپی با چشمه ایریدیم-192
Authors
Abstract:
Introduction: Irradiation of loaded tumor with high-Z nanoparticles with low energy photon of 192Ir source during brachytherapy increases absorbed dose of tumor due to increase in possibility of photoelectric phenomena. Therefore, this study aimed to investigate dose enhancement due to nanoparticles (NPs) with different atomic numbers and concentrations as well as effect of NPs distribution (uniform & non- uniform) on dose enhancement. Methods: Dosimetric parameters of HDR-192Ir source (MicroSelectron model) were calculated by MCNP-4C code on the basis of recommendations of AAPM, TG-43. A tumor (1 cm3) loaded with uniform and non-uniform distribution of 7, 18 and 30 mgr/gr of 79Au, 64Gd, 26Fe and 22Ti in water phantom (30×30×30 cm3) was simulated. Results: DEF of 4.7% to 19.4% and 3.3 to 18.6% were calculated respectively for uniform distribution of 79Au and 64Gd with 7 to 30 mgr/gr concentrations. For non-uniform distribution these values were 0.4%to 1.9% and 0.2% to 1.2%, respectively. Increased dose of the peripheral-health tissue due to presence of 2 to 8.5 mgr/gr of 79Au and 64Gd was estimated from 1.3% to 6.5% and 1.1% to 4.2%, respectively. Conclusion: increase of atomic number and concentrations of NPs enhance the absorbed dose due to increased possibility of photoelectric phenomena. Non-uniform distribution of NPs underestimated dose compared to uniform distribution therefore, considering accurate NPs distribution inside the tumor volume is crucial to calculation of dose enhancement. Targeted labeling of NPs for the maximum absorption by tumor and for the minimal penetration into peripheral tissues has potential to increase radiation therapeutic ratio.
similar resources
تأثیر توزیع یکنواخت و غیریکنواخت نانوذرات با اعداد اتمی بالا در حجم تومور بر فاکتور افزایش دوز در براکی تراپی با چشمه ایریدیم-۱۹۲
مقدمه: پرتودهی تومور پر شده با نانوذرات با اعداد اتمی بالا به وسیله فوتون های کم انرژی چشمه ایریدیوم-192 در براکی تراپی، دوز تومور را به دلیل افزایش احتمال رخداد پدیده فوتوالکتریک افزایش خواهد داد. هدف از این مطالعه، بررسی افزایش دوز ناشی از نانوذرات با اعداد اتمی و با غلظت های مختلف و بررسی اثر توزیع نانوذرات (یکنواخت و غیریکنواخت) بر افزایش دوز بود. روش بررسی: پارامترهای دزیمتری چشمه ایریدیوم...
full textاثر بربرین در تنظیم آستروسیتهای Gfap+ ناحیه هیپوکمپ موشهای صحرایی دیابتی شده با استرپتوزوتوسین
Background: Diabetes mellitus increases the risk of central nervous system (CNS) disorders such as stroke, seizures, dementia, and cognitive impairment. Berberine, a natural isoquinolne alkaloid, is reported to exhibit beneficial effect in various neurodegenerative and neuropsychiatric disorders. Moreover astrocytes are proving critical for normal CNS function, and alterations in their activity...
full textاثر بربرین در تنظیم آستروسیتهای Gfap+ ناحیه هیپوکمپ موشهای صحرایی دیابتی شده با استرپتوزوتوسین
Background: Diabetes mellitus increases the risk of central nervous system (CNS) disorders such as stroke, seizures, dementia, and cognitive impairment. Berberine, a natural isoquinolne alkaloid, is reported to exhibit beneficial effect in various neurodegenerative and neuropsychiatric disorders. Moreover astrocytes are proving critical for normal CNS function, and alterations in their activity...
full textافزایش دوز ناشی از تزریق نانوذرات طلا، گادلینیوم، آهن و تیتانیوم به تومورهای سرطانی در براکیتراپی با چشمه ایریدیم- 192: روش مونتکارلو
زمینه و هدف: در برهمکنشهای فوتون با ماده، افزایش عدد اتمی ماده هدف و کاهش انرژی فوتون تابشی جذب فوتوالکتریک را در آن ماده افزایش میدهد. در مطالعة حاضر فاکتور افزایش دوز (Dose Enhancmenet Factor) تومور پر شده با نانوذرات (Nano Particles) برای براکیتراپی با چشمه ایریدیم- 192 مطالعه شد. روش بررسی: محاسبات مونتکارلو برای تعیین افزایش دوز ناشی از چشمه ایری...
full textبررسی اثر ناهمگنیهای بافت بر توزیع دوزچشمه ایریدیم-192 در براکی تراپی
زمینه و هدف: اشکال پروتکل انجمن فیزیک پزشکی آمریکا (AAPM, TG43) برای دزیمتری براکیتراپی این است که اثر وجود ناهمگنیهای بافتی (استخوان، ریه، ...) بر توزیع دوز بههنگام بهکارگیری پارامترهای دزیمتری حاصله در نرمافزارهای طراحی درمان در نظر گرفته نمیشود. هدف از این تحقیق بررسی اختلافات دوز با و بدون وجود این ناهمگنیها در براکیتراپی با چشمه ایریدیم-192 است. روش ...
full textبررسی فاکتور افزایش دوز تومور با حضور نانو ذرات مختلف در براکی-تراپی پروستات بهروش مونت کارلو
زمینه و هدف: یکی از راههای درمان پروستات، استفاده از چشمههای براکیتراپی کمانرژی مانند ید-125 است. هدف ما دراین مطالعه، بررسی فاکتور افزایش دوز تومور با حضور نانو ذرات مختلف در براکیتراپی پروستات بهروش مونت کارلو و بررسی اثر حضور نانو ذرات بر منحنیهای هم دوز در براکیتراپی پروستات میباشد. مواد و روشها: در این مطالعه، چشمهی براکیتراپی ید-125 مدل SL-125/SH-125 با استفاده از کدMCNPX م...
full textMy Resources
Journal title
volume 21 issue 5
pages 587- 598
publication date 2013-12
By following a journal you will be notified via email when a new issue of this journal is published.
No Keywords
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023