a quick and sensitive liquid chromatography–tandem mass spectrometry (lc-ms) method for the determination of enalapril and enalaprilat in human plasma: application to a bioequivalence study

Authors

hossein danafar

school of pharmacy zanjan university mehrdad hamidi

school of pharmacy zanjan university

abstract

a rapid and sensitive liquid chromatography–tandem mass spectrometry (lc-ms) method for the estimation of enalapril and enalaprilat in human plasma. detection of analytes was achieved by tandem mass spectrometry with electrospray ionization (esi) interface in positive ion mode was operated under the multiple-reaction monitoring mode. sample pretreatment involved in a one-step protein precipitation (ppt) with percholoric acid (hclo4) of 0.15ml plasma. the reconstituted samples were chromatographed on c18 column by pumping methanol: water: acid formic74:24:2 (v/v)at a flow rate of 0.2 ml/min.each plasma samplewaschromatographedwithin1.25min.the standard curves were found to be linear in the range of 0.1–20ng/ml for enalapril and enalaprilat with mean correlation coefficient of ≥0.999 for each analyte. the intra-day and inter-day precision and accuracy results were well within the acceptable limits.the limit of quantification(loq) was 0.1ng/ml for enalapril andenalaprilat. the mean (sd) cmax, tmax, auc0–tand auc0–∞ values of enalaprilversusenalaprilatafter administration of the 10 mg enalapril, respectively, were in this manner: 141.33(3.51) versus73.33 (5.03) ng/ml, 1.15(1.45) versus 4.12 (1.74) hours, 142.57 (34.34) versus 425.94(13.09) ng/ml/h, and 150.74 (16.69) versus 455.80 (65.11) ng/ml/h. the mean (sd) t1/2 was 2.72 (2.01) hours for the enalapril and 6.34 (2.13) hours for the enalaprilat. the developed assay method was successfully applied to a pharmacokinetic study in human male volunteers.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

A quick and Sensitive Liquid Chromatography–tandem Mass Spectrometry (LC-MS) Method for the Determination of Enalapril and Enalaprilat in Human Plasma: Application to a Bioequivalence Study

A rapid and sensitive liquid chromatography–tandem mass spectrometry (LC-MS) method for the estimation of enalapril and enalaprilat in human plasma. Detection of analytes was achieved by tandem mass spectrometry with electrospray ionization (ESI) interface in positive ion mode was operated under the multiple-reaction monitoring mode. Sample pretreatment involved in a one-step protein precipitat...

full text

A quick and Sensitive Liquid Chromatography–Tandem Mass Spectrometry (LC-MS) Method for the Determination of Enalapril and Enalaprilat in Human Plasma: Application to a Bioequivalence Study

A rapid and sensitive liquid chromatography–tandem mass spectrometry (LC-MS) method was developed for the estimation of enalapril and enalaprilat in human plasma. Detection of analytes was achieved by tandem mass spectrometry with electrospray ionization (ESI) interface in positive ion mode was operated under the multiple-reaction monitoring mode. Sample pretreatment involved in a one-step prot...

full text

Liquid chromatography–tandem mass spectrometry (LC-MS) method for the assignment of enalapril and enalaprilat in human plasma

A rapid and sensitive liquid chromatography–tandem mass spectrometry (LC-MS) method was developed for the determination of enalapril and enalaprilat in human plasma. Detection of analytes was achieved by tandem mass spectrometry with electrospray ionization (ESI) interface in positive ion mode which was operated under the multiple-reaction monitoring mode. Sample pretreatment was involved...

full text

A Quick and Sensitive Liquid Chromatography-Tandem Mass Spectrometry (LC-MS) Method for the Evaluation of Two Formulations of Amlodipine and Atorvastatin in Healthy Male Volunteers

An open-label, single-dose, randomized, 2-way crossover study was conducted in fasted healthy Iranian male volunteers. Eligible participants randomly assigned in a 1:1 ratio to be given one tablet of the test or reference formulation, followed by a 2-week washout period and administration of the exchange formulation. A quick and susceptible Liquid Chromatography–tandem Mass Spectro...

full text

Development and Application of a Validated Liquid Chromatography-Mass Spectrometry Method for the Determination of Dexchlorpheniramine Maleate in Human Plasma

     A convenient liquid chromatographic-single Quadrupole mass spectrometric (LC-MS) method was developed and validated for dexchlorpheniramine maleate (INN name: chlorphenamine) determination in human plasma. The need for just a single liquid-liquid extraction with ethyl acetate and being highly sensitive were the advantages of this method. The linearity was also excellent over the range of 1...

full text

pharmacokinetics and bioequivalence of methotrexate in human plasma studied by liquid chromatography-mass spectrometry (lc-ms)

background methotrexate is a folic acid antagonist that has been in clinical use for five decades. its use in patients with brain tumors is primarily confined to primary central nervous system lymphoma (pcnsl), in which it is the cornerstone of chemotherapy. objectives a selective and sensitive high-performance liquid chromatography-electrospray ionization-mass spectrometry method was developed...

full text

My Resources

Save resource for easier access later


Journal title:
iranian journal of pharmaceutical sciences

جلد ۱۲، شماره ۱، صفحات ۲۱-۳۴

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023