اثر سولفید در عملکرد لجن فعال و تعیین ضرایب سینتیکی رشد میکروبی و ضرایب بازدارندگی سولفید در لجن فعال

Authors

  • Mohammadi, Mehrnoush
Abstract:

This research aims at study of the effect of sulfide on operation of one of the aerobic biological treatment processes, activated sludge. For this purpose, two pilot plant units were designed and constructed. One of these units was run for wastewater sulfide contaminant (sample), and the other one was run for wastewater without sulfide contaminant (Reference). First of all, in a quantities study, sample system was run with different influent sulfide concentrations, and compared with reference system. Then, concentration of influent sulfide was increased gradually until the inhibitory effect of sulfide on treatment process appeared. Finally, the concentration at which sulfide was inhibitory and resulted in process malfunction was determined. Also, the reference system was run with different influent COD and detention times. At the end, the behavior of pilot plants of the reference system and the sample system, were simulated with Contois model, and the microbial growth kinetic coefficient, and inhibiting coefficient of sulfide were defined.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

ارزیابی عملکرد و تعیین ضرایب بیوسنتیکی فرآیند لجن فعال تصفیه خانه فاضلاب شهر سنندج

سابقه و هدف: اثرات سوء ناشی از دفع نامناسب فاضلاب در محیط، جمع آوری فاضلاب و تصفیه آن را امری ضروری و اجتناب ناپذیر کرده است. به گونه ای که علاوه بر احداث تصفیه خانه فاضلاب، برای رسیدن به استانداردهای زیست محیطی مطلوب، لزوم ارزیابی عملکرد مداوم سیستم های تصفیه مطرح می باشد. با توجه به اینکه پل ارتباطی بین نتایج آزمایشگاهی و کاربردهای صنعتی در تصفیه فاضلاب، تعیین ضرایب بیوسنتیک است. این مطالعه ب...

full text

کمینه کردن تولید لجن در فرآیندهای لجن فعال

از جمله مشکلات اصلی فرآیندهای لجن فعال، دفع لجن مازاد تولیدی تصفیه‌خانه‌های فاضلاب است که اعتراضات زیادی را نیز به دنبال دارد. در این تحقیق کاهش تولید لجن مازاد به وسیله افزایش اکسیژن محلول حوضچه هوادهی بررسی شده است. تحقیق، در مقیاس پایلوت شامل واحدهای حوضچه ته‌نشینی اولیه، حوضچه‌هوادهی، حوضچه ته‌نشینی ثانویه و تجهیزات برگشت لجن است. حجم مفید حوضچه هوادهی برابر 360 لیتر بوده و جریان ورودی 90 ل...

full text

اثر بربرین در تنظیم آستروسیتهای Gfap+ ناحیه هیپوکمپ موشهای صحرایی دیابتی شده با استرپتوزوتوسین

Background: Diabetes mellitus increases the risk of central nervous system (CNS) disorders such as stroke, seizures, dementia, and cognitive impairment. Berberine, a natural isoquinolne alkaloid, is reported to exhibit beneficial effect in various neurodegenerative and neuropsychiatric disorders. Moreover astrocytes are proving critical for normal CNS function, and alterations in their activity...

full text

اثر بربرین در تنظیم آستروسیتهای Gfap+ ناحیه هیپوکمپ موشهای صحرایی دیابتی شده با استرپتوزوتوسین

Background: Diabetes mellitus increases the risk of central nervous system (CNS) disorders such as stroke, seizures, dementia, and cognitive impairment. Berberine, a natural isoquinolne alkaloid, is reported to exhibit beneficial effect in various neurodegenerative and neuropsychiatric disorders. Moreover astrocytes are proving critical for normal CNS function, and alterations in their activity...

full text

تعیین ضرایب بیوسینتیکی فرایند بیولوژیکی واحد لجن فعال با هوادهی گسترده در شرایط آب و هوایی گرم در تصفیه فاضلاب بیمارستانی

فاضلاب بیمارستانی جزو فاضلاب شهری ناخالص محسوب می‌شود که با توجه به گستردگی بیمارستان و تنوع بخش‌های درمانی آن و در نتیجه آلاینده‌های مختلف موجود در فاضلاب‌های بیمارستانی، تعیین ضرایب سینتیکی و راهبری تصفیه‌خانه فاضلاب بیمارستان از اهمیت زیادی برخوردار است. یکی از مهم‌ترین روش‌های تصفیه فاضلاب بیمارستانی، سیستم لجن فعال...

full text

بررسی کارآیی سیستم لجن فعال بدون برگشت لجن

سابقه و هدف: با توجه به مشکلات و محدودیت های فعلی سیستم لجن فعال با جریان ناپیوسته و پیوسته در دفع انواع فاضلاب ها، در این مقاله به ارایه یک سیستم لجن فعال بدون برگشت لجن با جریان پیوسته و دارای یک چرخه متناوب پرداخته شد و کارآیی آن به صورت یک واحد نمونه آزمایشگاهی بررسی گردید. سیستم و عملکرد آن: سیستم دارای دو مخزن 1و 2 با ابعاد، تجهیزات هوادهی، دریچه ورود فاضلاب خام و خروج پساب تصفیه شده یکسا...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 19  issue 7

pages  17- 24

publication date 2009-01

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

No Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023