بررسی اثر استریلیزاسیون خشک و مرطوب بر سایش لیگاچرکاترهای ارتودنتیک

Authors

  • اسلامی, بهنام
  • اسلامیان, لادن
  • لطفعلیان, مرضیه
Abstract:

Background and Aim: Orthodontic ligature cutting pliers are expensive. Methods of sterilization should be safe considering patients' health as well as lifetime of orthodontic pliers. The purpose of this study was to compare the wear of orthodontic ligature cutting pliers after sterilizing with dry heat or steam autoclave. Materials and Methods: In this experimental study, thirty ligature cutting pliers from 3 different factories (Dentarum-Germany, RMO and ETM-USA) were sterilized in either dry heat or steam autoclave. The amount of wear at the tip of each plier in both groups was measured with a stereomicroscope and digital photomicrography. Wear was defined as the difference of the initial length and the length after 10, 20, 30 cycles of sterilization measured by the distance from a reference line on the tip of the plier. Three way ANOVA was used to compare wear between the two sterilization groups. P<0.05 was considered as the limit of significance. Results: The amount of wear of the ligature cutting pliers' tip after 10, 20 and 30 cycles in dry heat sterilization was 1.0±0.16, 0.98±0.22 and 0.94±0.31 mm respectively. These figures were 1.16±0.15, 1.16±0.13 and 1.15±0.14mm for steam heat sterilization. The higest wear was observed after 20 cycles of sterilization in autoclavce whereas the lowest was seen in dry heat sterilization after 30 cycles. The differences between the two studied groups were statistically significant (P<0.0001). In addition, increasing sterilization cycles decreased the rate of wear in both groups. Conclusion: Based on the results of this study routine autoclaving caused more damage and wear at the tip of the pliers than dry heat sterilization.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

مقایسه تأثیر پانسمان خشک و مرطوب بر بهبودی زخم سوختگی

  Background & Aims: Consistent with recent scientific advances in wound treatment , modern dressing, using technology and knowledge were designed and produced . Such a dressing can provide an appropriate environment for moisturizing wound healing by maintaining and controlling moisture along with other conditions. This study aims to compare the effect of dry and moist dressing on burn wound he...

full text

مقایسه تأثیر وضعیت طاق باز و دمر بر وضعیت تنفسی نوزادان نارس مبتلا به سندرم دیسترس تنفسی حاد تحت درمان با پروتکل Insure

کچ ی هد پ ی ش مز ی هن ه و فد : ساسا د مردنس رد نامرد ي سفنت سرتس ي ظنت نادازون داح ي سکا لدابت م ي و نژ د ي سکا ي د هدوب نبرک تسا طسوت هک کبس اـه ي ناـمرد ي فلتخم ي هلمجزا لکتورپ INSURE ماجنا م ي دوش ا اذل . ي هعلاطم ن فدهاب اقم ي هس عضو ي ت اه ي ندب ي عضو رب رمد و زاب قاط ي سفنت ت ي هـب لاتـبم سراـن نادازون ردنس د م ي سفنت سرتس ي لکتورپ اب نامرد تحت داح INSURE ماجنا درگ ...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 19  issue None

pages  63- 70

publication date 2006-05

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

No Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023