ارزیابی دز ورودی پوستی و دز مؤثر بیماران در معمول ترین آزمون های رادیولوژی

Authors

  • بیجاری, سالار
  • کنعانی, مجید
Abstract:

Introduction: Nowadays, we are witnessing a progressive application of radiology techniques in various communities as well as in Iran. Medical radiological examinations are one of the important sources of public radiological dose. Entrance skin doses and effective doses for patients in diagnostic radiology examinations should be assessed for the imaging techniques optimization and patient’s radiation protection. Thus, the related radiation-protection organizations have recommended measuring the patient doses resulted from such techniques. The main purpose of this study was to investigate the patient doses in common radiographic examinations. Methods and Materials: The eight most commonly radiology examinations were selected for dosimetry calculations after reviewing and analyzing radiology examination data at an imaging center over a 3-month period. 283 patients underwent eight radiography procedures containing Chest (PA), Pelvice (AP), Abdomen (AP), Skull (AP), Thoracic Spine (AP), Thoracic Spine (LAT), Lumbar Spine (AP) and, Lumbar Spine (LAT) were selected for dose measurements. Data of exposure parameters (kVp, mAs, FFD and projection) were collected in all 283 patients. ESD (Entrance Skin Dose) and effective dose values were calculated using the analytical formula and a software indirectly (PCXMC). In addition, they compared with published works and internationally established diagnostic reference levels. Results: The average entrance skin dose (in mGy) and effective dose (in mSv) for the Chest (PA), Pelvice (AP), Abdomen (AP), Skull (AP), Thoracic Spine (AP), Thoracic Spine (LAT), Lumbar Spine (AP) and, Lumbar Spine (LAT) were (0.15-0.028), (5.4-0.87), (2.7-0.61), (2.2-0.05), (4.6-0.28), (5.1-0.20), (5.8-0.47), (6.2-0.30), respectively. Discussion and Conclusion: As expected, the patient doses in radiology exams varied consumedly because it depends on many factors including the type of medical imaging systems, examination complexity, experience and skill of the operator, and patient’s weight. In radiology, it is possible to reduce patients’ effective dose using small field of views, appropriate potential difference and mAs. There is still a need for personnel training and national guidance on good practice for optimizing of patients’ doses.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

اندازه‌گیری دز ورودی پوست و دز دریافتی ارگان‌های مختلف در لترال سفالومتری

TL dosimetry is known as one of the effective dose estimation methods in diagnostic radiology. Cephalometry is used by dentists, oral and maxillofacial surgeons to choose the appropriate treatment. The purpose of this study is to measure the entrance skin dose, and dose to different organs of the patients in cephalometry using TLD-100. The entrance skin, and organ dose were obtained by putting ...

full text

ارزیابی دز و کیفیت تصویر در آزمون های ماموگرافی در مراکز ماموگرافی شهر تهران

Abstract Background: Breast cancer is one of the most common form of cancer among women. Diagnosis in the early stage of emergence is the most effective way to reduce the mortality caused by this disease. Mammography, the safest and most accurate imaging test for the identification of breast cancer, required high quality images along applying the lowest possible dose to sensitive tissues of the...

full text

سنجش میزان دز نشتی از اتاق های رادیولوژی بیمارستانهای آموزشی دانشگاه علوم پزشکی اهواز

Introduction: X-rays can be harmful for all people who come to the radiology departments. The present study aimed to assess or measure the leakage dose in radiology departments of Ahwaz University of medical sciences. Methods and Materials: The current research was a cross-sectional study in which first, environmental dose of controlled and supervised areas were measured using Geiger-Muller ...

full text

ارزیابی دز و کیفیت تصویر در آزمون های ماموگرافی در مراکز ماموگرافی شهر تهران

سابقه و هدف: یکی از شایع ترین انواع سرطان ها در بین زنان، سرطان پستان است و موثرترین راه کاهش مرگ و میر ناشی از این بیماری، تشخیص آن در مراحل نخست پیدایش می باشد. ماموگرافی ایمن ترین و دقیق ترین آزمایش رادیولوژیکی برای تشخیص سرطان پستان می باشد، که لازمه آن بدست آوردن تصاویر با کیفیت بالا همزمان با تحمیل کمترین دز ممکن به بافت حساس پستان است. هدف این تحقیق بهینه کردن میزان پرتوگیری بیماران در آ...

full text

ارزیابی کیفیت تصویر و دز دریافتی بیماران در ماموگرافی فیلم اسکرین و ماموگرافی کامپیوتری‌شده در ایران

In this study, a quantitative parameter is introduced that evaluate three important features of a mammography exam ,contrast, spatial resolution and patient dose. Two kinds of regular mammography system used in screening mammography were evaluated in automatic exposure control mode (AEC) by this parameter. To evaluate the contrast and detail of the mammography images, the contrast-detail phanto...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 11  issue None

pages  1- 5

publication date 2016-12

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

No Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023