evaluating performance of algorithms in lung imrt: a comparison of monte carlo, pencil beam, superposition, fast superposition and convolution algorithms
Authors
abstract
background: inclusion of inhomogeneity corrections in intensity modulated small fields always makes conformal irradiation of lung tumor very complicated in accurate dose delivery. objective: in the present study, the performance of five algorithms via monte carlo, pencil beam, convolution, fast superposition and superposition were evaluated in lung cancer intensity modulated radiotherapy planning. materials and methods: treatment plans for ten lung cancer patients previously planned on monte carlo algorithm were re-planned using same treatment planning indices (gantry angel, rank, power etc.) in other four algorithms. results: the values of radiotherapy planning parameters such as mean dose, volume of 95% isodose line, conformity index, homogeneity index for target, maximum dose, mean dose; %volume receiving 20gy or more by contralateral lung; % volume receiving 30 gy or more; % volume receiving 25 gy or more, mean dose received by heart; %volume receiving 35gy or more; %volume receiving 50gy or more, mean dose to easophagous; % volume receiving 45gy or more, maximum dose received by spinal cord and total monitor unit, volume of 50 % isodose lines were recorded for all ten patients. performance of different algorithms was also evaluated statistically. conclusion: mc and pb algorithms found better as for tumor coverage, dose distribution homogeneity in planning target volume and minimal dose to organ at risks are concerned. superposition algorithms found to be better than convolution and fast superposition. in the case of tumors located centrally, it is recommended to use monte carlo algorithms for the optimal use of radiotherapy.
similar resources
Evaluating Performance of Algorithms in Lung IMRT: A Comparison of Monte Carlo, Pencil Beam, Superposition, Fast Superposition and Convolution Algorithms
Background: Inclusion of inhomogeneity corrections in intensity modulated small fields always makes conformal irradiation of lung tumor very complicated in accurate dose delivery.Objective: In the present study, the performance of five algorithms via Monte Carlo, Pencil Beam, Convolution, Fast Superposition and Superposition were evaluated in lung cancer Intensity Modulated Radiotherapy plannin...
full textPerformance Evaluation of Algorithms in Lung IMRT: A comparison of Monte Carlo, Pencil Beam, Superposition, Fast Superposition and Convolution Algorithms
BACKGROUND Inclusion of inhomogeneity corrections in intensity modulated small fields always makes conformal irradiation of lung tumor very complicated in accurate dose delivery. OBJECTIVE In the present study, the performance of five algorithms via Monte Carlo, Pencil Beam, Convolution, Fast Superposition and Superposition were evaluated in lung cancer Intensity Modulated Radiotherapy planni...
full textDosimetry of oblique tangential photon beams calculated by superposition/convolution algorithms: a Monte Carlo evaluation
Although there are many works on evaluating dose calculations of the anisotropic analytical algorithm (AAA) using various homogeneous and heterogeneous phantoms, related work concerning dosimetry due to tangential photon beam is lacking. In this study, dosimetry predicted by the AAA and collapsed cone convolution (CCC) algorithm was evaluated using the tangential photon beam and phantom geometr...
full textPoint Dose Measurement for Verification of Treatment Planning System using an Indigenous Heterogeneous Pelvis Phantom for Clarkson, Convolution, Superposition, and Fast Superposition Algorithms
Background: Nowadays, advanced radiotherapy equipment includes algorithms to calculate dose. The verification of the calculated doses is important to achieve accurate results. Mostly homogeneous dosimetric phantoms are available commercially which do not mimic the actual patient anatomy; therefore, an indigenous heterogeneous pelvic phantom mimicking actual human pelvic region has been used to ...
full textMonte Carlo vs. Pencil Beam based optimization of stereotactic lung IMRT
BACKGROUND The purpose of the present study is to compare finite size pencil beam (fsPB) and Monte Carlo (MC) based optimization of lung intensity-modulated stereotactic radiotherapy (lung IMSRT). MATERIALS AND METHODS A fsPB and a MC algorithm as implemented in a biological IMRT planning system were validated by film measurements in a static lung phantom. Then, they were applied for static l...
full textDose Calculations for Lung Inhomogeneity in High-Energy Photon Beams and Small Beamlets: A Comparison between XiO and TiGRT Treatment Planning Systems and MCNPX Monte Carlo Code
Introduction Radiotherapy with small fields is used widely in newly developed techniques. Additionally, dose calculation accuracy of treatment planning systems in small fields plays a crucial role in treatment outcome. In the present study, dose calculation accuracy of two commercial treatment planning systems was evaluated against Monte Carlo method. Materials and Methods Siemens Once or linea...
full textMy Resources
Save resource for easier access later
Journal title:
journal of biomedical physics and engineeringجلد ۶، شماره ۳ Sep، صفحات ۰-۰
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023