ارزیابی عملکرد هودهای آزمایشگاهی براساس استاندارد ASHRAE 110 در
Authors
Abstract:
Background and Aim: Laboratory fume-hoods are the first-level protection for the laboratory staff against hazardous chemical pollutants. Considering the large numbers of personnel, especially in petrochemical industry laboratories, this project was carried out in order to assess the performance of laboratory hoods based on tracer gas (SF6).Materials and Methods: In this project 22 hoods in the laboratories of a petrochemical industry were studied. Operation of the hoods was assessed based on quantitative (with SF6 as tracer gas) and qualitative (face velocity measurement, using thermal anemometer) tests, according to ASHRAE 110 stndard.Results: In comparison with the minimum acceptable face velocity (80 fpm), the mean values of face velocities of only 9.09% of the hoods passed the test (P=0.001) and were at an acceptable level. As regards the tracer gas test, the results were even worse: only 4.5% of the hoods passed the acceptability test (p=0.001). In addition, non of the hoods having an acceptable face velocity passed the tracer gas test. Similarly, no hood with an accepatable tracer gas performance had an acceptable face velocity.Conclusion: Since there is no consistency between face velocity and tracer gas tests, performance of laboratory hoods can necessarily be assessed on the basis of the tracer gas quantitative test. The face velocity test is a supplementary test, which, if used alone wil give false results.
similar resources
ارزیابی عملکرد هودهای آزمایشگاهی براساس استاندارد ashrae ۱۱۰ در
زمینه و هدف : هودهای آزمایشگاهی اولین لایه حفاظتی برای کارکنان آزمایشگاه در برابر عوامل شیمیایی زیان آور می باشند. با توجه به کثرت شاغلین در آزمایشگاه ها بویژه در صنایع پتروشیمی ؛ این پژوهش با هدف ارزیابی عملکرد هودهای آزمایشگاهی، با استفاده از گاز ردیاب انجام گردید. تا بتوان براساس آن عملکرد هودهای آزمایشگاهی را مورد ارزیابی قرار داد. روش کار: در این پروژه عملکرد 22 عدد هود در آزمایشگاه یک شرک...
full textارزیابی عملکرد هودهای بیولوژِیکی ایمن در یک مرکز تحقیقاتی
The use of biological safety cabinets (BSCs) in laboratories has greatly increased over the last few decades. BSCs are used in laboratories to protect both the scientists and the experiments from contamination by biological hazards during tissue culture procedures. The function of BSCs depends upon the HEPA filtration, the fan performance and the airflow patterns in the cabinet. To ensure BSCs ...
full textNitrous oxide as a tracer gas in the ASHRAE 110-1995 Standard.
ANSI/ASHRAE Standard 110 provides a quantitative method for testing the performance of laboratory fume hoods. Through release of a known quantity (4.0 Lpm) of a tracer gas, and subsequent monitoring of the tracer gas concentration in the "breathing zone" of a mannequin positioned in front of the hood, this method allows for evaluation of laboratory hood performance. Standard 110 specifies sulfu...
full textارزیابی کیفی عملکرد هودهای شیمیایی آزمایشگاههای دانشگاه علوم پزشکی
Introduction: The scientific and research laboratories at universities of medical sciences use a variety of chemical and biological materials. Various people, including the laboratory staff, students, and faculty members, are exposed to these materials, and various respiratory and dermatological symptoms may occur in these people. The purpose of this study is to evaluate the use and control of ...
full textارزیابی عملکرد هودهای بیولوژِیکی ایمن در یک مرکز تحقیقاتی
استفاده از هودهای بیولوژِیکی ایمن (bscs) در سالهای اخیر گسترش روز افزونی یافته است. bscs در آزمایشگاهها برای حفاظت پژوهشگران، مواد و محصولات در برابر مخاطرات بیولوژیکی مورد استفاده قرار می گیرند. کارایی و توانایی bscs در زدودن آلودگی های میکروبی از هوا به عملکرد فیلتر هپا، فن و الگوی جریان هوا بستگی دارد. برای اطمینان از عملکرد مطلوب bscs ضروری است آن را در فواصل زمانی معین مورد آزمایش و ارزیابی...
full textارزیابی سطح عملکرد لرزهیی سازههای فولادی قاب خمشی براساس اهمیت آنها مطابق استاندارد 2800 ایران
طراحی لرزهیی در بسیاری از آییننامهها، از جمله استاندارد ۲۸۰۰ ایران، براساس روش نیرویی است. در این روش برای ارتقاء سطح عملکرد ساختمانها، نیروی وارد بر آنها با افزایش ضریب اهمیت ساختمان )I( افزایش داده میشود. از آنجا که در روش نیرویی، رفتار سازه در حوزهی غیرارتجاعی مشخص نیست، میزان و محل آسیب سازه در سطوح عملکرد متفاوت برای طراح نامعلوم خواهد بود. در این نوشتار با استفاده از تحلیلهای استات...
full textMy Resources
Journal title
volume 6 issue None
pages 111- 117
publication date 2009-02
By following a journal you will be notified via email when a new issue of this journal is published.
No Keywords
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023