بررسی اثر فرایند گرمایی و باریکه الکترونی پرانرژی (10 MeV) بر بلورشدگی پلی اتیلن

Authors

  • میرجلیلی, غضنفر دانشگاه یزد
  • برهانی زرندی, محمود دانشگاه شهید باهنر کرمان
  • بلوری زاده, محمد آقا دانشگاه شهید باهنر کرمان
  • ضیائی, فرهود پژوهشکده مواد، مجتمع پژوهشی کرج، پژوهشکده علوم و فنون هسته ای سازمان انرژی اتمی ایران
Abstract:

Samples from two type of polyethylene, with low and high density, had been subjected to three different initial processing. The samples were heated to 170 oC and then cooled by different cooling rating in air, in mold (10 oC/min cooling rate) and in 0.0 oC water. Following this step, each sample irradiated by 10 MeV electron beam. The gel content of the samples, which is a measure of interchain cross links formed on the amorphous area of the polymer, is a created due to electron impaction and was extracted into the xylene. Change in crystallinity of the samples was monitored by differential scanning calorimetry (DSC) technique. It has been shown that increase of the radiation dose up to 200 KGy, increases to the gel content of the polymer samples, but in higher doses remains without considerable change. Crystallinity of the polymer samples depends on the heat treatment and also radiation dose. Cooling rate has significant effect on crystallinity, so the more cooling rate the crystalline content of the polymer more reduces. However, Cystallinity of the polymer samples due to the absorption of  radiation up to 200 KGy increases and then with increase of radiation dose decreases. Our study showed that change in crystallinity of the LDPE due to the absorption of the radiation is more than that of HDPE.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

بررسی فرایند سردشدن پلی‌پروپیلن گداخته، و اثر تابش پرتو الکترونی پر انرژی (MeV 10) بر تغییر بلورینگی آن

In this research, the effects of cooling rate and high energy electron beam irradiation on the change of crystallinity of polypropylene was investigated. For this work, samples of polypropylene heated to 230 ºC and then rapidly cooled with different speed of cooling. Crystalliny of samples were determined by differential scanning calorimetry and infrared spectroscopy. It was shown that percenta...

full text

مطالعه اثر باریکه الکترونی بر کیفیت شیمیایی گوشت شترمرغ

سابقه و هدف : گوشت شترمرغ یکی از کم­چرب­ترین و سالم‌ترین نمونه‌های گوشت قرمز در دسترس است . پرتودهی از استراتژی‌های مداخله‌گر به‌منظور کاهش میکروارگانیسم‌های پاتوژن منتقله از غذا می‌باشد. در این مطالعه کیفیت شیمیایی گوشت شترمرغ پس از پرتودهی باریکه الکترونی موردبررسی قرار گرفت.  مواد و روش­ ها: در این مطالعه نمونه‌های گوشت شترمرغ با باریکه الکترونی به میزان 1/5، 3 و 5 کیلوگری مورد تیمار قرارگرف...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 16  issue 1

pages  131- 140

publication date 2008-04

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

No Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023