in order to preparing strontium ion selective electrode 6-(4- nitropheny1)-2-pheny14, 4- dipropy1-3, 5-diaza-bicyclo [3, 1, 0] hex-2-ene (npdbh) was used as an ionophore. this electrode responds to sr (ii)ion with a sensitivity of 28.2 ± 0.5 mv/decade over the range 1.0 x 10-6 to 1.0 mat ph 3.0-10.0. thelimit of detection was 2.4 x 10-7 m. the influences of membrane composition, the ph of the testsolution, the temperature effect and the interfering ions on the electrode performance for the proposedelectrode were investigated. in the next step, electrolyte solution system srcl2, kc1, h20 in the highconcentration range were thermodynamically investigated. the thermodynamic investigations wereperformed by evaluation of potentiometric experimental data, successfiffly.
similar resources
Construction of S?-Selective Electrode and Thermodynamic Study of the Ternary Aqueous Mixed Electrolyte System (SrCl2, KG, H20) Using Potentiometric Method
In order to preparing strontium ion selective electrode 6-(4- nitropheny1)-2-pheny14, 4- dipropy1-3, 5-diaza-bicyclo [3, 1, 0] hex-2-ene (NPDBH) was used as an ionophore. This electrode responds to Sr (II)ion with a sensitivity of 28.2 ± 0.5 mV/decade over the range 1.0 x 10-6 to 1.0 Mat pH 3.0-10.0. Thelimit of detection was 2.4 x 10-7 M. The influences of membrane composition, the pH of the t...
full textConstruction of Cu2+-selective electrode and thermodynamic study of the ternary aqueous mixed electrolyte system (CuCl2, KCl, H2O) using nanocomposite-based potentiometric sensor
A nanocomposite membrane Cu2+ ion-selective electrode has been constructed using a new compound ethyl 1,2,3,4-tetrahydro-4-(4-methoxyphenyl)-6-methyl-2-oxopyrimidine-5-carboxylat (ETMOC) as a neutral ionophore. The electrode works properly. It responds to Cu2+ ion with a sensitivity of 29.5 ± 0.2 mV/decade over the range 1.0 × 10−9 to 5.0 × 10−1M at p...
full textConstruction of Cu2+-selective electrode and thermodynamic study of the ternary aqueous mixed electrolyte system (CuCl2, KCl, H2O) using nanocomposite-based potentiometric sensor
A nanocomposite membrane Cu2+ ion-selective electrode has been constructed using a new compound ethyl 1,2,3,4-tetrahydro-4-(4-methoxyphenyl)-6-methyl-2-oxopyrimidine-5-carboxylat (ETMOC) as a neutral ionophore. The electrode works properly. It responds to Cu2+ ion with a sensitivity of 29.5 ± 0.2 mV/decade over the range 1.0 × 10−9 to 5.0 × 10−1M at p...
full textconstruction of cu2+-selective electrode and thermodynamic study of the ternary aqueous mixed electrolyte system (cucl2, kcl, h2o) using nanocomposite-based potentiometric sensor
a nanocomposite membrane cu2+ ion-selective electrode has been constructed using a new compound ethyl 1,2,3,4-tetrahydro-4-(4-methoxyphenyl)-6-methyl-2-oxopyrimidine-5-carboxylat (etmoc) as a neutral ionophore. the electrode works properly. it responds to cu2+ ion with a sensitivity of 29.5 ± 0.2 mv/decade over the range 1.0 × 10−9 to 5.0 × 10−1m at ph 3.0-8.0. the limit of detection was 4.5 × ...
full texta study on construction of iranian life tables: the case study of modified brass logit system
چکیده ندارد.
15 صفحه اولThermodynamic Study of the Ternary Electrolyte (1-Butyl-3-methylimidazolium chloride + sodium chloride + Water) System Using Potentiometric Measurements
In this paper, the thermodynamic properties of the aqueous mixed electrolyte system containing 1-butyl-3-methylimidazolium chloride ([BMIm]Cl) and NaCl are reported based on the potentiometric method. The potentiometric measurements were performed on the galvanic cells without liquid junction of the type:Ag-AgCl [BMIm]Cl (m1), NaCl(m2), H2O│IL-...
full textMy Resources
Save resource for easier access later
Journal title:
journal of physical & theoretical chemistryISSN
volume 8
issue 2 2011
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023