occupational exposure to welding fumes using different ventilation scenarios

Authors

mohammad javad jafari department of occupational health, faculty of health, university of shahid beheshti, tehran, iran.

behnaz shafiei department of occupational health, faculty of health, university of shahid beheshti, tehran, iran.

mansour rezazadeh azari department of occupational health, faculty of health, university of shahid beheshti, tehran, iran.

mohammad movahhedi department of occupational health, faculty of health, university of shahid beheshti, tehran, iran.

abstract

welders may suffer from welding fumes generated during the process if the ventilation systems are improperly applied. the objective of the present work was to study the mitigation of air pollutants at welding stations, using different ventilation scenarios. four air pollutants including iron oxide, respirable dust, ozone, and carbon monoxide were measured during four different ventilation scenarios using us osha and us niosh sampling and analysis methods. meantime, face velocity, volumetric airflow rates, duct velocity, static, and velocity pressures at different locations of the ventilation systems were also measured using bs 1042 standard methods. the paired t -test revealed that with p <0.05 there was a significant difference between occupational exposure to air pollutants in 4 different ventilation scenarios. the results also showed that when local and general ventilation systems were both on, the occupational exposure to iron oxide and carbon monoxide were below than their tlvs, but the exposure to the respirable dust in two welding stations and ozone levels in three welding stations were higher than their respective tlvs. the duct air velocity in three welding stations is higher and in eight stations lower than 10.1 m/s recommended by acgih. the mean value of volumetric airflow rates in all 11 stations were 34.7% of the required volumetric airflow rates based on standard ventilation systems recommended value. the applied general exhaust ventilation was only 35.5% of standard required value. the local exhaust ventilation is expected to mitigate the air pollutants to acceptable levels at welding stations.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Designing, Constructing and Installing a Local Exhaust Ventilation System to Minimize Welders\' Exposure to Welding Fumes

Background & Aims of the Study: Welder&rsquo;s exposure to welding fumes can cause occupational diseases. The current study sought to examine exposure to welding fumes among welders who work in the repair shop of Sarcheshmeh Copper Complex and design a local exhaust ventilation system to control exposure to welding fumes. Materials & Methods: This applied analytical study was co...

full text

Bronchial reactions to exposure to welding fumes.

OBJECTIVES To study the airway response and its mechanism to welding fumes in six welders with respiratory symptoms. METHODS Methacholine and welding challenge tests were carried out. The concentration of welding fumes during the exposure test was measured. On two subjects who developed bronchoconstricition to welding challenge, additional tests were carried out including prick, patch, and in...

full text

Occupational exposure to diesel exhaust fumes.

There is currently no OEL for diesel fumes in the UK. This study reports parallel measurements of airborne levels of diesel fume pollutants in nine distribution depots where diesel powered fork-lift trucks (FLTs) were in use. Correlations between individual pollutants are assessed as well as their spatial distribution. Samples were collected on board FLTs and at background positions at nine dis...

full text

Do existing empirical models for welding fumes estimate exposure to ultrafine particles among canadian welding apprentices?

To the Editor: W elders are at risk of a wide range of respiratory health problems, including bronchitis, airway irritation, and lung function changes.1–5 Despite short duration of exposure, an inception cohort study of apprentice welders in Quebec documented a significant respiratory function decline, incidence of welding-related respiratory symptoms suggestive of occupational asthma and sensi...

full text

Occupational exposure to welding gases during three welding processes and risk assessment by SQRCA method

Background: Hazardous chemical agents in the welding operation are a mixture of metal fumes and toxic gases, the inhalation of which causes adverse health effects among welders. The emission of gases in the workplace is a logical cause for concern regarding the potential development of respiratory disease. The aim of the present study was to determine the concentration values of gases discharge...

full text

Occupational exposure to manganese-containing welding fumes and pulmonary function indices among natural gas transmission pipeline welders.

OBJECTIVES The objectives of this study were to evaluate manganese (Mn)-containing welding fumes' exposure, assess urinary Mn as a biomarker for Mn exposure and investigate the correlation of Mn in air, total fumes and urinary Mn with pulmonary function indices in 118 welders and 37 unexposed controls from two regions in Iran, Assaluyeh and Borujen. METHODS Air samples were collected on mixed...