استفاده از دوزهای پایین سوکسینیل کولین جهت تسهیل لوله گذاری تراشه
Authors
Abstract:
Abstract Background & Aims: Succinylcholine 1 mg/kg usually produces excellent tracheal intubation in 60 s. Recovery of respiratory muscle function after this dose, however, is not fast enough to forestall oxyhemoglobin desaturation when ventilation can not be assisted. In this study, smaller doses of succinylcholine effects were investigated for producing satisfactory intubation conditions fast enough to allow rapid-sequence tracheal intubation with shorter recovery time of respiratory function. Materials &Methods: In this prospective randomized double-blind and case-controlled clinical trial, 120 patients class I or II of American Society of Anesthesiologists (ASA), were investigated. After induction of anesthesia with fentanyl/thiopental, all patients were randomly allocated to three groups according to the dose of succinylcholine 0.3 mg/kg (1ÍED95), 0.6 mg/kg (2ÍED95), and 1 mg/kg (3ÍED95). Evoked adductor pollicicis responses to Train-of-four (TOF) in ulnar nerve stimulation were rewarded using nerve stimulator. Onset time, maximal twitch depression, tracheal intubation conditions, respiration recovery time (apnea time), and time to 90% twitch height recovery were recorded. Results: Onset times ranged between 81s and 49s, decreased with increasing doses of succinylcholine but not differing between 0.6 and 1 mg/kg. Maximum twitch depression was similar after 0.6 and 1 mg/kg (98.2%-100%). Intubation conditions were often unacceptable after 0.3 mg/kg doses, but acceptable intubations were achieved in all patients receiving a 0.6 and 1 mg/kg dose of succinylcholine. Time to respiration function recovery was significantly shorter in 0.3 and 0.6 mg/kg doses (1.8±0.6 min and 2.4±0.6 min, respectively) versus patients receiving 1 mg/kg (6.3±0.8 min p< 0.0001 v.s 0.3 mg/kg, p< 0.001 v.s 0.6 mg/kg doses respectively). Twitch recovery time to T1=90% (regular spontaneous respiration) were significantly lower in 0.6 mg/kg dose (5.2 ±1.0 min) than 1.0 mg/kg group (8.8±1.3 min p<0.001). Conclusion: The use of 0.6 mg/kg of succinylcholine can produce acceptable intubation conditions after 60 seconds of administration. The conditions achieving after 0.6 mg/kg are similar to those after 1mg/kg. These smaller doses are associated with shorter apnea time and faster twitch recovery.
similar resources
استفاده از دوزهای پایین سوکسی نیل کولین جهت تسهیل لوله گذاری تراشه
پیش زمینه و هدف: سوکسینیل کولین با دوز mg/kg 1 معمولاً شرایط عالی برای لوله گذاری تراشه در عرض60 ثانیه فراهم میکند. برگشت فونکسیون تنفسی بعد از این دوز به حد کافی سریع نیست تا از دساچوراسیون خطرناک اکسی هموگلوبین در صورت عدم امکان تهویه کمکی، جلوگیری شود. در این مطالعه، اثر دوزهای پایین تر سوکسینیل کولین برای تسهیل لوله گذاری رضایت بخش تراشه در القای سریع و متوا لی بیهوشی [1] با زمان برگشت سر...
full textبررسی مقایسه ای لوله گذاری داخل تراشه با و بدون استفاده از سوکسینیل کولین در بخش اورژانس
Background and Purpose: Succinylcholine isn’t used in Emergency Department intubations routinely, that, this study was performed to compare success and complications of tracheal intubation with and without succinylcholine administration. Materials and Methods: This interventional study was done on 150 patients admitted in Emergency Department of Hazrat Rasoul Akram Hospital who underwent ...
full textبررسی مقایسه ای استفاده از آلفانتانیل و ساکسینیل کولین در کیفیت لوله گذاری داخل تراشه
It is common to use muscle relaxants, such as succinyl choline to produce muscle relaxation during tracheal intubation. Based on some new researches alfentanyl was reported to be used without succinyl choline for tracheal intubation. The goal of this study was to evaluate the quality of tracheal intubation during general anesthesia with alfentanyl in order to see whether it can be used as a sub...
full textتاثیر پروپوفول در جلوگیری از افزایش فشار چشم بدنبال تزریق سوکسینیل کولین و لوله گذاری نای
Background and purpose: Penetrating eye injury is one of the most frequent trauma admitted in ophtalmological emergency rooms. The major concern when treating such a trauma is increased intra-ocular pressure and vitreous loss as a side effect of Succinylcholine and endotracheal intubation with no appropriate substitute drug available yet. This study is aimed to determine whether the use of...
full textبررسی مقایسه ای لوله گذاری داخل تراشه با و بدون استفاده از سوکسینیل کولین در بخش اورژانس
سابقه و هدف: با توجه به عدم استفاده روتین از داروی سوکسینیل کولین در موارد انتوباسیون یا لوله گذاری داخل تراشه (tracheal intubation) در بخش اورژانس، این مطالعه با هدف مقایسه میزان موفقیت و عوارض لوله گذاری داخل تراشه در دو روش با و بدون تزریق سوکسینیل کولین (succinyl choline) انجام گرفت.مواد و روش ها: در این مطالعه مداخله ای (interventional)، طبق روش آسان غیر احتمالی ??? فرد کاندید لوله گذاری د...
full textتاثیر دوز سوکسینیل کولین در میزان و شدت فاسیکولاسیون و دردهای عضلانی پس از عمل
زمینه و هدف: یکی از اثرات جانبی شایع سوکسینیل کولین دردهای عضلانی پس از عمل است. پاتوژنز آن نامشخص می باشد، به همین جهت روش ایده آلی برای کاهش میزان و شدت فاسیکولاسیون و دردهای عضلانی پس از تجویز سوکسینیل کولین وجود ندارد. هدف از این مطالعه آینده نگر و تصادفی، بررسی تاثیر دوز پایین سوکسینیل کولین در هنگام لوله گذاری تراشه روی میزان و شدت فاسیکولاسیون پس از تجویز آن و دردهای عضلانی پس از عمل بود...
full textMy Resources
Journal title
volume 19 issue 2
pages 106- 111
publication date 2008-10
By following a journal you will be notified via email when a new issue of this journal is published.
No Keywords
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023