ارزیابی تغییرات توزیع دز در مقطع نگاری کامپیوتری با تغییر موازی سازی با استفاده از فیلم EBT و فانتوم PMMA
Authors
Abstract:
X-ray computed tomography is an imaging method which makes tomographic images with high contrast and resolution. However, CT-scans deliver much more radiation dose compared with other imaging techniques. The aim of this study was to evaluate two-dimensional dose distribution in a PMMA phantom as well as investigationof the effect ofcollimation factor on the dose distribution measuredusing GAF-Chromic EBT films. In this study the GAF-Chromic EBT films were cut to the dimensions of 6Í5 cm2 and exposured with different collimations (1, 3, 5, 7, 10 mm), while the other imaging parameters were fixed. After48 h post irradiation the films were reading using Power look 2100XL scanner model at the red channel. Then, the films were analyzed using MATLAB software.The optical density values of each film wereatributed to the related absorbed dose. Image analysis showed that the dose distribution is non-uniform in CT-scan.Results showed that the CTDIvol measured by EBT filmswas more than that of shown on theoperator console. These differences in collimations of 1 mm and 10 mm were 13.5%1.25% and 0.7%1.25% respectively. It was also resulted that the CT dose was decresed withincrease in collimation. In addition, it was observed that the minimum and maximum dose were delivered by using collimation factor of 10 mm and 1 mm respectively.
similar resources
ارزیابی تغییرات توزیع دز در مقطع نگاری کامپیوتری با تغییر موازی سازی با استفاده از فیلم ebt و فانتوم pmma
مقطع نگاری عرضی کامپیوتری(ct-scan) یکی از روشهای تصویربرداری است که در آن با استفاده از پرتو ایکس تصاویر مقطعی از بدن با تباین (کنتراست) و تفکیک پذیری (رزولوشن) بالا به دست میآید. با این حال پرتودهی ناشی از آزمونهای مقطع نگاری عرضی کامپیوتری نسبت به سایر روشهای تصویربرداری باعث انتقال دز بیشتر به افراد میشود. هدف از این مطالعه ارزیابی نحوه توزیع دز در یک فانتوم معادل بافتاز جنس پلی متیل مت...
full textاثر بربرین در تنظیم آستروسیتهای Gfap+ ناحیه هیپوکمپ موشهای صحرایی دیابتی شده با استرپتوزوتوسین
Background: Diabetes mellitus increases the risk of central nervous system (CNS) disorders such as stroke, seizures, dementia, and cognitive impairment. Berberine, a natural isoquinolne alkaloid, is reported to exhibit beneficial effect in various neurodegenerative and neuropsychiatric disorders. Moreover astrocytes are proving critical for normal CNS function, and alterations in their activity...
full textاثر بربرین در تنظیم آستروسیتهای Gfap+ ناحیه هیپوکمپ موشهای صحرایی دیابتی شده با استرپتوزوتوسین
Background: Diabetes mellitus increases the risk of central nervous system (CNS) disorders such as stroke, seizures, dementia, and cognitive impairment. Berberine, a natural isoquinolne alkaloid, is reported to exhibit beneficial effect in various neurodegenerative and neuropsychiatric disorders. Moreover astrocytes are proving critical for normal CNS function, and alterations in their activity...
full textبررسی عمق نفوذ و توزیع دز الکترونهای تکانرژی در فانتوم گردن با استفاده از کد MCNPX
Penetration and estimation of absorbed dose of electron in soft tissue is investigated in this paper. Neck phantom was simulated by MCNPX code version 2.6. The Phantom was included skin, adipose, neck tissue, neck bone and thyroid glands. Radiation source kept near to the skin surface and located in the back of the neck. Electrons were collided perpendicular to the skin surface. The curves show...
full textبررسی توزیع دوز در اسکنر ct با استفاده از فانتوم های polymethyl methacrylate (pmma) استوانه ای
مقدمه: هدف از این تحقیق، بررسی تأثیر اندازه ی بیمار بر مقدار و توزیع دوز ct (computed tomography) بر اساس فانتوم های استوانه ای استاندارد پلی متیل متااکریلیک (pmma یا polymethyl methacrylate) بود. روش ها: در این تحقیق، یک روش فیلم دوزیمتری دو بعدی با استفاده از فیلم های رادیوگرافی ارایه شد و با به کارگیری فانتوم هایی با قطرهای 10، 16، 24 و 32 سانتی متر، تأثیر اندازه ی بیمار بر توزیع دوز و میزان...
full textاندازه گیری دز جذبی الکترون در فانتوم آب به روش تمام نگاری دیجیتال با باریکه لیزر
پرتوهای پرانرژی الکترونی، از جمله پرتوهای یونسازی هستند که کاربرد فراوانی در پزشکی هستهای و برای درمان تومورهای سرطانی دارند. با این وجود، این پرتوها در طی مسیر خود در بدن بیمار میتوانند به سلولهای سالم نیز آسیب وارد نمایند. بنابراین، آگاهی از نحوه توزیع دز جذبی در فانتومی معادل با بافت بدن، نیاز اصلی طراحی درمان با استفاده از پرتوهای الکترونی است. در سالیان اخیر استفاده از روش تمامنگاری ...
full textMy Resources
Journal title
volume 3 issue 3
pages 43- 56
publication date 2015-09
By following a journal you will be notified via email when a new issue of this journal is published.
No Keywords
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023