an important need in radiation therapy is a fast and accurate treatment planning system. this system using ct data and characteristics of the radiation beam, calculates the dose in all points of the patient’s volume. two main factors in planning system are “accuracy” and “speed”. according to these factors, various generation of treatment planning systems are developed. this article is the review of fast monte carlo treatment planning systems which are accurate and fast have both factors at the same time. monte carlo techniques are based on the transport of each individual particle (e.g. photon or electron) in the tissue. the transport of the particle is done using the physics of interactions of the particles with matter. other techniques transport the particles as a group. for a typical dose calculation in radiation therapy the code has to transport some few million particles which take few hours therefore the monte carlo techniques are accurate but slow for clinical use. in recent years with development of the “fact” monte carlo the system one is able to perform dose calculation in reasonable time for clinical use. the acceptable time for dose calculation is in the range of the one minute. there is currently a growing interest in fast monte carlo treatment planning systems and there are many commercial treatment planning systems the perform dose calculation in radiation therapy based on monte carlo technique.
similar resources
Review of Fast Monte Carlo Codes for Dose Calculation in Radiation Therapy Treatment Planning
An important requirement in radiation therapy is a fast and accurate treatment planning system. This system, using computed tomography (CT) data, direction, and characteristics of the beam, calculates the dose at all points of the patient's volume. The two main factors in treatment planning system are accuracy and speed. According to these factors, various generations of treatment planning syst...
full textCommissioning a fast Monte Carlo dose calculation algorithm for lung cancer treatment planning
A commercial Monte Carlo simulation package, NXEGS 1.12 (NumeriX LLC, New York, NY), was commissioned for photon-beam dose calculations. The same sets of measured data from 6-MV and 18-MV beams were used to commission NXEGS and Pinnacle 6.2b (Philips Medical Systems, Andover, MA). Accuracy and efficiency were compared against the collapsed cone convolution algorithm implemented in Pinnacle 6.2b...
full textFast CPU-based Monte Carlo simulation for radiotherapy dose calculation.
Monte-Carlo (MC) simulations are considered to be the most accurate method for calculating dose distributions in radiotherapy. Its clinical application, however, still is limited by the long runtimes conventional implementations of MC algorithms require to deliver sufficiently accurate results on high resolution imaging data. In order to overcome this obstacle we developed the software-package ...
full textGPU-based fast Monte Carlo simulation for radiotherapy dose calculation.
Monte Carlo (MC) simulation is commonly considered to be the most accurate dose calculation method in radiotherapy. However, its efficiency still requires improvement for many routine clinical applications. In this paper, we present our recent progress toward the development of a graphics processing unit (GPU)-based MC dose calculation package, gDPM v2.0. It utilizes the parallel computation ab...
full textFast CPU-based Monte Carlo simulation for radiotherapy dose calculation
Monte-Carlo (MC) simulations are considered to be the most accurate method for calculating dose distributions in radiotherapy. Its clinical application, however, still is limited by the long runtimes conventional implementations of MC algorithms require to deliver sufficiently accurate results on high resolution imaging data. In order to overcome this obstacle we developed the software-package ...
full textMonte Carlo calculation of shielding parameters for fast neutrons in newly developed heavy concretes
Introduction: The role of radiotherapy as a part of cancer management increases every year around the world. Thus, Radiation protection in the design of radiotherapy rooms are of great importance. Materials and Methods: In present study using Monte Carlo method, MCNPX code, fourteen types of developed high density concretes with densities ranging from 2.45 ...