cold vapor atomic absorption determination of hg in crude oil and gasoline samples after solid phase extraction using modified disks

Authors

mahmood payehghadr

homa shafiekhani

ali reza sabouri

abdoll mohammad attaran

mohammad kazem rofouei

abstract

a facile and highly efficient method have been developed for the preconcentration of the mercury content in crude oil and gasoline samples after digestion with microwave-assisted digestion. octadecyl silica membrane disk has been modified by the recently synthesized triazene ligand, (e)-1-(2-ethoxyphenyl)-3-(4-nitrophenyl) triaz-1-ene (ent), then the modified membrane was used for the preconcentration of mercury(ii) ions and cold vapor atomic absorption spectrometry (cv-aas) have been used to determine the hg (ii) ion. solution studies of ent with a series of metal ions have been done in advance, and the results showed a strong affinity of ent to the mercury ion. for solid phase extraction, ph of sample 6.0, flow rates 3.0 ml / min, enrichment factor 240, capacity of modified disk 690 µg hg per 8.0 mg of ligand, eluent solvent 5.0 ml, 1.5m hclo4, and the amount of the ligand 8.0 – 10.0 mg, have been optimized. a linear calibration curve has been obtained in the range of 0.80 – 65 µg / l with r2 = 0.9991 and the limit of detection (lod) based on three times the standard deviation of the blank was 0.25 µg / l. the relative standard deviation (rsd) for the determination of 50 ml aqueous solution containing 0.5 µg / lhg (ii) found to be 1.0 % while a rsd value of 1.9% have been obtained for the determination of 0.1 µg / l hg (ii) (n=3). the characteristic concentration is 1.2 µg / lin the original samples. the newly developed method was successfully applied to the determination of mercury ion in real crude oil samples, which are very important in environment and industries process.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Cold Vapor Atomic Absorption Determination of Hg in Crude Oil and Gasoline Samples after Solid Phase Extraction Using Modified Disks

A facile and highly efficient method have been developed for the preconcentration of the mercury content in crude oil and gasoline samples after digestion with microwave-assisted digestion. Octadecyl silica membrane disk has been modified by the recently synthesized triazene ligand, (E)-1-(2-ethoxyphenyl)-3-(4-nitrophenyl) triaz-1-ene (ENT), then the modified membrane was used for the preco...

full text

solid phase extraction of trace copper in aqueous samples using c18 membrane disks modified by benzildithiosemicarbazone prior to flame atomic absorption spectrometric (faas) determination

a highly convenient, selective and sensitive procedure for pre-concentration, separation and determination of sub-ppm levels of cu 2+ in aqueous samples based on modification of octadecyl silica bonded phase membrane (osbpm) disks is described using benzildithiosemicarbazone  (bdsc) as a powerful modifier. it was revealed that each loaded osbpm disk with 6.0 mg of bdsc serves as excellent bead ...

full text

Solid Phase Extraction Using Modified Magnetic Iron Oxide Nanoparticles for Extraction and Spectrofluorimetric Determination of Carvedilol in Human Plasma Samples

A new analytical approach was developed involving magnetic solid–phase extraction and spectrofluorimetric determination of carvedilol in human plasma samples. A plasma sample was prepared and adjusted to pH 8.2–10, then carvedilol was quickly extracted using iron oxide magnetic nanoparticles modified by the surfactant cetyltrimethylammonium bromide and determined to apply spectrofluorimetry...

full text

Determination of As, Se and Hg in Waters by Hydride Generation/Cold Vapor Atomic Absorption Spectroscopy

Contamination of industrial and municipal water supplies with arsenic (As), selenium (Se), and mercury (Hg) can occur from natural deposits, industrial discharge, runoff from mining, landfill and agricultural operations. Consumption of contaminated water can cause skin damage (As), kidney and nervous system damage (Hg) and numbness in the fingers and toes (Se).1 The U.S. Environmental Protectio...

full text

Slurry Sampling for Hg Determination in Sediments, Sewage Sludge and Coal Samples by Cold Vapor Atomic Absorption Spectrometry

Um método simples e robusto para a determinação de Hg em amostras ambientais por espectrometria de absorção atômica com geração de vapor frio diretamente de suspensões ácidas é proposto. Após redução do tamanho das partículas da amostra para ≤ 50 μm em gral de ágata, dois procedimentos foram utilizados para a preparação das suspensões: com 6,7% v/v de ácido nítrico ou 10% v/v de água-régia mais...

full text

Determination of Trace Copper(II) in Food Samples by Flame Atomic Absorption Spectrometry after Cloud Point Extraction

A new method for the determination of trace copper(II) in food samples by Cloud Point Extraction(CPE) combined with Flame Atomic Absorption Spectrometry(FAAS) is presented and evaluated. The method is based on the fact that hydrophobic complex of copper(II) with sodium diethyldithiocarbamate (DDTC) was formed at pH 6.0 and subsequently the hydrophobic complex was extracted into surfactant-r...

full text

My Resources

Save resource for easier access later


Journal title:
iranian journal of chemistry and chemical engineering (ijcce)

Publisher: iranian institute of research and development in chemical industries (irdci)-acecr

ISSN 1021-9986

volume 33

issue 2 2014

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023