catalytic spectrophotometric determination of traces of tellurium (iv)
Authors
abstract
a simple, rapid and sensitive method has been developed for determination of trances of tellurium (vi) (0.096-1.250 mg/ml) based on its catalytic effect on the reduction reaction of toluidine blue by sulfide ion at ph 4. the reaction is monitored spectrophotometrically by measuring the decrease in absorbance of the dyestuff at 628 nm by the fixed time method. the detection limit is 80 ng/ml and the relative standard deviation for 1 mg/ml tellurium is 2.2%.
similar resources
Catalytic Spectrophotometric Determination of Traces of Tellurium (IV)
A Simple, rapid and sensitive method has been developed for determination of trances of tellurium (VI) (0.096-1.250 mg/mL) based on its catalytic effect on the reduction reaction of toluidine blue by sulfide ion at pH 4. The reaction is monitored spectrophotometrically by measuring the decrease in absorbance of the dyestuff at 628 nm by the fixed time method. The detection...
full textCatalytic Determination of Traces of Tellurium (IV) Using the Reduction of Lauth’s Violet with Sodium Sulfide
A simple, rapid and sensitive method has been developed for determination of traces of tellurium (IV) (7.0-120.0 ng/ml) based on it’s catalytic effect on the reduction reaction of lauth’s violet by sulfide ion at pH 4.2. The reaction is monitored spectrophotometrically by measuring the decrease in absorbance of lauth’s viole at 600 nm by the fixed time method. The detection limit is 5.0 ng/ml a...
full textcatalytic determination of traces of tellurium (iv) using the reduction of lauth’s violet with sodium sulfide
a simple, rapid and sensitive method has been developed for determination of traces of tellurium (iv) (7.0-120.0 ng/ml) based on it’s catalytic effect on the reduction reaction of lauth’s violet by sulfide ion at ph 4.2. the reaction is monitored spectrophotometrically by measuring the decrease in absorbance of lauth’s viole at 600 nm by the fixed time method. the detection limit is 5.0 ng/ml a...
full textCatalytic Spectrophotometric Determination of Chromium
chromium(III) up to 100 ng mL−1, and for chromium(VI) up to 200 ng mL−1) were obtained, using the “fixed time” method with detection limits of 4.9 ng mL−1 and 3.8 ng mL−1, respectively. The results suggest that at the reaction conditions chromium(VI) is reduced and chromium(III) is oxidized to an intermediate oxidation state and the catalytic action of chromium is due to the formation of an act...
full textcatalytic spectrophotometric determination of vanadium (iv) based on the oxidation of alkali blue by potassium bromate
a simple, rapid and sensitive spectrophotometric method has been proposed for the determinationof vanadium (iv). the method is based on the catalytic effect of v (iv) on the oxidation of alkali blue bypotassium bromate at ph 4. the rate of decrease in the absorbance of alkali blue (at 572 nm) wasproportional to the concentration of v (iv) in the range of 100-6000 ng ml-1. the detection limit wa...
full textcomparison of catalytic activity of heteropoly compounds in the synthesis of bis(indolyl)alkanes.
heteropoly acids (hpa) and their salts have advantages as catalysts which make them both economically and environmentally attractive, strong br?nsted acidity, exhibiting fast reversible multi-electron redox transformations under rather mild conditions, very high solubility in polar solvents, fairly high thermal stability in the solid states, and efficient oxidizing ability, so that they are imp...
15 صفحه اولMy Resources
Save resource for easier access later
Journal title:
iranian journal of chemistry and chemical engineering (ijcce)Publisher: iranian institute of research and development in chemical industries (irdci)-acecr
ISSN 1021-9986
volume 14
issue 1 1995
Hosted on Doprax cloud platform doprax.com