بی حسی نخاعی برای عمل جراحی سزارین: مقایسه بوپی واکا یین هیپرباریک با ایزوباریک

Authors

Abstract:

Aims and Background: The baricity of the solutions used for spinal anesthesia significantly affects the distribution and dissemination of local anesthetics into the spinal space. The purpose of this study was to compare the effects of hyperbaric and isobaric bupivacaine for spinal anesthesia in cesarean section. Materials and Methods: This was a randomized double blind clinical trial on sixty patients (18-40 years old) with ASA I-II, who were candidate for elective cesarean section. Spinal anesthesia was applied by isobaric bupivacaine in the first group and hyperbaric bupivacaine in the second group. The data including hemodynamic parameters of the patients, oxygen saturation level, sensory and motor block levels, and consumption of ephedrine and complications of spinal anesthesia were all recorded. Statistical analysis by using SPSS software was applied using T-test, Chi-square test, and repeated ANOVA. P values<0.05 were considered significant. Findings: Patients in both groups were almost similar regarding demographic values and the duration of surgery. Among the other recorded variables only the duration of analgesia and the frequency of nausea and vomiting was considerably higherin the isobaric group compared with the hyperbaric one (P<0.001 , P= 0.001 respectively). There was no significant difference between the two groups regarding the other variables. Conclusions: Isobaric bupivacaine had the same effectiveness as hyperbaric type for spinal anesthesia, and it even had a longer duration of analgesia. However the higher incidence of nausea and vomiting with isobaric type must be taken into account.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

مقایسه اثر بیهوشی عمومی و بی حسی نخاعی بر روی آپگار نوزادان در عمل جراحی سزارین

مقدمه: در انجام عمل سزارین از دو روش بیهوشی عمومی و بی حسی موضعی استفاده می شود. داروهای مورد استفاده در هر یک از این روش ها، دارای عوارض و مزایایی خاصی برای مادر و جنین می باشد. تأثیر هر کدام از این روش ها بر روی آپگار نوزادان متولد شده متفاوت است. در برخی مطالعات تفاوتی بین آپگار نوزادان گزارش نشده و در برخی، نوزادان متولد شده با بیهوشی عمومی، آپگار پایین تری داشتند. مطالعه حاضر با هدف مقایسه...

full text

مقایسه دو روش بی حسی نخاعی مدین و پارامدین جهت عمل جراحی سزارین

Aim and Background: Spinal anesthesia is a very common anesthetic technique in cesarean section. It is usually applied through the median or paramedian approach among which the median approach is more common. The purpose of this study was to compare the median with paramedian approaches in elective cesarean section operations. Methods and Materials: This double -blind randomized clinical trial ...

full text

اثر سوفنتانیل داخل نخاعی بر عوارض همودینامیک بی حسی داخل نخاعی با لیدوکائین %5 در عمل جراحی سزارین

Background and Aim: Spinal anesthesia is the preferred method for cesarian section -because of minimal maternal and neonatal complications and low cost. Intrathecal sufentanil is used for augmentation of analgesic effect in spinal anesthesia. The aim of this study was to evaluate the effect of intrathecal sufentanil on hemodynamic measurements and other complications. Materials and Methods: Th...

full text

مقایسه دو روش بی حسی نخاعی مدین و پارامدین جهت عمل جراحی سزارین

زمینه و هدف: ب یحسی نخاعی یکی از شای عترین تکنی کهای ب یحسی برای عمل سزارین است و معمولاً با دو روش مدین و پارامدین انجام م یشود که روش مدین شای عتر است. هدف این مطالعه مقایسه متغیی رهای کلی دو روش ب یحسی داخل نخاعی حین عمل جراحی سزارین الکتیو بود. مواد و رو شها: این کارآزمایی بالینی دو سو کور بر روی 150 زن باردار 15 - 45 ساله انجام شد. بیماران ب هصورت تصادفی به گروه ب یحسی نخاعی با روش مدین یا ...

full text

مقایسه اثر بیهوشی عمومی و بی حسی نخاعی بر روی آپگار نوزادان در عمل جراحی سزارین

مقدمه: در انجام عمل سزارین از دو روش بیهوشی عمومی و بی حسی موضعی استفاده می شود. داروهای مورد استفاده در هر یک از این روش ها، دارای عوارض و مزایایی خاصی برای مادر و جنین می باشد. تأثیر هر کدام از این روش ها بر روی آپگار نوزادان متولد شده متفاوت است. در برخی مطالعات تفاوتی بین آپگار نوزادان گزارش نشده و در برخی، نوزادان متولد شده با بیهوشی عمومی، آپگار پایین تری داشتند. مطالعه حاضر با هدف مقایسه...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 7  issue 4

pages  44- 53

publication date 2017-01

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

No Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023