effect of gold nanoparticle on percentage depth dose enhancement on megavoltage energy in magica polymer gel dosimeter
Authors
abstract
background: radiation-sensitive polymer gels are among the most promising three-dimensional dose verification tools and tissue-like phantom developed to date. objective: the aim of this study is an investigating of percentage depth dose enhancement within the gel medium with used of conformal distribution gold nanoparticle as contrast agents by high atomic number material. methods: in this work the normoxic polymer gel dosimeter magica tissue- equivalence was first theoretically verified using mcnpx monte carlo code and experimentally by percentage depth dose curves within the gel medium. then gold nanoparticles (gnps) of 50nm diameter with different concentrations of 0.1mm, 0.2mm, and 0.4mm were embedded in magica gel and irradiated by 18mv photon beam. results: experimental results have shown dose increase of 10%, 2% and 4% in 0.1mm, 0.2mm and 0.4mm concentrations, respectively. simulation results had good agreement in the optimum concentration of 0.1mm. the largest error between experi- mental and simulation results was equal to 9.28% stood for 0.4mm concentration. conclusion: the results showed that the optimum concentration of gold nanoparticles to achieve maximum absorbed dose in both experimental and simula- tion was 0.1 mm and so it can be used for clinical studies.
similar resources
Effect of Gold Nanoparticle on Percentage Depth Dose Enhancement On Megavoltage Energy in MAGICA Polymer Gel Dosimeter
Background: Radiation-sensitive polymer gels are among the most promising three-dimensional dose verification tools and tissue-like phantom developed to date.Objective: The aim of this study is an investigating of percentage depth dose enhancement within the gel medium with used of conformal distribution gold nanoparticle as contrast agents by high atomic number material.Methods: In this work t...
full textEffect of Gold Nanoparticle on Percentage Depth Dose Enhancement On Megavoltage Energy in MAGICA Polymer Gel Dosimeter
BACKGROUND Radiation-sensitive polymer gels are among the most promising three-dimensional dose verification tools and tissue-like phantom developed to date. OBJECTIVE The aim of this study is an investigating of percentage depth dose enhancement within the gel medium with used of conformal distribution gold nanoparticle as contrast agents by high atomic number material. METHODS In this wor...
full textEvaluation of Gold Nanoparticle Size Effect on Dose Enhancement Factor in Megavoltage Beam Radiotherapy Using MAGICA Polymer Gel Dosimeter
Background: Gold nanoparticles (GNPs) are among the most promising radiosensitive materials in radiotherapy. Studying the effective sensitizing factors such as nanoparticle size, concentration, surface features, radiation energy and cell type can help to optimize the effect and possible clinical application of GNPs in radiation therapy. In this study, the radiation sensitive polymer gel was use...
full textDose enhancement effect of gold nanoparticles on MAGICA polymer gel in mega voltage radiation therapy
Background: Radiation-sensitive polymer gels are among the most promising three-dimensional dose verification tools and tissue-like developed to date. Among the special features of this type of dosimeters, is be doped with other elements or chemicals which made them appropriate for investigating of dose enhancement with contrast agents, by high atomic number. Material and Methods: In this study...
full textEffect of gold nanoparticles on dose enhancement of 6 Mv X-rayin MAGIC_f polymer gel dosimeter
Introduction: Currently, the potential application of gold nanoparticles (AuNPs) to increase the efficiency of radiation therapy have been investigated. However, the loss of an appropriate method to estimate the dose distribution in nanoparticle laden tissue limits the applicability of nanoparticles in radiotherapy clinics. Polymer gel dosimetry provides an accurate and precise...
full textdose enhancement effect of gold nanoparticles on magica polymer gel in mega voltage radiation therapy
background: radiation-sensitive polymer gels are among the most promising three-dimensional dose verification tools and tissue-like developed to date. among the special features of this type of dosimeters, is be doped with other elements or chemicals which made them appropriate for investigating of dose enhancement with contrast agents, by high atomic number. material and methods: in this study...
full textMy Resources
Save resource for easier access later
Journal title:
journal of biomedical physics and engineeringجلد ۳، شماره ۲ Jun، صفحات ۰-۰
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023