effect of gold nanoparticle on percentage depth dose enhancement on megavoltage energy in magica polymer gel dosimeter

Authors

m. mahdavi ph.d, physics depart- ment, mazandaran uni- versity, babolsar, iran

m. khadem-abolfazli m.sc, para medical de- partment, babol univer- sity of medical sciences, babol, iran

s. r. m. mahdavi ph.d, medical physics department, tehran university of medical sci- ences, tehran, iran

gh. ataei m.sc, para medical de- partment, babol univer- sity of medical sciences, babol, iran

abstract

background: radiation-sensitive polymer gels are among the most promising three-dimensional dose verification tools and tissue-like phantom developed to date. objective: the aim of this study is an investigating of percentage depth dose enhancement within the gel medium with used of conformal distribution gold nanoparticle as contrast agents by high atomic number material. methods: in this work the normoxic polymer gel dosimeter magica tissue- equivalence was first theoretically verified using mcnpx monte carlo code and experimentally by percentage depth dose curves within the gel medium. then gold nanoparticles (gnps) of 50nm diameter with different concentrations of 0.1mm, 0.2mm, and 0.4mm were embedded in magica gel and irradiated by 18mv photon beam. results: experimental results have shown dose increase of 10%, 2% and 4% in 0.1mm, 0.2mm and 0.4mm concentrations, respectively. simulation results had good agreement in the optimum concentration of 0.1mm. the largest error between experi- mental and simulation results was equal to 9.28% stood for 0.4mm concentration. conclusion: the results showed that the optimum concentration of gold nanoparticles to achieve maximum absorbed dose in both experimental and simula- tion was 0.1 mm and so it can be used for clinical studies.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Effect of Gold Nanoparticle on Percentage Depth Dose Enhancement On Megavoltage Energy in MAGICA Polymer Gel Dosimeter

Background: Radiation-sensitive polymer gels are among the most promising three-dimensional dose verification tools and tissue-like phantom developed to date.Objective: The aim of this study is an investigating of percentage depth dose enhancement within the gel medium with used of conformal distribution gold nanoparticle as contrast agents by high atomic number material.Methods: In this work t...

full text

Effect of Gold Nanoparticle on Percentage Depth Dose Enhancement On Megavoltage Energy in MAGICA Polymer Gel Dosimeter

BACKGROUND Radiation-sensitive polymer gels are among the most promising three-dimensional dose verification tools and tissue-like phantom developed to date. OBJECTIVE The aim of this study is an investigating of percentage depth dose enhancement within the gel medium with used of conformal distribution gold nanoparticle as contrast agents by high atomic number material. METHODS In this wor...

full text

Evaluation of Gold Nanoparticle Size Effect on Dose Enhancement Factor in Megavoltage Beam Radiotherapy Using MAGICA Polymer Gel Dosimeter

Background: Gold nanoparticles (GNPs) are among the most promising radiosensitive materials in radiotherapy. Studying the effective sensitizing factors such as nanoparticle size, concentration, surface features, radiation energy and cell type can help to optimize the effect and possible clinical application of GNPs in radiation therapy. In this study, the radiation sensitive polymer gel was use...

full text

Dose enhancement effect of gold nanoparticles on MAGICA polymer gel in mega voltage radiation therapy

Background: Radiation-sensitive polymer gels are among the most promising three-dimensional dose verification tools and tissue-like developed to date. Among the special features of this type of dosimeters, is be doped with other elements or chemicals which made them appropriate for investigating of dose enhancement with contrast agents, by high atomic number. Material and Methods: In this study...

full text

Effect of gold nanoparticles on dose enhancement of 6 Mv X-rayin MAGIC_f polymer gel dosimeter

Introduction: Currently, the potential application of gold nanoparticles (AuNPs) to increase the efficiency of radiation therapy have been investigated. However, the loss of an appropriate method to estimate the dose distribution in nanoparticle laden tissue limits the applicability of nanoparticles in radiotherapy clinics. Polymer gel dosimetry provides an accurate and precise...

full text

dose enhancement effect of gold nanoparticles on magica polymer gel in mega voltage radiation therapy

background: radiation-sensitive polymer gels are among the most promising three-dimensional dose verification tools and tissue-like developed to date. among the special features of this type of dosimeters, is be doped with other elements or chemicals which made them appropriate for investigating of dose enhancement with contrast agents, by high atomic number. material and methods: in this study...

full text