a sensor, based on multi-wall carbon nanotubes modified glassy carbon electrode (mwcnt/gce), was developed for determination of fenitrothion. determining the surface area of mwcnt/gce showed that this surface is three times more active than that of a glassy carbon electrode. the experimental parameters, such as the amount of mwcnts, ph of the fenitrothion solution, preconcentration potential and preconcentration time were optimized. under these conditions, reduction current showed a linear relationship with the concentration of fenitrothion in a range of 0.01-5.0 mm, with a detection limit of 6.4 nm. the modified electrode also exhibited good stability and reproducibility. the effects of possible interferents were studied and found to be negligible, indicative of high selectivity of the electrode. this sensor was also successfully employed for determination of fenitrothion in soil and teff samples with recovery values in the range of 88.0-93.3% and 86.7-91.4%, respectively.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Electrochemical Sensor for Determination of Fenitrothion at Multi-wall Carbon Nanotubes Modified Glassy Carbon Electrode

A sensor, based on multi-wall carbon nanotubes modified glassy carbon electrode (MWCNT/GCE), was developed for determination of fenitrothion. Determining the surface area of MWCNT/GCE showed that this surface is three times more active than that of a glassy carbon electrode. The experimental parameters, such as the amount of MWCNTs, pH of the fenitrothion solution, preconcentration potential an...

full text

Electrochemical Sensor for Determination of Fenitrothion at Multi-wall Carbon Nanotubes Modified Glassy Carbon Electrode

A sensor, based on multi-wall carbon nanotubes modified glassy carbon electrode (MWCNT/GCE), was developed for determination of fenitrothion. Determining the surface area of MWCNT/GCE showed that this surface is three times more active than that of a glassy carbon electrode. The experimental parameters, such as the amount of MWCNTs, pH of the fenitrothion solution, preconcentration potential an...

full text

A New Hydroxylamine Electrochemical Sensor Based on an Oxadiazol Derivative and Multi-wall Carbon Nanotuhes Modified Glassy Carbon Electrode

A new hydroxylamine sensor has been fabricated by immobilizing oxadiazol denvative at the surface ol aglassy carbon electrode (GCE) modified by multi-wall carbon nanotube (MIVCNT). The adsorbed thin Illms oroxadiazol derivative on the MWCNT modified GCE show a pair of peaks with surface confined characierisnus.The oxadiazol derivative MWCNI (OMWCNT) modified GCE shows highly catalytic activity ...

full text

Electrochemical behavior of levodopa at multi-wall carbon nanotubes-quantum dots modified glassy carbon electrodes.

A multi-wall carbon nanotubes (MWNTs)-quantum dots (QDs) composite-modified glassy carbon electrode (GCE) was prepared. The complex was characterized by transmission electron microscopy (TEM). The electrochemical behavior of levodopa at MWNTs and QDs-modified GCEs (MWNTs-QDs/GCE) was studied by cyclic voltammetry (CV) and chronocoulometry (CC). It was found that its electrochemical behavior was...

full text

Electrochemical behavior and voltammetric determination of 2,4,6-triaminopyrimidine at glassy carbon electrode modified with multi-walled carbon nanotubes/nafion.

A multi-wall carbon nanotubes (MWCNTs) composite with Nafion was modified on a glass carbon electrode. The modified electrode was then used as a voltammetric sensor in detecting 2,4,6-triaminopyrimidine (TAP). The surface morphology of the Nafion/MWCNTs composite film was characterized by atomic force microscopy (AFM), and the electrochemical behavior of TAP at this sensor was investigated in d...

full text

Electrochemical Determination of Glycoalkaloids Using a Carbon Nanotubes-Phenylboronic Acid Modified Glassy Carbon Electrode

A versatile strategy for electrochemical determination of glycoalkaloids (GAs) was developed by using a carbon nanotubes-phenylboronic acid (CNTs-PBA) modified glassy carbon electrode. PBA reacts with α-solanine and α-chaconine to form a cyclic ester, which could be utilized to detect GAs. This method allowed GA detection from 1 μM to 28 μM and the detection limit was 0.3 μM. Affinity interacti...

full text

My Resources

Save resource for easier access later


Journal title:
analytical and bioanalytical chemistry research

Publisher: iranian chemical society

ISSN

volume 2

issue 2 2015

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023