بررسی اثر بازدارندگی آنتی بیوتیک مترونیدازول قبل و بعد از فرایند اکسیداسیون پیشرفته UV254/H2O2بر فعالیت متانسازی ویژه بیومس بیهوازی
Authors
Abstract:
Background & Objectives: Disposal of pharmaceutical compounds to environment as an emerging pollutants cause concerns significantly and it is necessary to use new methods of sewage treatment for removal of these compounds. The aim of this study was to investigate the inhibition effects of metronidazole before and after using UV254/H2O2 process on specific methanogenic activity of.anaerobic biomass. Materials & Methods: Fourteen anaerobic digestion tests were carried out at batch scale before and after using UV254/H2O2 process in 500 ml reactors with 30% anaerobic biomass and 70% substrate. The liquid displacement method was used. Duration of each test was in the range of 10-17 days. Results: Cumulative Biomethane production in concentrations of 1, 5, 10, 25, 50, and 100 mg/l metronidazole was 34.04, 95.12, 100.86, 3.28, 27.88, and 6.97 ml respectively. This production was 800.73, 243.54, and 10.66 ml in concentrations of 25, 50, and 80 mg/l respectively using UV254/H2O2 process as pretreatment at 60 min retention time. Biomethane production in concentrations of 80,120, and 150 mg/l was 377.2, 380.48, and 63.14 ml respectively at 90 min retention time. Conclusion: Different concentrations of metronidazole had an inhibition effect on anaerobic digestions and therefore the efficient pretreatment method is needed to reduce this inhibition effect. The UV254/H2O2 process is an effective method for degradation and conversion of metronidazole to more biodegradable compounds for anaerobic bacteria consumption and, in turn, to increase biogasproduction in anaerobic digestions.
similar resources
بررسی اثر بازدارندگی آنتی بیوتیک مترونیدازول قبل و بعد از فرایند اکسیداسیون پیشرفته uv۲۵۴/h۲o۲بر فعالیت متان سازی ویژه بیومس بیهوازی
زمینه و هدف: دفع ترکیبات داروئی به محیط زیست به عنوان آلاینده های نو ظهور، نگرانی قابل توجهی ایجاد کرده و استفاده از روش های جدید تصفیه فاضلاب جهت حذف این ترکیبات ضروری بنظر می رسد. مطالعه حاضر درصدد بررسی میزان تاثیر بازدارندگی داروی مترونیدازول قبل و بعد از تصفیه با استفاده از فرایند uv254/h2o2 بر فعالیت متان سازی ویژه جرم زیستی بی هوازی است. روش بررسی: تعداد 14 آزمایش هضم بی هوازی به روش ناپ...
full textبررسی کارایی فرایند اکسیداسیون پیشرفته اولتراسونیک/تابش فرابنفش/پراکسیدهیدروژن در حذف آنتی بیوتیک تتراسایکلین از محلول های آبی
زمینه و هدف: از میان انواع مختلف آنتی بیوتیک ها، تتراسایکلین ها دومین گروه شایع آنتی بیوتیک ها از نظر تولید و مصرف در سراسر جهان هستند که ورود آنها به فاضلاب خانگی می تواند منجر به آلودگی منابع آب شود. هدف از انجام این مطالعه تعیین کارایی فرایند US/UV/H2O2 در حذف آنتی بیوتیک تتراسایکلین از محلول های آبی می باشد. مواد و روش کار: پژوهش حاضر یک مطالعه تجربی بوده که با استفاده از حمام اولتراسونیک و...
full textبررسی کارایی فرایند اکسیداسیون پیشرفته بر پایه پرسولفات (UV/Na2S2O8) برای حذف مترونیدازول از محلولهای آبی
Background and purpose: Antibiotics are extensively used in treatment of diseases. Metronidazole is an antimicrobial agent and is a nitroimidazole derivative, which is widely used in treatment of infectious diseases caused by bacteria and protozoa. This compound is irrefrangible, toxic, carcinogenic, mutagenic, and has high solubility in water. Advanced oxidation process is an effective method ...
full textبررسی راندمان حذف آنتی بیوتیک مترونیدازول از محلول های آبی با استفاده از فرایند ازن زنی
Background and purpose: Antibiotics have worldwide uses and they can enter water sources through different ways. Due to their different inappropriate effects, they have created a major concern in environmental control practices. Metronidazole (MTN) is an example of these antibiotics. This study was performed to investigate the efficiency of ozonation process (SOP) in MTN removal from aqueous ...
full textفرایند ترکیبی انعقاد و اکسیداسیون پیشرفته با فنتون در حذفcod آنتی بیوتیک کلاریترومایسین
آنتی بیوتیک ها جزء آلاینده های مهم محیط های آبی به حساب می آیند. در این مطالعه حذف آنتی بیوتیک کلاریترومایسن از فاضلاب ساختگی از طریق فرایند تلفیقی انعقاد و اکسیداسیون پیشرفته مورد بررسی قرار گرفت. این تحقیق در مقیاس آزمایشگاهی و به صورت ناپیوسته انجام شد. فاضلاب ساختگی از آنتی بیوتیک کلاریترومایسین با غلظت 200 میلی گرم در لیتر ساخته شد. شاخص cod به عنوان پارامتر مورد بررسی انتخاب گردید. ابتدا ...
full textبررسی کارائی فرایند ترکیبی انعقاد و اکسیداسیون پیشرفته شبه فنتون در حذفcod فاضلاب سنتتیک آنتی بیوتیک کلاریترومایسین از فاضلاب
آنتی بیوتیک ها جزو آلاینده های مهم محیط های آبی به حساب می آیند.در این مطالعه حذفcod آنتی بیوتیک کلاریترومایسن از فاضلاب سنتتیک ازطریق فرایند ترکیبی انعقاد و اکسیداسیون پیشرفته با شبه فنتون مورد بررسی قرار گرفته است مواد و روش ها: این تحقیق در مقیاس آزمایشگاهی و به صورت ناپیوسته انجام گرفت. فاضلاب سنتتیک از آنتی بیوتیک کلاریترو مایسین با غلظت 200 میلی گرم بر لیتر ساخته شد. شاخصcod به عنوان پارا...