measurement of urinary cadmium in glazers using solid phase extraction followed by inductively coupled plasma atomic emission spectroscopy
Authors
abstract
glazers are exposed to a variety of heavy metals in the ceramic industry, causing adverse effect on the body systems. cadmium is one of the major raw materials for production of colored glazes. to evaluate occupational exposure to cadmium, spot urine samples were collected from 49 tile and pottery glazers n yazd city in 2010 at the beginning and end of the work shift (98 samples). totally, 55 office workers ere also evaluated as control group. samples were prepared using solid phase extraction followed by nductively coupled plasma atomic emission spectroscopy. all the participants filled out a self administered questionnaire comprises questions about work shift, kind of job, use of mask, ventilation, work history, overtime work, age, weight, and height. the lung function tests were performed in a standing position according to the american thoracic society recommendation on both control and cadmium exposed individuals. analysis of covariance (ancova) was used to evaluate the data. the mean values of cadmium levels before and after shift in study group was 3.88 and 10.85 μg/gcreatinine, respectively. the mean values of cadmium levels at the end of the work shift in the glazers urine amples was almost 3.53 times higher than the control group and 2.17 times higher than the acgih biological exposure indices (5 μg/g creatinine). in addition the lung functions of glazers was significantly lower than the office workers (p<0.001). exposure to cadmium in ceramic industry can lead to the reduction of respiratory capacity. hygienic behaviors such as using protective mask and working in efficient entilated workplaces can decrease the rate of occupational exposure to cadmium.
similar resources
Selective Separation and Preconcentration of trace Amounts of Gallium in Water and Rice Samples using Cloud Point Extraction and Determination by Inductively Coupled Plasma-Atomic Emission Spectrometry
In the present study a cloud-point extraction process using non-ionic surfactant Triton X-114 for selective extraction of gallium from aqueous solutions was developed. The method is based on the complex formation of Ga (III) with N, N′ -bis (salycilidene)-1, 2-phenylenediamine (salophen) as a chelating agent in buffer media of pH 5. After phase separation and dilution of the surfactant-rich pha...
full textScreening and Optimization of Microextraction of Pb(II) by Inductively Coupled Plasma-Atomic Emission Using Response Surface Methodology
Dispersive liquid–liquid microextraction (DLLME) combined with inductively coupled plasma-atomic emission spectrometry (ICP-AES) was applied for the determination of lead in different environmental water samples. Ammonium pyrrolidine dithiocarbamate (APDC), chloroform and ethanol were used as chelating agent, extraction solvent and disperser solvent, respectively. The effective parameters, such...
full textDetermination of sub-ppb cadmium in urine by solid-phase extraction and inductively coupled plasma-mass spectrometry.
In order to determine low levels of Cd in urine samples, we tried to remove Mo interference using ICP-MS with a dynamic reaction-cell technique, but failed due to the low sensitivity and the variance with the standards. We then performed solid-phase extraction (SPE) before the ICP-MS measurement. A commercially available chelating resin, NOBIAS PA-1, was used for SPE, and could effectively remo...
full textTime-resolved parametric studies of laser ablation using inductively coupled plasma atomic emission spectroscopy
The quantity of ablated mass and its composition strongly depend on the number of laser pulses and laser fluence at the sample target surface. For chemical analysis, thin-film deposition, cutting, and other laser-ablation applications, the quantity of mass removed vs. number of laser pulses is important. In addition, the composition of the vapor can be critical, for example, in providing accura...
full textpre-concentration and determination of platinum (iv) in water samples using chelating resin by inductively coupled plasma atomic emission spectroscopy (icp-aes)
a chelating resin is prepared by condensation polymerization of aniline with formaldehyde andcharacterized by ft-ir, elemental analysis and studied for the preconcentration and determination of traceplatinum ion from environmental water sample using inductively coupled plasma-atomic emission spectroscopy(icp-aes). the optimum ph value for sorption of the metal ions was 5. the maximum adsorption...
full textpre-concentration and determination of platinum (iv) in water samples using chelating resin by inductively coupled plasma atomic emission spectroscopy (icp-aes)
a chelating resin is prepared by condensation polymerization of aniline with formaldehyde andcharacterized by ft-ir, elemental analysis and studied for the preconcentration and determination of traceplatinum ion from environmental water sample using inductively coupled plasma-atomic emission spectroscopy(icp-aes). the optimum ph value for sorption of the metal ions was 5. the maximum adsorption...
full textMy Resources
Save resource for easier access later
Journal title:
international journal of occupational hygieneجلد ۴، شماره ۲، صفحات ۱۱-۱۶
Keywords
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023