the accuracy of single emulsion radiographic film in linear measurement of spiral tomography

Authors

arash dabbaghi

ali shokraneh

nastaran farhadi

abstract

background: conventional tomography used for evaluation of the small areas of the jaws provides acceptable information. it has some advantages of availability, less radiation dose and costin comparison to computed tomography (ct) and cone beam ct. double emulsion film usuallyused for taking tomograms requires less exposure than single emulsion film; on the other hand,the latter provides more sharpness and spatial resolution. the aim of this study was to comparediagnostic accuracy of these two kinds of films in the spiral tomography. materials and methods: in an experimental study, 20 lines (10 lines anterior and 10 lines posterior to the mental foramen) were selected on two dry human mandibles and tomographic images were taken from each line with and without metal marker by single and double emulsion films. for quantitative assessment, the mandibular width and length was identified and measuredon 80obtained tomograms. afterwards, the mandibles were sectioned on each line and theiractual width and height were measured. for each line, the data of tomograms were subtractedfrom gold standard as measurement error. these errors were divided into three groups: greaterthan +1 mm, between +1 mm and −1 mm and less than −1 mm. obtained data were analyzed bypearson chi‑square test (α=0/05). results: there was no significant difference between the single and double emulsion films, withand without markers in the measurement of both height and width of mandible ( p > 0.05). conclusion: the single emulsion film is not recommended to be used for taking the spiral tomogram. key words: emulsion, tomography, x‑ray film

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

The accuracy of single emulsion radiographic film in linear measurement of spiral tomography

BACKGROUND Conventional tomography used for evaluation of the small areas of the jaws provides acceptable information. It has some advantages of availability, less radiation dose and cost in comparison to computed tomography (CT) and cone beam CT. Double emulsion film usually used for taking tomograms requires less exposure than single emulsion film; on the other hand, the latter provides more ...

full text

Accuracy of mandibular vertical linear measurement in panoramic and tomography images

Introduction: The measurement precision of jaw is important for surgery or installing implants. Preimplant radiographs are important part of clinical evaluations before implant surgery. For choosing location, we should consider the important anatomical structures like mental foramen, inferior alveolar canal, nasal cavity and maxillary sinus.It is important to know the measurement accuracy of ra...

full text

comparative study of measurement accuracy of two digital spiral and digital linear tomography with cbct in implant treatment plan

statement of the problem in order to replace lost tooth of patients, we use dental implants which are common. therefore, accurate measuring of bone height and width before placing implants is necessary. the aim of this study is evaluating the accuracy of linear and spiral tomography in careful determination of implant site sizes in comparison with gold standard (cbct). material and methods this...

full text

the effect of task complexity on efl learners’ written task performance in terms of accuracy and complexity

هدف اصلی این تحقیق بررسی تاثیر افزایش میزان پیچیدگی تکالیف مکالمه محور بر دقت و صحت و پیچیدگی عملکرد نوشتاری زبان آموزان می باشد. بدین منظور، 50 نفر از دانش آموزان دختر در رده ی سنی 15 الی 18 سال درسطح pre-intermediate از طریق petو vhs تست به عنوان شرکت کنندگان در تحقیق انتخاب شدند و به دو گروه آزمایشی و کنترل بصورت اتفاقی تقسیم شدند. اعضای گروه آزمایشی دو تکلیف ساده و پیچیده را طی 2 جلسه انجام...

My Resources

Save resource for easier access later


Journal title:
dental research journal

جلد ۱۰، شماره ۲، صفحات ۰-۰

Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023